Skip to content
SafetyRecord logoSafetyRecord

Inspection #113939128

Closed

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

The Occupational Safety and Health Administration (OSHA) conducted a planned inspection of DRESSER-RAND COMPANY at 100 Chemung St, Painted Post, NY 14870 on Jan 4, 1995. The inspection scope was complete. The case was closed on Jul 31, 1995.

OSHA documented 19 violations (13 serious, 6 other-than-serious) with total penalties on record of $7,875.

OSHA collected 431 air monitoring samples covering 24 substances during this inspection, including 1-Methoxy-2-propanol, 2-Butanone, Antimony and Compounds (as Sb), Beryllium and Beryllium Compounds (as Be), Chromium, Metal and Insoluble Salts, and 19 more.

This employer has 4 other OSHA inspections on record at this establishment.

Inspection Details

Inspection Number
113939128
Type
Planned (H)
Scope
Complete
Opened
Jan 4, 1995
Closed
Jul 31, 1995
Total Violations
19
Penalties on Record
$7,875
Initial Penalties
$10,125
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Establishment

Address
100 Chemung St, Painted Post, NY 14870
Industry
Not classified in OSHA's inspection record.

Other Inspections of This Employer4 on record

Other OSHA inspections of the same establishment. Linked via establishment ID (exact government key).

Enforcement Outcome

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page.

Status on Record
Closed

Inspection closed Jul 31, 1995.

Citations on Record
19

13 serious, 6 other-than-serious.

Initial Penalties
$10,125

Citation amounts as first recorded in OSHA's penalty fields.

Current Penalties
$7,875

Latest published amounts after changes in the enforcement process.

Chemical Exposure Sampling24 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
1-Methoxy-2-propanol53.1404 - 46.5998ppm
2-Butanone60ppm
Antimony and Compounds (as Sb)280mg/m³
Beryllium and Beryllium Compounds (as Be)280mg/m³
Chromium, Metal and Insoluble Salts280 - 0.0289mg/m³
Cobalt, Metal, Dust and Fume (as Co)280mg/m³
Copper Fume (as Cu)280 - 0.0585mg/m³
Cyclohexane40ppm
Ethyl Benzene40 - 0.12ppm
Hexone90 - 4.8324ppm
Iron Oxide Fume280 - 3.3966mg/m³
Lead, Inorganic (as Pb)280 - 0.0098mg/m³
Manganese Fume (as Mn)280 - 0.3298mg/m³
Methyl (n-amyl) ketone120 - 14.5167ppm
Molybdenum (as Mo), Insoluble Compounds (Total Dust)280 - 0.0033mg/m³
n-Butyl Alcohol50 - 16.6914ppm
Nickel, Metal and Insoluble compounds (as Ni)280 - 0.019mg/m³
Stoddard Solvent70 - 227mg/m³
Tin, inorganic compounds (except oxides) (as Sn)30 - 0.085mg/m³
Toluene190 - 18.8383ppm
Vanadium fume (as V2O5)280 - 0.0024mg/m³
VM and P Naphtha120 - 137.4mg/m³
Xylene90 - 37.7642ppm
Zinc Oxide Fume280 - 0.0196mg/m³

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Violations

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

CitationStandardTypeInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 B01
Serious$1,125$675Jul 3, 1995--
01002A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious$4,500$2,700Jul 3, 1995--
01002B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G06
Serious$0$0Jul 3, 1995--
01002C1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G08 I
Serious$0$0Jul 3, 1995--
01002D1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G08 IIA
Serious$0$0Jul 3, 1995--
01002E1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I02 I
Serious$0$0Jul 3, 1995--
01002F1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I02 IIB
Serious$0$0Jul 3, 1995--
01002G1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I05
Serious$0$0Jul 3, 1995--
01002H1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 M01
Serious$0$0Jul 3, 1995--
010031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Serious$900$900Jul 3, 1995--
010041910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01 I
Serious$1,575$1,575Jul 3, 1995--
010051910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious$900$900Jul 3, 1995--
010061910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious$1,125$1,125Jul 3, 1995--
010071910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other$0$0Jul 3, 1995--
020011910.133
Eye and Face Protection
OSHA citation code: 19100133 A05
Other$0$0Jul 3, 1995--
020021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 Q07
Other$0$0Jul 31, 1995--
020031910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B02 III
Other$0$0Jul 3, 1995--
020041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other$0$0Jul 3, 1995--
020051910.1025
Lead
OSHA citation code: 19101025 D02
Other$0$0Jul 3, 1995--

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Data Source and Methodology

Data synced daily

Data on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. On inspection pages, the status display follows the DOL inspection record first. If the DOL inspection feed includes a close date, we show the inspection as closed. If the inspection feed has no close date but all citation records tied to that inspection show a final order date, we label the page "Final Order Recorded" and disclose the citation dates instead of inferring a close date. Chemical exposure sampling data and OSHA Permissible Exposure Limits (PELs) are sourced from the OSHA Occupational Chemical Database, matched via IMIS analyte codes. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.