Skip to content
SafetyRecord logoSafetyRecord
ALTO MANUFACTURING COMPANY
$5,051
penalties
24
viol.
7
insp.

ALTO MANUFACTURING COMPANY

2850 NORTH ASHLAND, CHICAGO, IL 60657

Inspections
7
Oct 1986 to Jul 1998 · 7 safety, 0 health
Violations
24
across 7 inspections
Penalties on record
$5,051
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 4Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 21, 1998Complaint (B) · Partial scope, Safety#302041678$1,9517 viol.

Inspection #302041678

Dates

Opened
Jul 21, 1998
Closing Conference Date
Jul 21, 1998
Closed
Sep 29, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
38
Related Activity
1 complaint

Violations and Penalties

Total Violations
7
Violation Types
4 serious, 3 other-than-serious
Initial Penalties
$3,000
Penalties on Record
$1,951
Site Address
2850 North Ashland, Chicago, IL 60657
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious124$1,000$650Oct 7, 1998--
01002A1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious1-$1,250$813Oct 7, 1998--
01002B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 ID
Serious23$0$0Oct 7, 1998--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious12$750$488Sep 9, 1998--
020011910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Other14$0$0Sep 9, 1998--
020021910.217
Mechanical Power Presses
OSHA citation code: 19100217 G
Other1-$0$0Sep 9, 1998--
020031910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Other14$0$0Sep 9, 1998--
Jun 22, 1988Monitoring (D) · Partial scope, Safety#103263075$00 viol.

Inspection #103263075

Dates

Opened
Jun 22, 1988
Closing Conference Date
Jun 22, 1988
Closed
Jun 23, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
35

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2850 North Ashland, Chicago, IL 60657
Industry
Not classified in OSHA's inspection record.

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Oct 27, 1987Complaint (B) · Partial scope, Safety#103260741$1,50011 viol.

Inspection #103260741

Dates

Opened
Oct 27, 1987
Closing Conference Date
Dec 7, 1987
Closed
Feb 24, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
35
Related Activity
1 complaint

Violations and Penalties

Total Violations
11
Violation Types
5 serious, 2 repeat, 4 other-than-serious
Initial Penalties
$2,480
Penalties on Record
$1,500
Site Address
2850 North Ashland, Chicago, IL 60657
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (7 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.94
Ventilation
OSHA citation code: 19100094 D12 III
Serious11$160$90Feb 24, 1988--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious1010$400$210Feb 24, 1988--
01003A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious22$240$150Feb 24, 1988--
01003B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious22$0$0Feb 24, 1988--
010041910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious22$240$150Feb 24, 1988--
020011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Repeat11$1,280$750Jun 15, 1988--
020021910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 ID
Repeat11$160$150Feb 24, 1988--

Showing the 7 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jul 30, 1987Follow-Up (F) · Partial scope, Safety#101172351$00 viol.

Inspection #101172351

Dates

Opened
Jul 30, 1987
Closing Conference Date
Jul 30, 1987
Closed
Aug 11, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
55

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2850 North Ashland, Chicago, IL 60657
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

May 13, 1987Monitoring (D) · Partial scope, Safety#101335149$00 viol.

Inspection #101335149

Dates

Opened
May 13, 1987
Closing Conference Date
May 13, 1987
Closed
May 14, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
55

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2850 N. Ashland, Chicago, IL 60657
Industry
Not classified in OSHA's inspection record.

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Feb 5, 1987Follow-Up (F) · Partial scope, Safety#103257606$1,6003 viol.

Inspection #103257606

Dates

Opened
Feb 5, 1987
Closing Conference Date
Feb 5, 1987
Closed
Aug 11, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
51

Violations and Penalties

Total Violations
3
Violation Types
2 repeat, 1 other-than-serious
Initial Penalties
$1,600
Penalties on Record
$1,600
Site Address
2850 North Ashland, Chicago, IL 60657
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Repeat11$800$800Jun 1, 1987--
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Repeat11$800$800Jun 1, 1987--
020011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 ID
Other66$0$0May 16, 1987--
Oct 2, 1986Follow-Up (F) · Partial scope, Safety#100120575$03 viol.

Inspection #100120575

Dates

Opened
Oct 2, 1986
Closing Conference Date
Oct 2, 1986
Closed
Aug 11, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
51

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2850 N. Ashland, Chicago, IL 60657
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other125$0$0Jun 16, 1987--
010021910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Other127$0$0May 16, 1987--
010031910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other125$0$0Jun 16, 1987--

Failure to Abate Penalties3 citations, $3,000 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 3 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01001#103257606Feb 18, 1987$1,000--
01002#103257606Feb 18, 1987$1,000--
01003#103257606Feb 18, 1987$1,000--
Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses10 citations · $2,513
1910.212General Requirements for All Machines (Machine Guarding)4 citations · $1,660
1910.219Mechanical Power-Transmission Apparatus3 citations · $638

Other inspected employers in CHICAGO, IL