Skip to content
SafetyRecord logoSafetyRecord
HOUSEHOLD METALS, INC.
$44,117
penalties
70
viol.
9
insp.

HOUSEHOLD METALS, INC.

645 E. ERIE AVENUE, PHILADELPHIA, PA 19134NAICS 332321 Metal Window and Door Manufacturing

Inspections
9
Oct 1997 to May 2024 · 3 safety, 6 health
Violations
70
across 9 inspections
Penalties on record
$44,117
latest amounts in DOL records
By classification
Serious 53Willful 0Repeat 1Other 16

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 1, 2024Referral (C) · Partial scope, Health#347453219$11,2921 viol.

Inspection #347453219

Dates

Opened
May 1, 2024
Closing Conference Date
May 1, 2024
Final Order
Dec 5, 2024
Closed
Jun 27, 2025

Inspection

Advance Notice
Yes
Owner Type
Private
Union Status
No
Number of Employees
75
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$11,292
Penalties on Record
$11,292
Site Address
645 E. Erie Avenue, Philadelphia, PA 19134
Industry
332321 Metal Window and Door Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious262$11,292$11,292Dec 19, 2024-Dec 5, 2024
Mar 6, 2024Complaint (B) · Partial scope, Health#347326183$20,3257 viol.

Inspection #347326183

Dates

Opened
Mar 6, 2024
Closing Conference Date
Mar 6, 2024
Final Order
Sep 26, 2024
Closed
Jun 27, 2025

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
75
Related Activity
1 complaint

Violations and Penalties

Total Violations
7
Violation Types
7 serious
Initial Penalties
$33,876
Penalties on Record
$20,325
Site Address
645 E. Erie Avenue, Philadelphia, PA 19134
Industry
332321 Metal Window and Door Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Serious14$11,292$6,775Dec 2, 2024-Sep 26, 2024
01002A1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious14$11,292$6,775Oct 17, 2024-Sep 26, 2024
01002B1910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Serious14$0$0Oct 17, 2024-Sep 26, 2024
01002C1910.134
Respiratory Protection
OSHA citation code: 19100134 K01
Serious14$0$0Oct 17, 2024-Sep 26, 2024
01003A1910.1200
Hazard Communication
OSHA citation code: 19101200 F06 II
Serious12$11,292$6,775Oct 17, 2024-Sep 26, 2024

Showing the 5 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Feb 16, 2023Planned (H) · No Inspection scope, Health#346509953$00 viol.

Inspection #346509953

Dates

Opened
Feb 16, 2023
Closing Conference Date
Not recorded
Closed
Jun 16, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
74

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
645 E. Erie Avenue, Philadelphia, PA 19134
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Apr 10, 2014Planned (H) · Partial scope, Health#339685315$2,8004 viol.

Inspection #339685315

Dates

Opened
Apr 10, 2014
Closing Conference Date
Apr 17, 2014
Final Order
Nov 17, 2014
Closed
Jul 24, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
70

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$5,600
Penalties on Record
$2,800
Site Address
645 E. Erie Avenue, Philadelphia, PA 19134
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 E07 II
Serious11$2,800$2,800Jan 5, 2015-Nov 17, 2014
01001C1910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Serious26$0$0Jan 5, 2015-Nov 17, 2014
01001D1910.134
Respiratory Protection
OSHA citation code: 19100134 G01 I A
Serious24$0$0Jan 5, 2015-Nov 17, 2014
010021910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B02 III
Other14$2,800$0Oct 30, 2014-Nov 17, 2014
May 23, 2008Planned (H) · Partial scope, Health#310721295$01 viol.

Inspection #310721295

Dates

Opened
May 23, 2008
Closing Conference Date
Jul 2, 2008
Closed
Mar 4, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
645 East Eric Avenue, Philadelphia, PA 19134
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Chromic Acid and Chromates (as CrO3)40mg/m³
Chromium (VI) - TWA40mg/m³

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 G02 I
Other11$0$0Jul 29, 2008--
Dec 19, 2007Planned (H) · Complete scope, Safety#310721097$4,00013 viol.

Inspection #310721097

Dates

Opened
Dec 19, 2007
Closing Conference Date
Apr 30, 2008
Closed
Jan 13, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
13
Violation Types
10 serious, 1 repeat, 2 other-than-serious
Initial Penalties
$10,350
Penalties on Record
$4,000
Site Address
645 East Eric Avenue, Philadelphia, PA 19134
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Serious11$900$500Jun 11, 2008--
01002A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Serious13$900$500Jun 11, 2008--
01002B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G07
Serious13$0$0Jun 11, 2008--
01003A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L02 II
Serious15$900$500Jun 11, 2008--
01003B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L06
Serious95$0$0Jun 11, 2008--

Showing the 5 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Dec 19, 2007Planned (H) · Complete scope, Safety#310719265$00 viol.

Inspection #310719265

Dates

Opened
Dec 19, 2007
Closing Conference Date
Apr 30, 2008
Closed
Dec 31, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
645 E. Erie Avenue, Philadelphia, PA 19134
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Aug 11, 2005Planned (H) · Complete scope, Health#116023946$1,50014 viol.

Inspection #116023946

Dates

Opened
Aug 11, 2005
Closing Conference Date
Sep 29, 2005
Closed
Jun 21, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
61

Violations and Penalties

Total Violations
14
Violation Types
9 serious, 5 other-than-serious
Initial Penalties
$3,000
Penalties on Record
$1,500
Site Address
645 East Eric Avenue, Philadelphia, PA 19134
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Methylene bisphenyl isocyanate40mg/m³

Violations

Violation list (5 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Serious115$875$500Jan 15, 2006--
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 K02
Serious140$0$0Jan 15, 2006--
01002A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Serious130$525$250Mar 31, 2006--
01002B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious110$0$0Mar 31, 2006--
010031910.176
Handling Materials - General
OSHA citation code: 19100176 B
Serious13$525$150Oct 7, 2005--

Showing the 5 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 7, 1997Planned (H) · Complete scope, Safety#301446621$4,20030 viol.

Inspection #301446621

Dates

Opened
Oct 7, 1997
Closing Conference Date
Dec 4, 1997
Closed
May 24, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
31

Violations and Penalties

Total Violations
30
Violation Types
23 serious, 7 other-than-serious
Initial Penalties
$8,750
Penalties on Record
$4,200
Site Address
645 East Eric Avenue, Philadelphia, PA 19134
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 30 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.106
Flammable Liquids
OSHA citation code: 19100106 D04 I
Serious13$750$500Apr 20, 1998--
01001B1910.106
Flammable Liquids
OSHA citation code: 19100106 D04 IV
Serious12$0$0Apr 20, 1998--
01002A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B03
Serious22$750$500Apr 20, 1998--
01002B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Serious22$0$0Apr 20, 1998--
01002C1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B06
Serious22$0$0Apr 20, 1998--

Showing the 5 violations listed first by citation identifier. This inspection has 30 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 9 of 9, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection12 citations · $10,075
1910.107Spray Finishing Using Flammable and Combustible Materials11 citations · $8,775
1910.95Occupational Noise Exposure5 citations · $0

Chemical exposure sampling

Samples
12
Substances
3
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer7.8
Industry average3.3
Penalties per inspection
This employer$4,902
Industry average$2,308

Fabricated Metal Product Manufacturing, 47,182 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: metal window and door manufacturing reported 3.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.3%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in PHILADELPHIA, PA