Skip to content
SafetyRecord logoSafetyRecord
WEBB METALS, LTD.
$650
penalties
24
viol.
5
insp.

WEBB METALS, LTD.

1305 PHILADELPHIA CHURCH ROAD, Dallas, NC 28034NAICS 423930 Recyclable Material Merchant Wholesalers

Inspections
5
Jul 1996 to Feb 2011 · 1 safety, 4 health
Violations
24
across 5 inspections
Penalties on record
$650
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 19

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 22, 2011Planned (H) · Complete scope, Health#315435354$2005 viol.

Inspection #315435354

Dates

Opened
Feb 22, 2011
Closing Conference Date
Feb 23, 2011
Closed
Mar 31, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
5
Violation Types
2 serious, 3 other-than-serious
Initial Penalties
$200
Penalties on Record
$200
Site Address
1305 Philadelphia Church Road, Dallas, NC 28034
Industry
423930 Recyclable Material Merchant Wholesalers

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
OSHA citation code: 19100106 B06
Serious11$100$100Mar 25, 2011--
010021910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious11$100$100Mar 25, 2011--
020011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other11$0$0Apr 15, 2011--
020021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Other11$0$0Mar 25, 2011--
020031910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Other12$0$0Mar 25, 2011--
Apr 25, 2007Planned (H) · Complete scope, Health#311028450$09 viol.

Inspection #311028450

Dates

Opened
Apr 25, 2007
Closing Conference Date
Apr 25, 2007
Closed
Jun 26, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
29

Violations and Penalties

Total Violations
9
Violation Types
9 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1305 Philadelphia Church Road, Dallas, NC 28034
Industry
423930 Recyclable Material Merchant Wholesalers

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
OSHA citation code: 19100022 D01
Other14$0$0May 23, 2007--
010021910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Other13$0$0May 23, 2007--
010031910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Other110$0$0May 23, 2007--
010041910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other110$0$0May 23, 2007--
010051910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Other110$0$0May 23, 2007--
010061910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L06
Other15$0$0Jun 21, 2007--
010071910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other11$0$0May 23, 2007--
010081910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Other12$0$0May 23, 2007--
010091910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Other12$0$0May 23, 2007--
Apr 24, 2002Planned (H) · Complete scope, Health#305493397$03 viol.

Inspection #305493397

Dates

Opened
Apr 24, 2002
Closing Conference Date
Apr 24, 2002
Closed
Jun 26, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1305 Philadelphia Church Road, Dallas, NC 28034
Industry
423930 Recyclable Material Merchant Wholesalers

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Other11$0$0Jun 20, 2002--
010021910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other12$0$0Jun 20, 2002--
010031910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Other12$0$0Jun 20, 2002--
Mar 10, 1999Planned (H) · Complete scope, Health#302648894$1005 viol.

Inspection #302648894

Dates

Opened
Mar 10, 1999
Closing Conference Date
Mar 10, 1999
Closed
Apr 19, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13

Violations and Penalties

Total Violations
5
Violation Types
1 serious, 4 other-than-serious
Initial Penalties
$100
Penalties on Record
$100
Site Address
1305 Philadelphia Church Road, Dallas, NC 28034
Industry
423930 Recyclable Material Merchant Wholesalers

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
OSHA citation code: 19100023 C01
Serious22$100$100Apr 12, 1999--
020011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 II
Other12$0$0Apr 12, 1999--
020021910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06 II
Other12$0$0Apr 12, 1999--
020031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other513$0$0Apr 12, 1999--
020041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Other11$0$0Apr 12, 1999--
Jul 25, 1996Complaint (B) · Partial scope, Safety#301515599$3502 viol.

Inspection #301515599

Dates

Opened
Jul 25, 1996
Closing Conference Date
Aug 5, 1996
Closed
Sep 19, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
21
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$350
Penalties on Record
$350
Site Address
1305 Philadelphia Church Road, Dallas, NC 28034
Industry
423930 Recyclable Material Merchant Wholesalers

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 I
Serious11$350$350Sep 3, 1996--
01001B1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C07 IV
Serious12$0$0Sep 3, 1996--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147The control of hazardous energy (lockout/tagout)4 citations · $350
1910.157Portable Fire Extinguishers4 citations · $0
1910.1200Hazard Communication3 citations · $0

Industry comparison

Violations per inspection
This employer4.8
Industry average2.6
Penalties per inspection
This employer$130
Industry average$2,642

Merchant Wholesalers, Durable Goods, 24,720 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: recyclable material merchant wholesalers reported 3.7 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.0%; NAICS 42393 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Dallas, NC