Skip to content
SafetyRecord logoSafetyRecord
TIDEWATER ROOFING
$2,875
penalties
11
viol.
3
insp.

TIDEWATER ROOFING

900 BLAND BOULEVARD, Newport News, VA 23602NAICS 238160 Roofing Contractors

Inspections
3
Mar 2000 to Jan 2010 · 3 safety, 0 health
Violations
11
across 3 inspections
Penalties on record
$2,875
latest amounts in DOL records
By classification
Serious 6Willful 0Repeat 0Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 26, 2010Programmed Related (I) · Partial scope, Safety#314115163$2,1003 viol.

Inspection #314115163

Dates

Opened
Jan 26, 2010
Closing Conference Date
Jan 26, 2010
Closed
Apr 13, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$2,100
Penalties on Record
$2,100
Site Address
12896 Jefferson Ave., Newport News, VA 23608
Industry
238160 Roofing Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B10
Serious22$700$700Mar 12, 2010--
010021926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 B01
Serious22$700$700Mar 17, 2010--
010031926.1053
Ladders (Construction)
OSHA citation code: 19261053 B04
Serious12$700$700Mar 12, 2010--
Jun 19, 2007Programmed Related (I) · Partial scope, Safety#311175673$5252 viol.

Inspection #311175673

Dates

Opened
Jun 19, 2007
Closing Conference Date
Jun 21, 2007
Closed
Aug 7, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$875
Penalties on Record
$525
Site Address
900 Bland Boulevard, Newport News, VA 23602
Industry
238160 Roofing Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious13$875$525Aug 3, 2007--
020011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other23$0$0Aug 3, 2007--
Mar 2, 2000Planned (H) · Complete scope, Safety#303250914$2506 viol.

Inspection #303250914

Dates

Opened
Mar 2, 2000
Closing Conference Date
Mar 3, 2000
Closed
May 31, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 4 other-than-serious
Initial Penalties
$250
Penalties on Record
$250
Site Address
5400 Huntington Avenue, Newport News, VA 23607
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious12$125$125Apr 14, 2000--
010021926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 K01
Serious12$125$125Apr 14, 2000--
020011926.50
Medical services and first aid
OSHA citation code: 19260050 C
Other16$0$0May 13, 2000--
020021926.50
Medical services and first aid
OSHA citation code: 19260050 D01
Other16$0$0Apr 14, 2000--
020031926.51
Sanitation (Construction)
OSHA citation code: 19260051 A01 I
Other16$0$0Apr 14, 2000--
020041926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other11$0$0Apr 14, 2000--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.501Fall Protection - Duty to Have Fall Protection2 citations · $1,225
1926.404Electrical - Wiring Design and Protection (Construction)2 citations · $0
1926.50Medical services and first aid2 citations · $0

Industry comparison

Violations per inspection
This employer3.7
Industry average2.1
Penalties per inspection
This employer$958
Industry average$2,531

Specialty Trade Contractors, 552,116 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: roofing contractors reported 2.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.7%; NAICS 23816 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Newport News, VA

All employers in Newport News →