Skip to content
SafetyRecord logoSafetyRecord
WHITE OAK CONSTRUCTION COMPANY, INC.
$12,630
penalties
59
viol.
1
insp.

WHITE OAK CONSTRUCTION COMPANY, INC.

7 WEST MAIN STREET, PLAINVILLE, CT 06062

Inspections
1
Jan 1990 to Jan 1990 · 0 safety, 1 health
Violations
59
across 1 inspection
Penalties on record
$12,630
latest amounts in DOL records
By classification
Serious 49Willful 0Repeat 0Other 10

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 11, 1990Complaint (B) · Partial scope, Health#100774959$12,63059 viol.

Inspection #100774959

Dates

Opened
Jan 11, 1990
Closing Conference Date
Jan 11, 1990
Contested
Apr 2, 1990
Final Order
Mar 6, 1991
Closed
Sep 24, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
50
Related Activity
2 complaints

Violations and Penalties

Total Violations
59
Violation Types
49 serious, 10 other-than-serious
Initial Penalties
$21,060
Penalties on Record
$12,630
Site Address
7 West Main Street, Plainville, CT 06062
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Beryllium and Beryllium Compounds (as Be)40mg/m³
Cadmium Fume (as Cd)40mg/m³
Chromium, Metal and Insoluble Salts40 - 0.0023mg/m³
Cobalt, Metal, Dust and Fume (as Co)40mg/m³
Copper Fume (as Cu)40 - 0.0754mg/m³
Iron Oxide Fume40 - 9.8734mg/m³
Lead, Inorganic (as Pb)140 - 9.3mg/m³
Manganese Fume (as Mn)40 - 0.0893mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40 - 0.0031mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40mg/m³
Vanadium fume (as V2O5)40mg/m³
Zinc Oxide Fume40 - 0.004mg/m³

