WIRE & CABLE SPECIALTIES, INC.
$6,995
penalties
35
viol.
3
insp.

WIRE & CABLE SPECIALTIES, INC.

205 CARTER DRIVE, WEST CHESTER, PA 19382NAICS 332618 Other Fabricated Wire Product Manufacturing

Inspections
3
Nov 1993 to Mar 2003 · 2 safety, 1 health
Violations
35
across 3 inspections
Penalties on record
$6,995
latest amounts in DOL records
By classification
Serious 31Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 13, 2003Planned (H) · Complete scope, Health#102945524$2,73024 viol.

Inspection #102945524

Dates

Opened
Mar 13, 2003
Closing Conference Date
Mar 26, 2003
Closed
Jul 14, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
70

Violations and Penalties

Total Violations
24
Violation Types
21 serious, 3 other-than-serious
Initial Penalties
$4,200
Penalties on Record
$2,730
Site Address
205 Carter Drive, West Chester, PA 19382
Industry
332618 Other Fabricated Wire Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (16 of 24 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious26$700$500May 20, 2003--
01001B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious26$0$0May 20, 2003--
01001C1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G01
Serious26$0$0May 20, 2003--
01001D1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Serious26$0$0May 20, 2003--
01001E1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 L01
Serious26$0$0May 20, 2003--
010021910.111
Storage and Handling of Anhydrous Ammonia
OSHA citation code: 19100111 C07
Serious170$875$500Jun 30, 2003--
01003A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C01
Serious170$525$500May 20, 2003--
01003B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C02
Serious160$0$0May 20, 2003--
01004A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious16$700$500Jun 30, 2003--
01004B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 IID
Serious16$0$0Jun 30, 2003--
01004C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious16$0$0Jun 30, 2003--
01004D1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IA
Serious12$0$0Jun 30, 2003--
01004E1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IB
Serious119$0$0Jun 30, 2003--
01004F1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IC
Serious120$0$0Jun 30, 2003--
01005A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious13$700$500May 20, 2003--
01005B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious13$0$0May 20, 2003--

Showing the 16 violations listed first by citation identifier. This inspection has 24 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 29, 1998Planned (H) · No Inspection scope, Safety#301451464$00 viol.

Inspection #301451464

Dates

Opened
Oct 29, 1998
Closing Conference Date
Oct 29, 1998
Closed
Oct 29, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
205 Carter Drive, West Chester, PA 19382
Industry
332618 Other Fabricated Wire Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Nov 9, 1993Planned (H) · Complete scope, Safety#17713207$4,26511 viol.

Inspection #17713207

Dates

Opened
Nov 9, 1993
Closing Conference Date
Nov 9, 1993
Closed
Mar 30, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
34

Violations and Penalties

Total Violations
11
Violation Types
10 serious, 1 other-than-serious
Initial Penalties
$7,750
Penalties on Record
$4,265
Site Address
205 Carter Drive, West Chester, PA 19382
Industry
332618 Other Fabricated Wire Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 L01
Serious110$750$410Mar 18, 1994--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious15$1,250$690Apr 10, 1994--
010031910.176
Handling Materials - General
OSHA citation code: 19100176 B
Serious110$750$415Mar 18, 1994--
01004A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious110$1,250$685Apr 25, 1994--
01004B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious110$0$0Apr 25, 1994--
01004C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F01
Serious110$0$0Apr 25, 1994--
010051910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious210$1,250$690Apr 10, 1994--
010061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious110$1,250$685Apr 10, 1994--
01007A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious110$1,250$690Apr 10, 1994--
01007B1910.1200
Hazard Communication
OSHA citation code: 19101200 H01 I
Serious110$0$0Apr 10, 1994--
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other134$0$0Mar 25, 1994--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147Control of Hazardous Energy (Lockout/Tagout)7 citations · $1,190
1910.219Mechanical Power-Transmission Apparatus6 citations · $1,185
1910.1200Hazard Communication6 citations · $920

Industry comparison

Violations per inspection
This employer11.7
Industry average3.3
Penalties per inspection
This employer$2,332
Industry average$2,301

Fabricated Metal Product Manufacturing, 45,875 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: spring and wire product manufacturing reported 3.2 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 10.7%; NAICS 33261 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source