BANNER METALS, INC.
WEST MAIN STREET, BUS. RD 209, STROUDSBURG, PA 18360
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jan 7, 1997#109363184Jan 7, 1997Planned (H) · Complete scope, Health#109363184$1,37511 viol.11 violations$1,375 in penalties
Inspection #109363184
Dates
- Opened
- Jan 7, 1997
- Closing Conference Date
- Jan 8, 1997
- Closed
- Apr 7, 1997
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 107
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 6 serious, 5 other-than-serious
- Initial Penalties
- $2,750
- Penalties on Record
- $1,375
- Site Address
- West Main Street, Stroudsburg, PA 18360
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (10 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 3 | 2 | $1,100 | $550 | Mar 19, 1997 | - | - |
| 01002A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 2 | 1 | $825 | $415 | Mar 19, 1997 | - | - |
| 01002B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E02 I | Serious | 1 | 2 | $0 | $0 | Mar 19, 1997 | - | - |
| 01002C | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Serious | 1 | 1 | $0 | $0 | Mar 19, 1997 | - | - |
| 01003A | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Serious | 1 | 1 | $825 | $410 | Mar 19, 1997 | - | - |
| 01003B | 1910.1200 Hazard Communication OSHA citation code: 19101200 H | Serious | 2 | 1 | $0 | $0 | Apr 19, 1997 | - | - |
| 02001 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 I | Other | 1 | 1 | $0 | $0 | Mar 19, 1997 | - | - |
| 02002 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 I | Other | 1 | 1 | $0 | $0 | Mar 19, 1997 | - | - |
| 02003 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 II | Other | 1 | 1 | $0 | $0 | Mar 5, 1997 | - | - |
| 02004 | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 C01 I | Other | 1 | 1 | $0 | $0 | Mar 19, 1997 | - | - |
Showing the 10 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Mar 23, 1994#17621608Mar 23, 1994Planned (H) · Complete scope, Safety#17621608$1,6253 viol.3 violations$1,625 in penalties
Inspection #17621608
Dates
- Opened
- Mar 23, 1994
- Closing Conference Date
- Apr 7, 1994
- Closed
- Jun 12, 1994
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 60
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 2 serious, 1 other-than-serious
- Initial Penalties
- $2,500
- Penalties on Record
- $1,625
- Site Address
- West Main Street, Stroudsburg, PA 18360
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.156 Fire Brigades OSHA citation code: 19100156 B02 | Serious | 1 | 12 | $1,750 | $875 | Apr 15, 1994 | - | - |
| 01002 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 D06 I | Serious | 1 | 2 | $750 | $750 | Jun 1, 1994 | - | - |
| 02001 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 E01 IV | Other | 1 | 2 | $0 | $0 | Apr 15, 1994 | - | - |
Jul 27, 1988#626580Jul 27, 1988Referral (C) · Partial scope, Safety#626580$4004 viol.4 violations$400 in penalties
Inspection #626580
Dates
- Opened
- Jul 27, 1988
- Closing Conference Date
- Aug 2, 1988
- Closed
- Sep 28, 1988
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 220
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 serious
- Initial Penalties
- $400
- Penalties on Record
- $400
- Site Address
- West Main Street, Stroudsburg, PA 18360
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 I | Serious | 1 | 1 | $400 | $400 | Aug 20, 1988 | - | - |
| 01001B | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 I | Serious | 1 | 1 | $0 | $0 | Aug 20, 1988 | - | - |
| 01001C | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 II | Serious | 1 | 1 | $0 | $0 | Aug 20, 1988 | - | - |
| 01001D | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 II | Serious | 1 | 1 | $0 | $0 | Aug 20, 1988 | - | - |
Jun 30, 1987#815696Jun 30, 1987Complaint (B) · Partial scope, Health#815696$2,25013 viol.13 violations$2,250 in penalties
Inspection #815696
Dates
- Opened
- Jun 30, 1987
- Closing Conference Date
- Sep 21, 1987
- Closed
- Jan 22, 1988
Inspection
- Advance Notice
- Yes
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 175
