Skip to content
SafetyRecord logoSafetyRecord
ELLIOTT METAL WORKS
$7,230
penalties
91
viol.
15
insp.

ELLIOTT METAL WORKS

210 OLD PIEDMONT HWY., GREENVILLE, SC 29605

Inspections
15
Nov 1982 to Aug 2003 · 8 safety, 7 health
Violations
91
across 15 inspections
Penalties on record
$7,230
latest amounts in DOL records
By classification
Serious 53Willful 0Repeat 1Other 37

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 13, 2003Planned (H) · Complete scope, Safety#306830563$7206 viol.

Inspection #306830563

Dates

Opened
Aug 13, 2003
Closing Conference Date
Aug 13, 2003
Closed
Oct 16, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
32

Violations and Penalties

Total Violations
6
Violation Types
4 serious, 2 other-than-serious
Initial Penalties
$1,800
Penalties on Record
$720
Site Address
210 Old Piedmont Hwy., Greenville, SC 29605
Industry
333292

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E09
Serious11$450$180Aug 28, 2003--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious11$450$180Aug 28, 2003--
010031910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 VC5
Serious11$450$180Aug 28, 2003--
010041910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A03 II
Serious11$450$180Aug 28, 2003--
020011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Other11$0$0Oct 13, 2003--

Showing the 5 violations listed first by citation identifier. This inspection has 6 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Mar 6, 2002Planned (H) · Complete scope, Safety#303566111$3501 viol.

Inspection #303566111

Dates

Opened
Mar 6, 2002
Closing Conference Date
Mar 6, 2002
Closed
Jun 18, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
31

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$875
Penalties on Record
$350
Site Address
210 Old Piedmont Hwy., Greenville, SC 29605
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
0100110012
OSHA citation code: 10012 A
Serious24$875$350Apr 8, 2002--
Feb 7, 2001Planned (H) · Complete scope, Safety#302436720$9003 viol.

Inspection #302436720

Dates

Opened
Feb 7, 2001
Closing Conference Date
Feb 7, 2001
Contested
Apr 6, 2001
Final Order
Jun 6, 2001
Closed
Jul 6, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$900
Penalties on Record
$900
Site Address
210 Old Piedmont Hwy., Greenville, SC 29605
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
030011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious12$450$450Mar 2, 2001Apr 6, 2001Jun 6, 2001
030021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious11$450$450Mar 2, 2001Apr 6, 2001Jun 6, 2001
040011910.141
Sanitation
OSHA citation code: 19100141 D02 II
Other14$0$0Apr 2, 2001Apr 6, 2001Jun 6, 2001
Mar 24, 1999Planned (H) · Complete scope, Safety#302419387$6105 viol.

Inspection #302419387

Dates

Opened
Mar 24, 1999
Closing Conference Date
Mar 25, 1999
Closed
Jul 2, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
32

Violations and Penalties

Total Violations
5
Violation Types
3 serious, 2 other-than-serious
Initial Penalties
$1,525
Penalties on Record
$610
Site Address
210 Old Piedmont Hwy., Greenville, SC 29605
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C06 IV
Serious11$700$280May 7, 1999--
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 I
Serious11$525$210May 7, 1999--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C04 I
Serious11$300$120Apr 28, 1999--
020011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 II
Other13$0$0May 4, 1999--
020021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other11$0$0May 7, 1999--
Aug 7, 1997Planned (H) · Complete scope, Safety#301752051$2,2504 viol.

Inspection #301752051

Dates

Opened
Aug 7, 1997
Closing Conference Date
Aug 7, 1997
Closed
Oct 13, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
35

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$2,250
Penalties on Record
$2,250
Site Address
210 Old Piedmont Hwy., Greenville, SC 29605
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious11$450$450Sep 15, 1997--
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious11$675$675Sep 29, 1997--
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious11$675$675Sep 29, 1997--
010041910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious11$450$450Sep 15, 1997--
Apr 5, 1995Planned (H) · Complete scope, Safety#126471309$6305 viol.

Inspection #126471309

Dates

Opened
Apr 5, 1995
Closing Conference Date
Apr 5, 1995
Closed
Jun 1, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
38

Violations and Penalties

Total Violations
5
Violation Types
3 serious, 2 other-than-serious
Initial Penalties
$1,575
Penalties on Record
$630
Site Address
210 Old Piedmont Hwy., Greenville, SC 29605
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
030011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$525$210May 31, 1995--
030021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A02
Serious11$525$210Apr 25, 1995--
030031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious11$525$210May 9, 1995--
040011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Other11$0$0May 1, 1995--
040021910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Other11$0$0May 24, 1995--
Sep 13, 1994Planned (H) · Complete scope, Safety#124667692$1,05014 viol.

Inspection #124667692

Dates

Opened
Sep 13, 1994
Closing Conference Date
Sep 13, 1994
Closed
Nov 28, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
39

Violations and Penalties

Total Violations
14
Violation Types
5 serious, 9 other-than-serious
Initial Penalties
$2,625
Penalties on Record
$1,050
Site Address
210 Old Piedmont Hwy., Greenville, SC 29605
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious12$525$210Oct 14, 1994--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious12$525$210Oct 14, 1994--
010031910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious48$525$210Oct 20, 1994--
010041910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 VC5
Serious412$525$210Oct 20, 1994--
010051910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A03 II
Serious25$525$210Oct 20, 1994--

Showing the 5 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Apr 11, 1991Follow-Up (F) · Partial scope, Health#115657306$00 viol.

Inspection #115657306

Dates

Opened
Apr 11, 1991
Closing Conference Date
May 31, 1991
Closed
Aug 14, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
59

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
210 Old Piedmont Hwy., Greenville, SC 29605
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Oct 16, 1990Referral (C) · Partial scope, Health#111022737$01 viol.

Inspection #111022737

Dates

Opened
Oct 16, 1990
Closing Conference Date
Nov 26, 1990
Contested
Jan 11, 1991
Final Order
Feb 20, 1991
Closed
Aug 14, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
41
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 repeat
Initial Penalties
$1,120
Penalties on Record
$0
Site Address
210 Old Piedmont Hwy., Greenville, SC 29605
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1025
Lead
OSHA citation code: 19101025 I03 I
Repeat11$1,120$0Mar 25, 1991Jan 11, 1991Feb 20, 1991
Apr 5, 1990Follow-Up (F) · No Inspection scope, Health#107845869$00 viol.

Inspection #107845869

Dates

Opened
Apr 5, 1990
Closing Conference Date
Apr 5, 1990
Closed
Jul 23, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
210 Old Piedmont Hwy., Greenville, SC 29605
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Inspections 1 to 10 of 15, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead33 citations · $420
1910.212General Requirements for All Machines (Machine Guarding)6 citations · $1,950
1910.304Electrical - Wiring Design and Protection6 citations · $1,050

Other inspected employers in GREENVILLE, SC

All employers in GREENVILLE →