Skip to content
SafetyRecord logoSafetyRecord
FOUNTAIN COUNTY
$0
penalties
15
viol.
9
insp.

FOUNTAIN COUNTY

216 UNION ST, COVINGTON, IN 47932NAICS 921110

Inspections
9
Feb 1985 to Aug 1990 · 9 safety, 0 health
Violations
15
across 9 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 0Other 7

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 1, 1990Follow-Up (F) · Partial scope, Safety#108561002$00 viol.

Inspection #108561002

Dates

Opened
Aug 1, 1990
Closing Conference Date
Aug 1, 1990
Closed
Aug 9, 1990

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
120

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
(courthouse) U S 136 West And 3rd Street, Covington, IN 47932
Industry
921110

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 1, 1990Planned (H) · Complete scope, Safety#107965725$02 viol.

Inspection #107965725

Dates

Opened
Feb 1, 1990
Closing Conference Date
Feb 1, 1990
Closed
Mar 15, 1990

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
(sheriff Dept & County Jail) 216 Union Street, Covington, IN 47932
Industry
921110

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious111$0$0Mar 6, 1990--
020011910.141
Sanitation
OSHA citation code: 19100141 G04
Other111$0$0Mar 6, 1990--
Feb 1, 1990Planned (H) · Complete scope, Safety#107965717$08 viol.

Inspection #107965717

Dates

Opened
Feb 1, 1990
Closing Conference Date
Feb 1, 1990
Closed
Oct 30, 1990

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
52

Violations and Penalties

Total Violations
8
Violation Types
2 serious, 6 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
(courthouse) U S 136 West And 3rd Street, Covington, IN 47932
Industry
921110

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.120
Hazardous Waste Operations and Emergency Response
OSHA citation code: 19100120 B01 I
Serious142$0$0Mar 27, 1990--
01001B1910.120
Hazardous Waste Operations and Emergency Response
OSHA citation code: 19100120 L03
Serious142$0$0Mar 27, 1990--
02001400.402Other195$0$0Mar 13, 1990--
02002400.405Other195$0$0Mar 13, 1990--
020031910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other142$0$0Mar 27, 1990--

Showing the 5 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Failure to Abate Penalties6 citations

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 6 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01001A#108561002Aug 10, 1990---
01001B#108561002Aug 10, 1990---
02003#108561002Aug 10, 1990---

Showing the 3 FTA rows present in the first 5 citations on this inspection. OSHA's record shows 6 total citations with FTA activity for this inspection. The complete list is available at enforcedata.dol.gov.

Jul 14, 1988Planned (H) · Complete scope, Safety#103974218$02 viol.

Inspection #103974218

Dates

Opened
Jul 14, 1988
Closing Conference Date
Jul 14, 1988
Closed
Sep 26, 1988

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
(jail & Sheriff Dept) 216 Union Street, Covington, IN 47932
Industry
921110

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious112$0$0Aug 5, 1988--
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious124$0$0Aug 5, 1988--
Jul 14, 1988Planned (H) · Complete scope, Safety#103974200$00 viol.

Inspection #103974200

Dates

Opened
Jul 14, 1988
Closing Conference Date
Jul 14, 1988
Closed
Jul 25, 1988

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
52

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
(courthouse) U S 136 West And 3rd Street, Covington, IN 47932
Industry
921110

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jun 9, 1986Planned (H) · Complete scope, Safety#101970606$02 viol.

Inspection #101970606

Dates

Opened
Jun 9, 1986
Closing Conference Date
Jun 9, 1986
Closed
Sep 17, 1986

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
216 Union St (sheriff's Dept/Jail), Covington, IN 47932
Industry
921110

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.303
Electrical - General Requirements
OSHA citation code: 19100303 G 1 II
Serious112$0$0Jun 16, 1986--
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F 5 V
Serious112$0$0Jun 18, 1986--
Jun 9, 1986Planned (H) · Complete scope, Safety#101970531$00 viol.

Inspection #101970531

Dates

Opened
Jun 9, 1986
Closing Conference Date
Jun 9, 1986
Closed
Jun 9, 1986

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
52

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Us 136 W & 3rd St (courthouse), Covington, IN 47932
Industry
921110

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Feb 28, 1985Planned (H) · Complete scope, Safety#2733301$01 viol.

Inspection #2733301

Dates

Opened
Feb 28, 1985
Closing Conference Date
Feb 28, 1985
Closed
Jun 19, 1985

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
216 Union St, Covington, IN 47932
Industry
921110

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious12$0$0Mar 11, 1985--
Feb 28, 1985Planned (H) · Complete scope, Safety#2733293$00 viol.

Inspection #2733293

Dates

Opened
Feb 28, 1985
Closing Conference Date
Feb 28, 1985
Closed
Mar 7, 1985

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
43

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Us 136 W Courthouse, Covington, IN 47932
Industry
921110

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 9 of 9, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication4 citations · $0
1910.304Electrical - Wiring Design and Protection4 citations · $0
1910.120Hazardous Waste Operations and Emergency Response2 citations · $0

Industry comparison

Violations per inspection
This employer1.7
Industry average2.0
Penalties per inspection
This employer$0
Industry average$727

Public Administration, 12,083 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in COVINGTON, IN

All employers in COVINGTON →