Skip to content
SafetyRecord logoSafetyRecord
LANGER MFG CO
$3,440
penalties
15
viol.
4
insp.

LANGER MFG CO

1025 7TH ST SW, Cedar Rapids, IA 52404

Inspections
4
Sep 1982 to May 1993 · 4 safety, 0 health
Violations
15
across 4 inspections
Penalties on record
$3,440
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 12, 1993Follow-Up (F) · Partial scope, Safety#115051526$00 viol.

Inspection #115051526

Dates

Opened
May 12, 1993
Closing Conference Date
May 12, 1993
Closed
May 12, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
57

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1025 7th Street S.w., Cedar Rapids, IA 52404
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Dec 1, 1992Planned (H) · Complete scope, Safety#115049215$3,00012 viol.

Inspection #115049215

Dates

Opened
Dec 1, 1992
Closing Conference Date
Jan 6, 1993
Closed
Oct 31, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
57

Violations and Penalties

Total Violations
12
Violation Types
9 serious, 3 other-than-serious
Initial Penalties
$9,000
Penalties on Record
$3,000
Site Address
1025 7th Street S.w., Cedar Rapids, IA 52404
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04
Serious110$750$300Mar 12, 1993--
010021910.176
Handling Materials - General
OSHA citation code: 19100176 A
Other16$750$200Feb 26, 1993--
010031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 M09
Serious14$750$300Mar 12, 1993--
01004A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious14$1,250$600Feb 26, 1993--
01004B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious24$0$0Feb 26, 1993--
010051910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IV
Serious14$750$300Mar 30, 1993--
010061910.217
Mechanical Power Presses
OSHA citation code: 19100217 D09 IV
Serious14$1,000$500Mar 30, 1993--
010071910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious14$750$150Feb 26, 1993--
010081910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious24$750$150Feb 26, 1993--
010091910.254
Arc Welding and Cutting
OSHA citation code: 19100254 D09 III
Serious14$750$300Feb 26, 1993--
010101910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Other110$750$0Feb 26, 1993--
020011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Other110$750$200Mar 12, 1993--

Failure to Abate Penalties4 citations, $8,000 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 4 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01001#115051526Jun 1, 1993$2,000Jun 24, 1993Mar 24, 1994
01002#115051526Jun 1, 1993$2,000Jun 24, 1993Mar 24, 1994
01004B#115051526Jun 1, 1993$2,000Jun 24, 1993Mar 24, 1994
01005#115051526Jun 1, 1993$2,000Jun 24, 1993Mar 24, 1994
Aug 4, 1983Accident (A) · Partial scope, Safety#17136037$3001 viol.

Inspection #17136037

Dates

Opened
Aug 4, 1983
Closing Conference Date
Aug 5, 1983
Closed
Sep 13, 1983

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
26

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$420
Penalties on Record
$300
Site Address
1025 7th St Sw, Cedar Rapids, IA 52404
Industry
Not classified in OSHA's inspection record.

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious1-$420$300Aug 22, 1983--
Sep 23, 1982Planned (H) · Complete scope, Safety#17154873$1402 viol.

Inspection #17154873

Dates

Opened
Sep 23, 1982
Closing Conference Date
Sep 23, 1982
Closed
Dec 10, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
35

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$200
Penalties on Record
$140
Site Address
1025 7th St South West, Cedar Rapids, IA 52404
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious2-$200$140Nov 12, 1982--
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious2-$0$0Nov 12, 1982--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus4 citations · $440
1910.212General Requirements for All Machines (Machine Guarding)3 citations · $900
1910.147Control of Hazardous Energy (Lockout/Tagout)2 citations · $500

Other inspected employers in Cedar Rapids, IA

All employers in Cedar Rapids →