ZALK JOSEPHS FABRICATORS INC.
400 INDUSTRIAL CIRCLE, Stoughton, WI 53589
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jul 29, 2002#303868335Jul 29, 2002Planned (H) · Partial scope, Safety#303868335$00 viol.0 violations$0 in penalties
Inspection #303868335
Dates
- Opened
- Jul 29, 2002
- Closing Conference Date
- Jul 29, 2002
- Closed
- Jul 31, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 90
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 400 Industrial Circle, Stoughton, WI 53589
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Nov 20, 1997#300564333Nov 20, 1997Planned (H) · No Inspection scope, Safety#300564333$00 viol.0 violations$0 in penalties
Inspection #300564333
Dates
- Opened
- Nov 20, 1997
- Closing Conference Date
- Nov 20, 1997
- Closed
- Nov 20, 1997
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 95
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 400 Industrial Circle, Stoughton, WI 53589
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Mar 8, 1990#102513355Mar 8, 1990Complaint (B) · Complete scope, Health#102513355$4004 viol.4 violations$400 in penalties
Inspection #102513355
Dates
- Opened
- Mar 8, 1990
- Closing Conference Date
- Mar 13, 1990
- Closed
- Jul 19, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 125
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 2 serious, 2 other-than-serious
- Initial Penalties
- $560
- Penalties on Record
- $400
- Site Address
- 400 Industrial Dr., Stoughton, WI 53589
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 1614P / 2A | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 1412P / 2A | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 1614P / 2A | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 1614P / 2A | 0 - 0.0237 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 1614P / 2A | 0 | mg/m³ |
| Copper Fume (as Cu) | 1614P / 2A | 0 - 0.0489 | mg/m³ |
| Iron Oxide Fume | 1614P / 2A | 0 - 12.9662 | mg/m³ |
| Lead, Inorganic (as Pb) | 1614P / 2A | 0 | mg/m³ |
| Manganese Fume (as Mn) | 1614P / 2A | 0 - 0.9412 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 1614P / 2A | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 1614P / 2A | 0 - 0.0139 | mg/m³ |
| Vanadium fume (as V2O5) | 1614P / 2A | 0 | mg/m³ |
| Zinc Oxide Fume | 1614P / 2A | 0 - 0.0163 | mg/m³ |
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.94 Ventilation OSHA citation code: 19100094 A07 | Serious | 1 | 4 | $560 | $400 | Apr 19, 1990 | - | - |
| 01001B | 1910.94 Ventilation OSHA citation code: 19100094 A03 IA | Serious | 1 | 24 | $0 | $0 | Apr 19, 1990 | - | - |
| 02001 | 1910.20 Access to Employee Exposure and Medical Records OSHA citation code: 19100020 G01 I | Other | 1 | 125 | $0 | $0 | Mar 23, 1990 | - | - |
| 02002 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 C | Other | 4 | 44 | $0 | $0 | May 21, 1990 | - | - |
Mar 8, 1990#102513330Mar 8, 1990Complaint (B) · Partial scope, Safety#102513330$98011 viol.11 violations$980 in penalties
Inspection #102513330
Dates
- Opened
- Mar 8, 1990
- Closing Conference Date
- Mar 12, 1990
- Closed
- Jul 19, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 125
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 8 serious, 3 other-than-serious
- Initial Penalties
- $1,200
- Penalties on Record
- $980
- Site Address
- 400 Industrial Drive, Stoughton, WI 53589
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (10 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C01 | Serious | 1 | 2 | $240 | $240 | Mar 23, 1990 | - | - |
| 01001B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C02 | Serious | 2 | 2 | $0 | $0 | Apr 19, 1990 | - | - |
| 01001C | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 J02 | Serious | 1 | 1 | $0 | $0 | Mar 21, 1990 | - | - |
| 01003A | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G01 | Serious | 1 | 84 | $240 | $240 | May 1, 1990 | - | - |
| 01003B | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G02 | Serious | 1 | 84 | $0 | $0 | May 1, 1990 | - | - |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 2 | 2 | $300 | $300 | May 1, 1990 | - | - |
| 01005A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 II | Serious | 1 | 2 | $420 | $200 | Mar 21, 1990 | - | - |
| 01005B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Serious | 1 | 2 | $0 | $0 | Mar 21, 1990 | - | - |
| 02001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A01 | Other | 1 | 3 | $0 | $0 | Mar 27, 1990 | - | - |
| 02002 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 B01 | Other | 1 | 3 | $0 | $0 | Mar 23, 1990 | - | - |
Showing the 10 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Nov 29, 1983#15463052Nov 29, 1983Follow-Up (F) · Partial scope, Safety#15463052$00 viol.0 violations$0 in penalties
Inspection #15463052
Dates
- Opened
- Nov 29, 1983
- Closing Conference Date
- Nov 29, 1983
- Closed
- Nov 29, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 86
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 400 Industrial Circle, Stoughton, WI 53589
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
5 inspections, 1983 to 2002. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.