Skip to content
SafetyRecord logoSafetyRecord
CASCADE ENTERPRISES INC
$1,110
penalties
23
viol.
5
insp.

CASCADE ENTERPRISES INC

1559 DOWELL RD, GRANTS PASS, OR 97527

Inspections
5
Apr 1991 to Mar 2007 · 5 safety, 0 health
Violations
23
across 5 inspections
Penalties on record
$1,110
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 14

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 16, 2007Follow-Up (F) · Partial scope, Safety#310866900$00 viol.

Inspection #310866900

Dates

Opened
Mar 16, 2007
Closing Conference Date
Mar 16, 2007
Closed
Mar 16, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
14

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1559 Dowell Rd, Grants Pass, OR 97527
Industry
327331 Concrete Block and Brick Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 24, 2007Planned (H) · Complete scope, Safety#309697282$03 viol.

Inspection #309697282

Dates

Opened
Jan 24, 2007
Closing Conference Date
Jan 24, 2007
Closed
May 18, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
14

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1559 Dowell Rd, Grants Pass, OR 97527
Industry
327331 Concrete Block and Brick Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 E01
Other16$0$0Mar 3, 2007--
010021910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A03 II
Other114$0$0Jan 24, 2007--
01003702022323
OSHA citation code: 702022323 A
Other114$0$0Mar 3, 2007--
Mar 31, 1993Planned (H) · Partial scope, Safety#123737553$00 viol.

Inspection #123737553

Dates

Opened
Mar 31, 1993
Closing Conference Date
Mar 31, 1993
Closed
Mar 31, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1559 Dowell Rd, Grants Pass, OR 97527
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jan 4, 1993Planned (H) · Complete scope, Safety#123735169$48010 viol.

Inspection #123735169

Dates

Opened
Jan 4, 1993
Closing Conference Date
Jan 4, 1993
Closed
Jul 29, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
10
Violation Types
5 serious, 5 other-than-serious
Initial Penalties
$480
Penalties on Record
$480
Site Address
1559 Dowell Rd, Grants Pass, OR 97527
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IH
Serious13$300$300Feb 3, 1993--
01001B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious13$0$0Feb 3, 1993--
01001C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IH
Serious13$0$0Feb 3, 1993--
01001D1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IH
Serious13$0$0Feb 3, 1993--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious13$180$180Feb 3, 1993--
02003A7127002001Other112$0$0Mar 3, 1993--
02003B7127002002Other112$0$0Mar 3, 1993--
020041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Other13$0$0Jan 30, 1993--
02005756009501Other13$0$0Jan 30, 1993--
02006761007004Other13$0$0Jan 30, 1993--
Apr 23, 1991Planned (H) · Complete scope, Safety#108260043$63010 viol.

Inspection #108260043

Dates

Opened
Apr 23, 1991
Closing Conference Date
Apr 23, 1991
Closed
Jun 26, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10

Violations and Penalties

Total Violations
10
Violation Types
4 serious, 6 other-than-serious
Initial Penalties
$630
Penalties on Record
$630
Site Address
1559 Dowell Rd, Grants Pass, OR 97527
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious13$350$350Jun 11, 1991--
01002A1910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 F
Serious14$105$105Jun 11, 1991--
01002B1910.23
Ladders
OSHA citation code: 19100023 D01 IV
Serious14$0$0Jun 11, 1991--
01003762.563Serious11$75$75Apr 23, 1991--
020047155001501Other119$0$0Jun 11, 1991--
020051910.303
Electrical - General Requirements
OSHA citation code: 19100303 C
Other22$0$0May 21, 1991--
020061910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Other11$0$0May 21, 1991--
020071910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Other11$0$0May 17, 1991--
02008756.165Other24$0$0May 17, 1991--
02009740004501Other11$100$100May 21, 1991--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment5 citations · $300
1910.304Electrical - Wiring Design and Protection2 citations · $0
1910.23Ladders2 citations · $0

Industry comparison

BLS 2024 survey: concrete pipe, brick, and block manufacturing reported 2.3 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 21.9%; NAICS 32733 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in GRANTS PASS, OR