Skip to content
SafetyRecord logoSafetyRecord
THE DUMONT GROUP
$14,525
penalties
25
viol.
2
insp.

THE DUMONT GROUP

904 MAIN STREET, MONMOUTH, ME 04259

Inspections
2
Nov 1997 to Feb 2001 · 1 safety, 1 health
Violations
25
across 2 inspections
Penalties on record
$14,525
latest amounts in DOL records
By classification
Serious 20Willful 0Repeat 0Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 7, 2001Complaint (B) · Partial scope, Health#113789572$14,52525 viol.

Inspection #113789572

Dates

Opened
Feb 7, 2001
Closing Conference Date
Mar 27, 2001
Closed
May 3, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
150
Related Activity
1 complaint

Violations and Penalties

Total Violations
25
Violation Types
20 serious, 5 other-than-serious
Initial Penalties
$29,050
Penalties on Record
$14,525
Site Address
904 Main Street, Monmouth, ME 04259
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)60mg/m³
Beryllium and Beryllium Compounds (as Be)60mg/m³
Cadmium60 - 0.0001245mg/m³
Chromium, Metal and Insoluble Salts60.0085399 - 0.0173mg/m³
Cobalt, Metal, Dust and Fume (as Co)60 - 0.0006267mg/m³
Copper Fume (as Cu)60.0318 - 0.0637619mg/m³
Iron Oxide Fume64.7357574 - 13.23mg/m³
Lead, Inorganic (as Pb)60 - 0.0031034mg/m³
Manganese Fume (as Mn)60.1185662 - 1.0689656mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)60.001 - 0.0030014mg/m³
Nickel, Metal and Insoluble compounds (as Ni)60.0076 - 0.0174062mg/m³
Vanadium fume (as V2O5)60.0008493 - 0.0041264mg/m³
Zinc Oxide Fume60.0846408 - 0.2270705mg/m³

Violations

Violation list (25 of 25 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious22$1,750$875Apr 18, 2001--
01002A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I02 I
Serious14$1,750$875Apr 16, 2001--
01002B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D03
Serious13$0$0Apr 13, 2001--
010031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Serious21$1,750$875Apr 18, 2001--
010041910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious11$1,750$875Apr 18, 2001--
010051910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Serious114$1,750$875Apr 23, 2001--
010061910.134
Respiratory Protection
OSHA citation code: 19100134 H02 I
Serious414$1,050$525Apr 18, 2001--
010071910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Serious119$1,400$700Apr 13, 2001--
010081910.178
Powered Industrial Trucks
OSHA citation code: 19100178 M05 I
Serious219$1,050$525Apr 13, 2001--
010091910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 B08
Serious119$1,400$700Apr 18, 2001--
010101910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 G01 V
Serious28$1,400$700Apr 13, 2001--
010111910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious116$1,050$525Apr 18, 2001--
010121910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious214$1,750$875Apr 16, 2001--
010131910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious214$1,750$875Apr 18, 2001--
010141910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F01
Serious16$1,750$875Apr 13, 2001--
010151910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B02 III
Serious215$1,400$700Apr 16, 2001--
010161910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious11$1,050$525Apr 18, 2001--
010171910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious29$1,050$525Apr 16, 2001--
01018A1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Serious11$3,500$1,750May 13, 2001--
01018B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0Apr 23, 2001--
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other2180$700$350Apr 13, 2001--
020021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 Q07
Other11$0$0Apr 18, 2001--
020031910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other2-$0$0Apr 13, 2001--
020041910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Other2-$0$0Apr 23, 2001--
020051910.1200
Hazard Communication
OSHA citation code: 19101200 F05
Other1-$0$0Apr 16, 2001--
Nov 12, 1997Planned (H) · No Inspection scope, Safety#109788539$00 viol.

Inspection #109788539

Dates

Opened
Nov 12, 1997
Closing Conference Date
Not recorded
Closed
Nov 12, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
904 Main Street, Monmouth, ME 04259
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection3 citations · $2,275
1910.303Electrical - General Requirements2 citations · $0
1910.179Overhead and Gantry Cranes2 citations · $1,400

Chemical exposure sampling

Samples
78
Substances
13
Inspections
1

Other inspected employers in MONMOUTH, ME