Skip to content
SafetyRecord logoSafetyRecord
U.S. POSTAL SERVICE
$3,556
penalties
20
viol.
7
insp.

U.S. POSTAL SERVICE

680 STATE HWY # L30, TRENTON, NJ 08650

Inspections
7
Nov 1987 to Feb 2025 · 3 safety, 4 health
Violations
20
across 7 inspections
Penalties on record
$3,556
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 21, 2025Complaint (B) · Partial scope, Safety#348055534$01 viol.

Inspection #348055534

Dates

Opened
Feb 21, 2025
Closing Conference Date
May 21, 2025
Final Order
Jun 4, 2025
Closed
Jun 5, 2025

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
654
Related Activity
6 complaints

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
680 Us Hwy 130, Trenton, NJ 08650
Industry
491110

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B05
Other16$0$0Jun 5, 2025-Jun 4, 2025
Nov 21, 2023Planned (H) · Complete scope, Safety#347120776$00 viol.

Inspection #347120776

Dates

Opened
Nov 21, 2023
Closing Conference Date
Nov 21, 2023
Closed
Jan 9, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
800

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
680 Us Highway 130, Trenton, NJ 08650
Industry
491110

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Nov 21, 2011Complaint (B) · Partial scope, Health#315978494$1,9801 viol.

Inspection #315978494

Dates

Opened
Nov 21, 2011
Closing Conference Date
Nov 21, 2011
Contested
Apr 27, 2012
Final Order
Oct 15, 2012
Closed
Oct 31, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
797
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$3,300
Penalties on Record
$1,980
Site Address
680 Us Highway 130, Trenton, NJ 08650
Industry
491110

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IVA
Serious3797$3,300$1,980Apr 9, 2012Apr 27, 2012Oct 15, 2012
Feb 3, 1999Complaint (B) · Partial scope, Health#301323325$1,5764 viol.

Inspection #301323325

Dates

Opened
Feb 3, 1999
Closing Conference Date
Feb 12, 1999
Closed
Apr 5, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
811
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$2,250
Penalties on Record
$1,576
Site Address
680 State Hwy # L30, Trenton, NJ 08650
Industry
491110

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other12$1,125$788Feb 23, 1999--
01001B1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other12$0$0Feb 23, 1999--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J01 I
Other13$1,125$788Feb 23, 1999--
020011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Other12$0$0Apr 5, 1999--
Jun 30, 1992Complaint (B) · Partial scope, Health#106922693$00 viol.

Inspection #106922693

Dates

Opened
Jun 30, 1992
Closing Conference Date
Jun 30, 1992
Closed
Jul 8, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
2,975
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
680 State Hwy # L30, Trenton, NJ 08650
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Sep 14, 1988Programmed Other (K) · Complete scope, Safety#100234285$014 viol.

Inspection #100234285

Dates

Opened
Sep 14, 1988
Closing Conference Date
Sep 14, 1988
Closed
Oct 19, 1989

Inspection

Advance Notice
Yes
Owner Type
Private
Union Status
Yes
Number of Employees
2,984

Violations and Penalties

Total Violations
14
Violation Types
8 serious, 6 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
680 State Hwy # L30, Trenton, NJ 08650
Industry
Not classified in OSHA's inspection record.

Programmed Other Inspection: This inspection record is categorized as a programmed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (7 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 B02
Serious110$0$0Sep 25, 1989--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Serious17$0$0Jan 31, 1989--
010031910.176
Handling Materials - General
OSHA citation code: 19100176 B
Serious16$0$0Oct 26, 1988--
010041910.176
Handling Materials - General
OSHA citation code: 19100176 C
Serious350$0$0Nov 19, 1988--
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious120$0$0Oct 22, 1988--
010061910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 IIB
Serious31$0$0Oct 22, 1988--
010071910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious12$0$0Oct 22, 1988--

Showing the 7 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Nov 10, 1987Unprogrammed Other (J) · Partial scope, Health#100525021$00 viol.

Inspection #100525021

Dates

Opened
Nov 10, 1987
Closing Conference Date
Mar 28, 1988
Closed
Apr 8, 1988

Inspection

Advance Notice
Yes
Owner Type
Private
Union Status
Yes
Number of Employees
850

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
680 State Hwy # L30, Trenton, NJ 08650
Industry
Not classified in OSHA's inspection record.

Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Cadmium Fume (as Cd)20mg/m³
Chromium, Metal and Insoluble Salts20 - 0.0127mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20mg/m³
Iron Oxide Fume20 - 0.8234mg/m³
Lead, Inorganic (as Pb)20 - 0.0254mg/m³
Manganese Fume (as Mn)20 - 0.0044mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)10mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20 - 0.0163mg/m³
Particulates not otherwise regulated (Respirable Fraction)14.78mg/m³
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20 - 0.0514mg/m³
Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment5 citations · $2,768
1910.22Walking-Working Surfaces - General Requirements3 citations · $0
1910.176Handling Materials - General2 citations · $0

Chemical exposure sampling

Samples
26
Substances
14
Inspections
1

Other inspected employers in TRENTON, NJ

All employers in TRENTON →