Skip to content
SafetyRecord logoSafetyRecord
THE BELDEN BRICK COMPANY, LLC - PLANTS (3 - 9)
$14,499
penalties
26
viol.
1
insp.

THE BELDEN BRICK COMPANY, LLC - PLANTS (3 - 9)

STATE ROUTE 39, Sugarcreek, OH 44681NAICS 327124

Inspections
1
Sep 1997 to Sep 1997 · 0 safety, 1 health
Violations
26
across 1 inspection
Penalties on record
$14,499
latest amounts in DOL records
By classification
Serious 24Willful 0Repeat 0Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 17, 1997Planned (H) · Partial scope, Health#121910798$14,49926 viol.

Inspection #121910798

Dates

Opened
Sep 17, 1997
Closing Conference Date
Sep 17, 1997
Contested
Dec 12, 1997
Closed
Feb 24, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
400

Violations and Penalties

Total Violations
26
Violation Types
24 serious, 2 other-than-serious
Initial Penalties
$30,375
Penalties on Record
$14,499
Site Address
State Route 39, Sugarcreek, OH 44681
Industry
327124

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Enforcement Outcome

Citation contest activity appears on Dec 12, 1997. Final orders are recorded through Nov 22, 1999. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC230 - 12mg/m³
Manganese Fume (as Mn)10.071mg/m³
Sample WeightQC230 - 3.187mg
Silica, Crystalline Quartz (Respirable Fraction)210 - 13%

Violations

Violation list (26 of 26 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
OSHA citation code: 19100022 B01
Serious12$1,125$439Apr 1, 1998--
01002A1910.23
OSHA citation code: 19100023 A08
Serious22$1,875$731Nov 18, 1997--
01002B1910.23
OSHA citation code: 19100023 A09
Serious15$0$0Dec 3, 1997--
010031910.23
OSHA citation code: 19100023 C01
Serious14$1,125$439Dec 3, 1997--
01004A1910.23
OSHA citation code: 19100023 D01 II
Serious12$1,125$731Dec 3, 1997--
01004B1910.23
OSHA citation code: 19100023 D01 III
Serious45$0$0Dec 3, 1997--
010051910.28
OSHA citation code: 19100028 A01
Serious11$1,500$585Nov 18, 1997--
01006A1910.38
OSHA citation code: 19100038 A01
Serious1300$1,125$439Apr 1, 1998--
010071910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious1717$1,875$731Dec 18, 1997--
01008A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G01
Serious118$1,875$731Apr 1, 1998--
01008B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I02 I
Serious56$0$0Dec 3, 1997--
01009A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 D
Serious19$1,875$731Dec 18, 1997--
01009B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 G01
Serious19$0$0Jul 1, 1998--
010101910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 II
Serious12$1,875$731Jul 1, 1998--
01011A1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06 I
Serious12$1,875$731Apr 1, 1998--
01011B1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 D04 I
Serious12$0$0Jul 1, 1998--
010121910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious11$1,875$731Dec 3, 1997--
010131910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B02
Serious12$1,500$585Dec 3, 1997--
010141910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Serious67$1,500$585Dec 3, 1997--
010151910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious23$1,875$539Dec 3, 1997--
010161910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious23$1,875$540Dec 3, 1997--
020011910.24
OSHA citation code: 19100024 D
Other11$0$0Dec 3, 1997--
020021910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Other12$0$0Nov 18, 1997--
03001A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious16$4,500$4,500Dec 21, 1997Dec 12, 1997Nov 22, 1999
03001B1910.1000
Air Contaminants
OSHA citation code: 19101000 C
Serious66$0$0Feb 19, 1998Dec 12, 1997Nov 22, 1999
03001C1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious16$0$0Feb 19, 1998Dec 12, 1997Nov 22, 1999
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.235 citations · $1,901
1910.219Mechanical Power-Transmission Apparatus4 citations · $2,249
1910.147The control of hazardous energy (lockout/tagout)3 citations · $1,462

Chemical exposure sampling

Samples
68
Substances
4
Inspections
1

Industry comparison

Violations per inspection
This employer26.0
Industry average3.3
Penalties per inspection
This employer$14,499
Industry average$2,354

Nonmetallic Mineral Product Manufacturing, 16,982 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in Sugarcreek, OH

All employers in Sugarcreek →