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 13
- Violation Types
- 9 serious, 4 other-than-serious
- Initial Penalties
- $2,970
- Penalties on Record
- $2,250
- Site Address
- West Main Street, Stroudsburg, PA 18360
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling26 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| 2-Butanone | 40 | 0 - 17.3 | |
| 2-Butoxyethanol | 10 | 0 - 3.7 | ppm |
| Antimony and Compounds (as Sb) | 31P / 2A | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 21P / 1A | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 31P / 2A | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 31P / 2A | 0 - 0.0059 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 31P / 2A | 0 | mg/m³ |
| Copper Dusts and Mists (as Cu) | 3 | 0.038 - 0.4 | mg/m³ |
| Copper Fume (as Cu) | 75P / 2A | 0 - 0.21 | mg/m³ |
| Ethanolamine | 4 | 0 | ppm |
| Hexone | 18 | 0.1 - 4.6 | ppm |
| Iron Oxide Fume | 31P / 2A | 0 - 0.0266 | mg/m³ |
| Lead, Inorganic (as Pb) | 108P / 2A | 0 - 0.039 | mg/m³ |
| Manganese Fume (as Mn) | 31P / 2A | 0 - 0.007 | mg/m³ |
| Methyl (n-amyl) ketone | 10 | 0 - 5.5 | ppm |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 31P / 2A | 0 | mg/m³ |
| n-Butyl Acetate | 10 | 1.3 - 8 | ppm |
| Nickel, Metal and Insoluble compounds (as Ni) | 31P / 2A | 0 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 119P / 2A | 0 | mg/m³ |
| Tin, inorganic compounds (except oxides) (as Sn) | 7 | 0 - 0.018 | mg/m³ |
| Toluene | 18 | 0.04 - 7.8 | ppm |
| Toluene-2,4-Diisocyanate (TDI) | 2 | 0 | mg/m³ |
| Toluene-2,6-Diisocyanate | 2 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 31P / 2A | 0 | mg/m³ |
| Xylene | 18 | 0.05 - 1.6 | ppm |
| Zinc Oxide Fume | 31P / 2A | 0 | mg/m³ |
Violations
Violation list (10 of 13 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 C03 | Serious | 1 | 8 | $270 | $135 | Jan 7, 1988 | - | - |
| 01002A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C07 | Serious | 1 | 8 | $360 | $180 | Dec 7, 1987 | - | - |
| 01002B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B03 | Serious | 1 | 8 | $0 | $0 | Dec 7, 1987 | - | - |
| 01003 | 1910.108 Dip Tanks (Reserved) OSHA citation code: 19100108 C05 | Serious | 1 | 8 | $360 | $180 | Dec 7, 1987 | - | - |
| 01004 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Serious | 1 | 50 | $540 | $540 | Dec 15, 1987 | - | - |
| 01005A | 1910.1200 Hazard Communication OSHA citation code: 19101200 F04 I | Serious | 1 | 8 | $450 | $450 | Dec 15, 1987 | - | - |
| 01005B | 1910.1200 Hazard Communication OSHA citation code: 19101200 F04 II | Serious | 1 | 8 | $0 | $0 | Dec 15, 1987 | - | - |
| 01006 | 1910.1200 Hazard Communication OSHA citation code: 19101200 G01 | Serious | 1 | 8 | $450 | $225 | Nov 7, 1987 | - | - |
| 01007 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H | Serious | 1 | 50 | $540 | $540 | Dec 15, 1987 | - | - |
| 02001A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 D03 | Other | 1 | 2 | $0 | $0 | Oct 11, 1987 | - | - |
Showing the 10 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 3, 1985#1133222Jan 3, 1985Planned (H) · Complete scope, Safety#1133222$3504 viol.4 violations$350 in penalties
Inspection #1133222
Dates
- Opened
- Jan 3, 1985
- Closing Conference Date
- Jan 9, 1985
- Closed
- Jun 12, 1985
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 220
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 1 serious, 3 other-than-serious
- Initial Penalties
- $350
- Penalties on Record
- $350
- Site Address
- West Main Street, Bus. Rd 209, Stroudsburg, PA 18360
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 8 | 10 | $350 | $350 | Jun 3, 1985 | - | - |
| 02001 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Other | 1 | 4 | $0 | $0 | Feb 6, 1985 | - | - |
| 02002 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Other | 1 | 6 | $0 | $0 | Feb 6, 1985 | - | - |
| 02003 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Other | 1 | 6 | $0 | $0 | Feb 6, 1985 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
5 inspections, 1985 to 1997. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.