Skip to content
SafetyRecord logoSafetyRecord
BEST SIGNS & SERVICE CO., INC.
$4,575
penalties
37
viol.
2
insp.

BEST SIGNS & SERVICE CO., INC.

546 DYNAMIC DRIVE, GARNER, NC 27529

Inspections
2
Jan 1996 to Sep 2002 · 0 safety, 2 health
Violations
37
across 2 inspections
Penalties on record
$4,575
latest amounts in DOL records
By classification
Serious 19Willful 0Repeat 2Other 16

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 18, 2002Planned (H) · Complete scope, Health#305043002$35015 viol.

Inspection #305043002

Dates

Opened
Sep 18, 2002
Closing Conference Date
Sep 18, 2002
Closed
Apr 8, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
15
Violation Types
6 serious, 2 repeat, 7 other-than-serious
Initial Penalties
$600
Penalties on Record
$350
Site Address
546 Dynamic Drive, Garner, NC 27529
Industry
339950 Sign Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (15 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Repeat19$100$100Nov 19, 2002--
01001B1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 F01
Repeat11$0$0Nov 19, 2002--
02001A1910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious11$500$250Nov 19, 2002--
02001B1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious11$0$0Nov 19, 2002--
02001C1910.134
Respiratory Protection
OSHA citation code: 19100134 F01
Serious11$0$0Nov 19, 2002--
02001D1910.134
Respiratory Protection
OSHA citation code: 19100134 H01
Serious11$0$0Nov 19, 2002--
02001E1910.134
Respiratory Protection
OSHA citation code: 19100134 H02 I
Serious11$0$0Nov 19, 2002--
02001F1910.134
Respiratory Protection
OSHA citation code: 19100134 K01
Serious11$0$0Nov 19, 2002--
030011910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Other13$0$0Nov 19, 2002--
030021910.145
Specifications for Accident Prevention Signs and Tags
OSHA citation code: 19100145 F03
Other43$0$0Nov 19, 2002--
030031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other14$0$0Nov 19, 2002--
030041910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B01 I
Other12$0$0Nov 19, 2002--
03005A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other19$0$0Nov 19, 2002--
03005B1910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Other19$0$0Nov 19, 2002--
03005C1910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Other19$0$0Nov 19, 2002--
Jan 4, 1996Planned (H) · Complete scope, Health#111154381$4,22522 viol.

Inspection #111154381

Dates

Opened
Jan 4, 1996
Closing Conference Date
Feb 13, 1996
Closed
Aug 15, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
22
Violation Types
13 serious, 9 other-than-serious
Initial Penalties
$5,250
Penalties on Record
$4,225
Site Address
546 Dynamic Drive, Garner, NC 27529
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (22 of 22 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious16$750$650Feb 26, 1996--
01002A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Serious16$450$375Mar 25, 1996--
01002B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 IV
Serious16$0$0Mar 25, 1996--
01002C1910.106
Flammable Liquids
OSHA citation code: 19100106 D03 II
Serious16$0$0Mar 25, 1996--
01002D1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 D11
Serious16$0$0Mar 25, 1996--
01002E1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious26$0$0Feb 26, 1996--
010031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E09
Serious11$750$650Mar 11, 1996--
01004A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious12$750$650Mar 11, 1996--
01004B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious12$0$0Mar 11, 1996--
01005A1910.1025
Lead
OSHA citation code: 19101025 D02
Serious11$1,050$900Mar 25, 1996--
01005B1910.1025
Lead
OSHA citation code: 19101025 L01 I
Serious11$0$0Mar 25, 1996--
01005C1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious11$0$0Mar 25, 1996--
01005D1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious11$0$0Mar 25, 1996--
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other115$1,500$1,000Mar 11, 1996--
02002A1910.38
Emergency Action Plans
OSHA citation code: 19100038 A01
Other115$0$0Mar 25, 1996--
02002B1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Other16$0$0Mar 11, 1996--
02002C1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Other16$0$0Mar 11, 1996--
02002D1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Other16$0$0Mar 11, 1996--
020031910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Other16$0$0Mar 11, 1996--
020041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other12$0$0Mar 11, 1996--
020051910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other16$0$0Feb 26, 1996--
020061910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Other11$0$0Mar 25, 1996--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication6 citations · $0
1910.134Respiratory Protection6 citations · $250
1910.157Portable Fire Extinguishers4 citations · $0

Industry comparison

BLS 2024 survey: sign manufacturing reported 1.8 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 23.4%; NAICS 33995 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in GARNER, NC