Skip to content
SafetyRecord logoSafetyRecord
TWINING MASONRY
$3,025
penalties
17
viol.
1
insp.

TWINING MASONRY

SHADY LANE ROAD, CHINCHILLA, PA 18410NAICS 236220 Commercial and Institutional Building Construction

Inspections
1
Feb 1993 to Feb 1993 · 1 safety, 0 health
Violations
17
across 1 inspection
Penalties on record
$3,025
latest amounts in DOL records
By classification
Serious 15Willful 0Repeat 0Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 3, 1993Planned (H) · Complete scope, Safety#106471873$3,02517 viol.

Inspection #106471873

Dates

Opened
Feb 3, 1993
Closing Conference Date
Feb 3, 1993
Closed
Mar 20, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
17
Violation Types
15 serious, 2 other-than-serious
Initial Penalties
$5,850
Penalties on Record
$3,025
Site Address
Shady Lane Road, Chinchilla, PA 18410
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (17 of 17 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.59
Hazard Communication
OSHA citation code: 19260059 E01
Serious12$600$400Apr 12, 1993--
01001B1926.59
Hazard Communication
OSHA citation code: 19260059 F05 II
Serious12$0$0Apr 12, 1993--
01001C1926.59
Hazard Communication
OSHA citation code: 19260059 G01
Serious12$0$0Apr 12, 1993--
01001D1926.59
Hazard Communication
OSHA citation code: 19260059 H
Serious12$0$0Apr 12, 1993--
010021926.152
OSHA citation code: 19260152 A01
Serious12$800$400Mar 15, 1993--
01003A1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious12$1,400$700Mar 15, 1993--
01003B1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 J01 III
Serious12$0$0Mar 15, 1993--
01003C1926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Serious12$0$0Apr 12, 1993--
01003D1926.21
Safety Training and Education
OSHA citation code: 19260021 B02
Serious12$0$0Apr 12, 1993--
01004A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A06
Serious11$1,400$700Mar 28, 1993--
01004B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A13
Serious11$0$0Mar 28, 1993--
01004C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A14
Serious11$0$0Mar 28, 1993--
010051926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D10
Serious11$1,050$525Mar 28, 1993--
01006A1926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01
Serious12$600$300Mar 15, 1993--
01006B1926.1052
Stairways (Construction)
OSHA citation code: 19261052 C05
Serious12$0$0Mar 15, 1993--
020011926.300
General requirements
OSHA citation code: 19260300 B01
Other12$0$0Mar 15, 1993--
020021926.301
Hand Tools
OSHA citation code: 19260301 D
Other12$0$0Mar 18, 1993--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.59Hazard Communication4 citations · $400
1926.451Scaffolding - General Requirements4 citations · $1,225
1926.1052Stairways (Construction)2 citations · $300

Industry comparison

Violations per inspection
This employer17.0
Industry average1.5
Penalties per inspection
This employer$3,025
Industry average$1,286

Construction of Buildings, 202,702 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in CHINCHILLA, PA

All employers in CHINCHILLA →