Skip to content
SafetyRecord logoSafetyRecord

Inspection #100935659

Closed

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

The Occupational Safety and Health Administration (OSHA) conducted a referral inspection of CARL FALKENSTEIN INC. at 2717 N. Howard Street, Philadelphia, PA 19133 on Jun 14, 1990. The inspection scope was complete. The case was closed on May 13, 1996.

OSHA documented 52 violations (44 serious, 8 other-than-serious) with total penalties on record of $10,140. This inspection is linked to 1 complaint, 1 referral in OSHA records.

OSHA collected 130 air monitoring samples covering 14 substances during this inspection, including Antimony and Compounds (as Sb), Beryllium and Beryllium Compounds (as Be), Cadmium Fume (as Cd), Chromium, Metal and Insoluble Salts, Cobalt, Metal, Dust and Fume (as Co), and 9 more.

This employer has 3 other OSHA inspections on record at this establishment.

Inspection Details

Inspection Number
100935659
Type
Referral (C)
Scope
Complete
Opened
Jun 14, 1990
Closed
May 13, 1996
Total Violations
52
Penalties on Record
$10,140
Initial Penalties
$16,900
Related Activity
1 complaint, 1 referral
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Establishment

Address
2717 N. Howard Street, Philadelphia, PA 19133
Industry
335121 Residential Electric Lighting Fixture Manufacturing

Other Inspections of This Employer3 on record

Other OSHA inspections of the same establishment. Linked via establishment ID (exact government key).

Enforcement Outcome

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page.

Status on Record
Closed

Inspection closed May 13, 1996.

Citations on Record
52

44 serious, 8 other-than-serious.

Initial Penalties
$16,900

Citation amounts as first recorded in OSHA's penalty fields.

Current Penalties
$10,140

Latest published amounts after changes in the enforcement process.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)90mg/m³
Beryllium and Beryllium Compounds (as Be)80mg/m³
Cadmium Fume (as Cd)90mg/m³
Chromium, Metal and Insoluble Salts90mg/m³
Cobalt, Metal, Dust and Fume (as Co)90mg/m³
Copper Fume (as Cu)90 - 0.0097mg/m³
Iron Oxide Fume90 - 0.0305mg/m³
Lead, Inorganic (as Pb)90mg/m³
Manganese Fume (as Mn)90mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)90mg/m³
Nickel, Metal and Insoluble compounds (as Ni)90mg/m³
Silica, Crystalline Quartz (Respirable Fraction)140 - 13%
Vanadium fume (as V2O5)90mg/m³
Zinc Oxide Fume90 - 4.4944mg/m³

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Violations

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

CitationStandardTypeInitialCurrentAbatementContestFinal Order
01001A1910.20
Access to Employee Exposure and Medical Records
OSHA citation code: 19100020 G01 III
Serious$300$180Dec 21, 1990--
01001B1910.20
Access to Employee Exposure and Medical Records
OSHA citation code: 19100020 G02
Serious$0$0Dec 21, 1990--
010021910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Serious$200$120Jan 3, 1991--
01003A1910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 K02
Serious$500$300Dec 11, 1990--
01003B1910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Serious$0$0Jan 14, 1991--
01003C1910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q02
Serious$0$0Jan 14, 1991--
010041910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Serious$700$420Jun 13, 1991--
010051910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious$700$420Mar 13, 1991--
010061910.95
Occupational Noise Exposure
OSHA citation code: 19100095 E
Serious$700$420Jan 14, 1991--
010071910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G01
Serious$700$420Jan 11, 1991--
010081910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G06
Serious$700$420Jan 13, 1991--
010091910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Serious$700$420Feb 1, 1991--
010101910.95
Occupational Noise Exposure
OSHA citation code: 19100095 L01
Serious$700$420Feb 1, 1991--
01011A1910.106
Flammable Liquids
OSHA citation code: 19100106 E06 I
Serious$400$240Jan 7, 1991--
01011B1910.106
Flammable Liquids
OSHA citation code: 19100106 E06 II
Serious$0$0Jan 7, 1991--
01012A1910.106
Flammable Liquids
OSHA citation code: 19100106 D03 II
Serious$400$240Jan 14, 1991--
01012B1910.106
Flammable Liquids
OSHA citation code: 19100106 D07 I
Serious$0$0Jan 7, 1991--
010131910.120
Hazardous Waste Operations and Emergency Response
OSHA citation code: 19100120 Q01
Serious$600$360Feb 14, 1991--
010141910.120
Hazardous Waste Operations and Emergency Response
OSHA citation code: 19100120 Q06
Serious$600$360Mar 13, 1991--
010151910.120
Hazardous Waste Operations and Emergency Response
OSHA citation code: 19100120 Q09
Serious$600$360Mar 13, 1991--
010161910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Serious$500$300Feb 1, 1991--
010171910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Serious$600$360Dec 13, 1990--
010181910.141
Sanitation
OSHA citation code: 19100141 G02
Serious$300$180Dec 10, 1990--
010191910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious$700$420Feb 15, 1991--
010201910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious$600$360Jan 13, 1991--
01021A1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Serious$500$300Jan 13, 1991--
01021B1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Serious$0$0Feb 15, 1991--
010221910.176
Handling Materials - General
OSHA citation code: 19100176 A
Serious$300$180Dec 13, 1990--
010231910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious$500$300Feb 15, 1991--
010241910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious$400$240Feb 15, 1991--
010251910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious$400$240Feb 15, 1991--
010261910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious$400$240Feb 15, 1991--
010271910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious$400$240Jan 11, 1991--
010281910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Serious$300$180Jan 11, 1991--
010291910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F06 I
Serious$200$120Jan 11, 1991--
010301910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious$200$120Jan 4, 1991--
01031A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Serious$500$300Jan 4, 1991--
01031B1910.1200
Hazard Communication
OSHA citation code: 19101200 E02 II
Serious$0$0Jan 4, 1991--
01031C1910.1200
Hazard Communication
OSHA citation code: 19101200 E02 III
Serious$0$0Jan 4, 1991--
01032A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious$500$300Feb 1, 1991--
01032B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious$0$0Feb 1, 1991--
010331910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious$500$300Jan 13, 1991--
01034A1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious$500$300Feb 22, 1991--
01034B1910.1200
Hazard Communication
OSHA citation code: 19101200 H02 II
Serious$0$0Feb 22, 1991--
020011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other$100$60Dec 11, 1990--
020021904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other$0$0Jan 4, 1991--
020031904.5
Determination of Work-Relatedness
OSHA citation code: 19040005 C
Other$0$0Jan 4, 1991--
020041910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Other$0$0Jan 16, 1991--
020051910.134
Respiratory Protection
OSHA citation code: 19100134 B02
Other$0$0Dec 11, 1990--
020061910.134
Respiratory Protection
OSHA citation code: 19100134 B11
Other$0$0Dec 11, 1990--
020071910.141
Sanitation
OSHA citation code: 19100141 D02 IV
Other$0$0Dec 13, 1990--
020081910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B02 II
Other$0$0Dec 13, 1990--

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Data Source and Methodology

Data synced daily

Data on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. On inspection pages, the status display follows the DOL inspection record first. If the DOL inspection feed includes a close date, we show the inspection as closed. If the inspection feed has no close date but all citation records tied to that inspection show a final order date, we label the page "Final Order Recorded" and disclose the citation dates instead of inferring a close date. Chemical exposure sampling data and OSHA Permissible Exposure Limits (PELs) are sourced from the OSHA Occupational Chemical Database, matched via IMIS analyte codes. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.