Skip to content
SafetyRecord logoSafetyRecord
HOUMA ARMATURE WORKS & SUPPLY
$1,575
penalties
15
viol.
2
insp.

HOUMA ARMATURE WORKS & SUPPLY

2534 CUMMINS RD., HOUMA, LA 70363

Inspections
2
Oct 1984 to Feb 1996 · 1 safety, 1 health
Violations
15
across 2 inspections
Penalties on record
$1,575
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 10

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 14, 1996Planned (H) · Complete scope, Safety#103431490$1,57514 viol.

Inspection #103431490

Dates

Opened
Feb 14, 1996
Closing Conference Date
Feb 14, 1996
Closed
Apr 18, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
33

Violations and Penalties

Total Violations
14
Violation Types
5 serious, 9 other-than-serious
Initial Penalties
$3,150
Penalties on Record
$1,575
Site Address
2534 Cummins Rd., Houma, LA 70363
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (14 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious13$525$275Mar 7, 1996--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C06
Serious11$700$350Mar 21, 1996--
010031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious25$525$200Mar 14, 1996--
010041910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious15$525$275Mar 7, 1996--
010051910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious25$875$475Mar 7, 1996--
020011910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IIB1
Other11$0$0Mar 7, 1996--
020021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Other11$0$0Mar 28, 1996--
020031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 IV
Other11$0$0Mar 28, 1996--
020041910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C03
Other11$0$0Mar 7, 1996--
020051910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 G01 V
Other310$0$0Mar 7, 1996--
020061910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J03
Other310$0$0Mar 28, 1996--
020071910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other11$0$0Mar 7, 1996--
020081910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 I
Other13$0$0Mar 7, 1996--
020091910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other110$0$0Mar 21, 1996--
Oct 12, 1984Planned (H) · Complete scope, Health#1381961$01 viol.

Inspection #1381961

Dates

Opened
Oct 12, 1984
Closing Conference Date
Oct 12, 1984
Closed
May 17, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
26

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2531 Cummins Rd, Houma, LA 70363
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other126$0$0Nov 12, 1984--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.107Spray Finishing Using Flammable and Combustible Materials4 citations · $350
1910.179Overhead and Gantry Cranes2 citations · $0
1910.304Electrical - Wiring Design and Protection2 citations · $750

Other inspected employers in HOUMA, LA