Skip to content
SafetyRecord logoSafetyRecord
TRULINE INDUSTRIES INC.
$6,000
penalties
21
viol.
2
insp.

TRULINE INDUSTRIES INC.

11715 CHILLICOTHE RD., Chesterland, OH 44026NAICS 333613 Mechanical Power Transmission Equipment Manufacturing

Inspections
2
Sep 1997 to Jan 2002 · 0 safety, 2 health
Violations
21
across 2 inspections
Penalties on record
$6,000
latest amounts in DOL records
By classification
Serious 18Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 24, 2002Complaint (B) · Partial scope, Health#304488067$6,00021 viol.

Inspection #304488067

Dates

Opened
Jan 24, 2002
Closing Conference Date
Jan 24, 2002
Closed
Apr 14, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
55
Related Activity
1 complaint

Violations and Penalties

Total Violations
21
Violation Types
18 serious, 3 other-than-serious
Initial Penalties
$12,000
Penalties on Record
$6,000
Site Address
11715 Chillicothe Rd., Chesterland, OH 44026
Industry
333613 Mechanical Power Transmission Equipment Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Cadmium30mg/m³
Chromium, Metal and Insoluble Salts30mg/m³
Cobalt, Metal, Dust and Fume (as Co)30mg/m³
Copper Fume (as Cu)30.0120894 - 1.0173562mg/m³
Iron Oxide Fume30mg/m³
Lead, Inorganic (as Pb)30.0096923 - 0.3166026mg/m³
Manganese Fume (as Mn)30mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
Nickel, Metal and Insoluble compounds (as Ni)30mg/m³
Vanadium fume (as V2O5)30mg/m³
Zinc Oxide Fume30mg/m³

Violations

Violation list (21 of 21 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G02
Serious155$750$375Mar 29, 2002--
010021910.303
OSHA citation code: 19100303 F
Serious145$750$375Mar 15, 2002--
01003A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious155$1,750$875Apr 5, 2002--
01003B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious1-$0$0Mar 20, 2002--
01003C1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious1-$0$0Mar 20, 2002--
01003D1910.1025
Lead
OSHA citation code: 19101025 L01 I
Serious145$0$0Apr 14, 2002--
01003E1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious1-$0$0Apr 14, 2002--
01004A1910.1025
Lead
OSHA citation code: 19101025 C01
Serious11$1,750$875Apr 14, 2002--
01004B1910.1025
Lead
OSHA citation code: 19101025 E01
Serious129$0$0May 14, 2002--
01004C1910.1025
Lead
OSHA citation code: 19101025 H01
Serious129$0$0May 14, 2002--
01004D1910.1025
Lead
OSHA citation code: 19101025 H02 II
Serious129$0$0Mar 20, 2002--
010051910.1025
Lead
OSHA citation code: 19101025 D01 II
Serious129$1,750$875Apr 5, 2002--
010061910.1025
Lead
OSHA citation code: 19101025 E03 I
Serious129$1,750$875Apr 14, 2002--
01007A1910.1025
Lead
OSHA citation code: 19101025 G01
Serious128$1,750$875Mar 20, 2002--
01008B1910.1025
Lead
OSHA citation code: 19101025 I04 III
Serious128$0$0Mar 20, 2002--
01008C1910.1025
Lead
OSHA citation code: 19101025 M02 I
Serious128$0$0Mar 20, 2002--
01009A1910.1025
Lead
OSHA citation code: 19101025 J01 I
Serious128$1,750$875Mar 25, 2002--
01009B1910.1025
Lead
OSHA citation code: 19101025 J02 IA
Serious128$0$0Mar 29, 2002--
020011910.132
General requirements
OSHA citation code: 19100132 D02
Other145$0$0Apr 5, 2002--
020021910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other144$0$0Mar 15, 2002--
020031910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 C01 I
Other155$0$0Mar 15, 2002--
Sep 9, 1997Planned (H) · No Inspection scope, Health#300110210$00 viol.

Inspection #300110210

Dates

Opened
Sep 9, 1997
Closing Conference Date
Sep 9, 1997
Closed
Sep 10, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
39

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
11715 Chillicothe Rd., Chesterland, OH 44026
Industry
333613 Mechanical Power Transmission Equipment Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead12 citations · $4,375
1910.1200Hazard Communication4 citations · $875
1910.242Hand and Portable Powered Tools and Equipment, General1 citation · $0

Chemical exposure sampling

Samples
39
Substances
13
Inspections
1

Industry comparison

Violations per inspection
This employer10.5
Industry average3.4
Penalties per inspection
This employer$3,000
Industry average$2,141

Machinery Manufacturing, 17,994 employers with OSHA inspections. Arithmetic from DOL records.