Violations

Violation list (59 of 59 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.22
OSHA citation code: 19100022 A02
Serious19$360$250Mar 23, 1990Apr 2, 1990Mar 6, 1991
01001B1910.94
Ventilation
OSHA citation code: 19100094 C03 IV
Serious19$0$0May 22, 1990Apr 2, 1990Mar 6, 1991
010021910.23
OSHA citation code: 19100023 A08
Serious234$360$225Apr 22, 1990Apr 2, 1990Mar 6, 1991
010031910.28
OSHA citation code: 19100028 A01
Serious12$540$400Apr 22, 1990Apr 2, 1990Mar 6, 1991
01004A1910.37
OSHA citation code: 19100037 Q01
Serious134$360$250Apr 5, 1990Apr 2, 1990Mar 6, 1991
01004B1910.37
OSHA citation code: 19100037 G01
Serious234$0$0Mar 22, 1990Apr 2, 1990Mar 6, 1991
01005A1910.94
Ventilation
OSHA citation code: 19100094 C03 IB
Serious13$360$250May 22, 1990Apr 2, 1990Mar 6, 1991
01005B1910.94
Ventilation
OSHA citation code: 19100094 C07 IIIB
Serious13$0$0Apr 22, 1990Apr 2, 1990Mar 6, 1991
01005C1910.106
OSHA citation code: 19100106 E02 IVA
Serious13$0$0Mar 22, 1990Apr 2, 1990Mar 6, 1991
01005D1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 IV
Serious13$0$0Apr 22, 1990Apr 2, 1990Mar 6, 1991
01005E1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Serious13$0$0Apr 22, 1990Apr 2, 1990Mar 6, 1991
010061910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious28$720$400May 22, 1990Apr 2, 1990Mar 6, 1991
010071910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G01
Serious28$540$400May 26, 1990Apr 2, 1990Mar 6, 1991
010081910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I02 IIA
Serious28$540$400May 26, 1990Apr 2, 1990Mar 6, 1991
010091910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I03
Serious28$450$300Apr 26, 1990Apr 2, 1990Mar 6, 1991
010101910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Serious28$540$400May 23, 1990Apr 2, 1990Mar 6, 1991
010111910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C06
Serious134$720$400May 23, 1990Apr 2, 1990Mar 6, 1991
01012A1910.132
General requirements
OSHA citation code: 19100132 A
Serious134$630$350Mar 26, 1990Apr 2, 1990Mar 6, 1991
01012B1910.132
General requirements
OSHA citation code: 19100132 A
Serious11$0$0Mar 30, 1990Apr 2, 1990Mar 6, 1991
01012C1910.132
General requirements
OSHA citation code: 19100132 A
Serious11$0$0Mar 24, 1990Apr 2, 1990Mar 6, 1991
010131910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious231$720$400Mar 24, 1990Apr 2, 1990Mar 6, 1991
010141910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious134$540$400Mar 24, 1990Apr 2, 1990Mar 6, 1991
01015A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious134$540$400Mar 24, 1990Apr 2, 1990Mar 6, 1991
01015B1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious134$0$0Mar 24, 1990Apr 2, 1990Mar 6, 1991
010161910.303
OSHA citation code: 19100303 G02 I
Serious11$270$150Mar 24, 1990Apr 2, 1990Mar 6, 1991
010171910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 A02 IIIG
Serious134$450$300Mar 26, 1990Apr 2, 1990Mar 6, 1991
010181910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Serious134$450$350Mar 24, 1990Apr 2, 1990Mar 6, 1991
010191910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G01 III
Serious134$450$300Mar 24, 1990Apr 2, 1990Mar 6, 1991
010201910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G02 II
Serious134$450$300Mar 26, 1990Apr 2, 1990Mar 6, 1991
010211910.1025
Lead
OSHA citation code: 19101025 C01
Serious38$810$155Apr 6, 1990Apr 2, 1990Mar 6, 1991
010221910.1025
Lead
OSHA citation code: 19101025 D01 II
Serious38$810$450May 23, 1990Apr 2, 1990Mar 6, 1991
010231910.1025
Lead
OSHA citation code: 19101025 E01
Serious28$720$400May 25, 1990Apr 2, 1990Mar 6, 1991
010241910.1025
Lead
OSHA citation code: 19101025 E03 I
Serious18$540$400Apr 23, 1990Apr 2, 1990Mar 6, 1991
01025A1910.1025
Lead
OSHA citation code: 19101025 F01
Serious38$720$400Mar 30, 1990Apr 2, 1990Mar 6, 1991
01025B1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious33$0$0Apr 23, 1990Apr 2, 1990Mar 6, 1991
01025C1910.1025
Lead
OSHA citation code: 19101025 F03 II
Serious18$0$0Apr 26, 1990Apr 2, 1990Mar 6, 1991
010261910.1025
Lead
OSHA citation code: 19101025 G01
Serious18$720$400Apr 2, 1990Apr 2, 1990Mar 6, 1991
010271910.1025
Lead
OSHA citation code: 19101025 H01
Serious18$720$400Apr 2, 1990Apr 2, 1990Mar 6, 1991
010281910.1025
Lead
OSHA citation code: 19101025 I01
Serious18$630$350Mar 27, 1990Apr 2, 1990Mar 6, 1991
010291910.1025
Lead
OSHA citation code: 19101025 I02 I
Serious18$720$400Sep 26, 1990Apr 2, 1990Mar 6, 1991
010301910.1025
Lead
OSHA citation code: 19101025 I03 II
Serious18$720$400Sep 26, 1990Apr 2, 1990Mar 6, 1991
010311910.1025
Lead
OSHA citation code: 19101025 I03 III
Serious1-$720$400Mar 27, 1990Apr 2, 1990Mar 6, 1991
010321910.1025
Lead
OSHA citation code: 19101025 I04 I
Serious18$720$400Sep 26, 1990Apr 2, 1990Mar 6, 1991
01033A1910.1025
Lead
OSHA citation code: 19101025 J02 I
Serious18$720$400Apr 26, 1990Apr 2, 1990Mar 6, 1991
01033B1910.1025
Lead
OSHA citation code: 19101025 J03 IB
Serious18$0$0Apr 26, 1990Apr 2, 1990Mar 6, 1991
010341910.1025
Lead
OSHA citation code: 19101025 L01 II
Serious38$720$400Apr 16, 1990Apr 2, 1990Mar 6, 1991
010351910.1025
Lead
OSHA citation code: 19101025 M02 I
Serious38$630$350Mar 26, 1990Apr 2, 1990Mar 6, 1991
01036A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious534$450$300Mar 24, 1990Apr 2, 1990Mar 6, 1991
01036B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious534$0$0Mar 24, 1990Apr 2, 1990Mar 6, 1991
020011904.2
OSHA citation code: 19040002 A
Other150$0$0Apr 26, 1990Apr 2, 1990Mar 6, 1991
020021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Other38$0$0May 26, 1990Apr 2, 1990Mar 6, 1991
020031910.95
Occupational Noise Exposure
OSHA citation code: 19100095 L01
Other38$0$0Mar 27, 1990Apr 2, 1990Mar 6, 1991
020041910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Other13$0$0Mar 24, 1990Apr 2, 1990Mar 6, 1991
020051910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G03
Other13$0$0Mar 24, 1990Apr 2, 1990Mar 6, 1991
020061910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 J04 IIIG
Other13$0$0Mar 24, 1990Apr 2, 1990Mar 6, 1991
020071910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Other11$0$0Mar 24, 1990Apr 2, 1990Mar 6, 1991
020081910.252
General requirements
OSHA citation code: 19100252 D02 II
Other15$0$0Mar 27, 1990Apr 2, 1990Mar 6, 1991
020091910.252
General requirements
OSHA citation code: 19100252 E02 III
Other134$0$0Mar 24, 1990Apr 2, 1990Mar 6, 1991
020101910.1001
Asbestos
OSHA citation code: 19101001 F01
Other134$0$0May 26, 1990Apr 2, 1990Mar 6, 1991
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead17 citations · $5,705
1910.95Occupational Noise Exposure7 citations · $1,900
1910.107Spray Finishing Using Flammable and Combustible Materials6 citations · $400

Chemical exposure sampling

Samples
62
Substances
13
Inspections
1

Other inspected employers in PLAINVILLE, CT

All employers in PLAINVILLE →