Skip to content
SafetyRecord logoSafetyRecord
XCEL ENERGY
$13,500
penalties
3
viol.
1
insp.

XCEL ENERGY

HWY 491 & CRAZY HORSE RD, ARTESIA, NM 88210NAICS 221122 Electric Power Distribution

Inspections
1
Jun 2013 to Jun 2013 · 1 safety, 0 health
Violations
3
across 1 inspection
Penalties on record
$13,500
latest amounts in DOL records
By classification
Serious 3Willful 0Repeat 0Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 15, 2013FatalityAccident (A) · Partial scope, Safety#317079994$13,5003 viol.

Inspection #317079994

Dates

Opened
Jun 15, 2013
Closing Conference Date
Jun 19, 2013
Contested
Jan 3, 2014
Final Order
May 7, 2014
Closed
May 7, 2014

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
35
Related Activity
1 accident

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$0
Penalties on Record
$13,500
Site Address
Hwy 491 & Crazy Horse Rd, Artesia, NM 88210
Industry
221122 Electric Power Distribution

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

FatalityJun 15, 2013

Employee is killed contacting energized overhead line

Injury: Electric ShockBody part: Body SystemSource: Electrical Apparatus/WiringEvent: Shock

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01008A1910.269
Electric Power Generation, Transmission, and Distribution
OSHA citation code: 19100269 C01
Serious12$0$4,500Dec 20, 2013Jan 3, 2014May 7, 2014
01008B1910.269
Electric Power Generation, Transmission, and Distribution
OSHA citation code: 19100269 M03 II
Serious12$0$4,500Dec 20, 2013Jan 3, 2014May 7, 2014
01008C1910.269
Electric Power Generation, Transmission, and Distribution
OSHA citation code: 19100269 N02
Serious12$0$4,500Dec 20, 2013Jan 3, 2014May 7, 2014
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.269Electric Power Generation, Transmission, and Distribution3 citations · $13,500

Industry comparison

Violations per inspection
This employer3.0
Industry average2.0
Penalties per inspection
This employer$13,500
Industry average$2,032

Utilities, 14,301 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: electric power transmission, control, and distribution reported 2.1 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.7%; NAICS 22112 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source