Skip to content
SafetyRecord logoSafetyRecord
WRIGHTSVILLE BUILDERS, INC.
$1,100
penalties
37
viol.
7
insp.

WRIGHTSVILLE BUILDERS, INC.

2704 EXCHANGE DRIVE, WILMINGTON, NC 28405NAICS 236220 Commercial and Institutional Building Construction

Inspections
7
Oct 1998 to Jun 2005 · 7 safety, 0 health
Violations
37
across 7 inspections
Penalties on record
$1,100
latest amounts in DOL records
By classification
Serious 25Willful 0Repeat 0Other 12

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 7, 2005Planned (H) · Complete scope, Safety#308778901$2007 viol.

Inspection #308778901

Dates

Opened
Jun 7, 2005
Closing Conference Date
Jun 7, 2005
Closed
Sep 1, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10

Violations and Penalties

Total Violations
7
Violation Types
2 serious, 5 other-than-serious
Initial Penalties
$600
Penalties on Record
$200
Site Address
2505 S 17th St., Wilmington, NC 28401
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 I02 I
Other11$350$0Jul 25, 2005--
01002A1926.307
Mechanical Power-Transmission Apparatus
OSHA citation code: 19260307 D01
Serious11$250$200Jul 25, 2005--
01002B1926.307
Mechanical Power-Transmission Apparatus
OSHA citation code: 19260307 E01 I
Serious11$0$0Jul 25, 2005--
020011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other11$0$0Jul 22, 2005--
020021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 E01
Other11$0$0Jul 25, 2005--
020031926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G01 III
Other11$0$0Jul 25, 2005--
020041926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 III
Other11$0$0Jul 25, 2005--
Feb 12, 2003Planned (H) · Complete scope, Safety#306140864$00 viol.

Inspection #306140864

Dates

Opened
Feb 12, 2003
Closing Conference Date
Feb 12, 2003
Closed
Feb 19, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
5329 Oleander Drive, Wilmington, NC 28403
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 15, 2002Planned (H) · Complete scope, Safety#305410490$1608 viol.

Inspection #305410490

Dates

Opened
Jul 15, 2002
Closing Conference Date
Jul 15, 2002
Closed
Nov 25, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
8
Violation Types
6 serious, 2 other-than-serious
Initial Penalties
$200
Penalties on Record
$160
Site Address
Military Cut Off Rd., Wilmington, NC 28403
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B02
Serious22$100$80Aug 13, 2002--
01001B1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIE
Serious22$0$0Aug 13, 2002--
01002A1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious11$100$80Aug 13, 2002--
01002B1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 B02
Serious11$0$0Aug 13, 2002--
01002C1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 B04
Serious11$0$0Aug 13, 2002--
01002D1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 B09
Serious11$0$0Aug 13, 2002--
020011910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Other14$0$0Aug 13, 2002--

Showing the 7 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Dec 19, 2000Planned (H) · No Inspection scope, Safety#303832430$00 viol.

Inspection #303832430

Dates

Opened
Dec 19, 2000
Closing Conference Date
Dec 19, 2000
Closed
Dec 20, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Military Cut Off Rd., Wilmington, NC 28403
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 7, 1999Referral (C) · Partial scope, Safety#302868708$1758 viol.

Inspection #302868708

Dates

Opened
Jul 7, 1999
Closing Conference Date
Jul 7, 1999
Closed
Oct 21, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10
Related Activity
1 referral

Violations and Penalties

Total Violations
8
Violation Types
5 serious, 3 other-than-serious
Initial Penalties
$525
Penalties on Record
$175
Site Address
2709 Market St, Wilmington, NC 28401
Industry
236220 Commercial and Institutional Building Construction

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (7 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B01
Serious16$175$175Aug 16, 1999--
01001B1926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Serious16$0$0Aug 16, 1999--
01001C1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 A02
Serious16$0$0Aug 16, 1999--
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 A02
Serious16$175$0Aug 16, 1999--
010031926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B14
Serious16$175$0Aug 16, 1999--
020011926.51
Sanitation (Construction)
OSHA citation code: 19260051 A04
Other17$0$0Aug 16, 1999--
020021926.150
Fire Protection (Construction)
OSHA citation code: 19260150 C01 I
Other17$0$0Aug 16, 1999--

Showing the 7 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Feb 26, 1999Unprogrammed Related (G) · Partial scope, Safety#302636915$25010 viol.

Inspection #302636915

Dates

Opened
Feb 26, 1999
Closing Conference Date
Feb 26, 1999
Closed
Jun 24, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1
Related Activity
1 referral

Violations and Penalties

Total Violations
10
Violation Types
8 serious, 2 other-than-serious
Initial Penalties
$250
Penalties on Record
$250
Site Address
2704 Exchange Drive, Wilmington, NC 28405
Industry
236220 Commercial and Institutional Building Construction

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (7 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.307
Mechanical Power-Transmission Apparatus
OSHA citation code: 19260307 D01
Serious11$125$125Apr 19, 1999--
01002A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02
Serious11$125$125Apr 19, 1999--
01002B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02 II
Serious11$0$0Apr 19, 1999--
01002C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C03
Serious11$0$0Apr 19, 1999--
01002D1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious11$0$0Apr 19, 1999--
01002E1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F07
Serious11$0$0Apr 19, 1999--
01002F1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious11$0$0Apr 19, 1999--

Showing the 7 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 29, 1998Unprogrammed Related (G) · Partial scope, Safety#302354964$3154 viol.

Inspection #302354964

Dates

Opened
Oct 29, 1998
Closing Conference Date
Oct 29, 1998
Closed
Mar 2, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$350
Penalties on Record
$315
Site Address
1709 Shipyard Blvd, Wilmington, NC 28403
Industry
236220 Commercial and Institutional Building Construction

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B10
Serious14$350$315Dec 28, 1998--
01001B1926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious14$0$0Dec 28, 1998--
01001C1926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B01
Serious14$0$0Dec 28, 1998--
01001D1926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Serious14$0$0Dec 28, 1998--
Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements6 citations · $125
1926.405Electrical - Wiring Methods (Construction)5 citations · $80
1926.20General Safety and Health Provisions5 citations · $175

Industry comparison

Violations per inspection
This employer5.3
Industry average1.5
Penalties per inspection
This employer$157
Industry average$1,286

Construction of Buildings, 202,676 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: nonresidential building construction reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 6.8%; NAICS 2362 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in WILMINGTON, NC