UNIPAR, INCORPORATED
25 ROYAL STREET, REEDSVILLE, PA 17084 · NAICS 326199 All Other Plastics Product Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Oct 17, 2006#116204736Oct 17, 2006Planned (H) · Complete scope, Safety#116204736$2,73011 viol.11 violations$2,730 in penalties
Inspection #116204736
Dates
- Opened
- Oct 17, 2006
- Closing Conference Date
- Dec 4, 2006
- Closed
- Jan 19, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 24
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 10 serious, 1 other-than-serious
- Initial Penalties
- $3,900
- Penalties on Record
- $2,730
- Site Address
- 130 Royal Street, Reedsville, PA 17084
- Industry
- 326199 All Other Plastics Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (8 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 1 | $600 | $420 | Jan 12, 2007 | - | - |
| 01001B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 II | Serious | 1 | 1 | $0 | $0 | Jan 12, 2007 | - | - |
| 01001C | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C07 I | Serious | 1 | 1 | $0 | $0 | Jan 12, 2007 | - | - |
| 01002 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 L01 I | Serious | 2 | 2 | $600 | $420 | Jan 12, 2007 | - | - |
| 01003 | 1910.243 Guarding of Portable Powered Tools OSHA citation code: 19100243 C03 | Serious | 1 | 1 | $750 | $525 | Jan 12, 2007 | - | - |
| 01004 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Serious | 2 | 2 | $750 | $525 | Jan 12, 2007 | - | - |
| 01005 | 1910.332 Electrical Safety-Related Work Practices - Training OSHA citation code: 19100332 B01 | Serious | 1 | 2 | $750 | $525 | Jan 12, 2007 | - | - |
| 01006A | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Serious | 1 | 18 | $450 | $315 | Jan 12, 2007 | - | - |
Showing the 8 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Nov 13, 2002#305834657Nov 13, 2002Planned (H) · Partial scope, Safety#305834657$5805 viol.5 violations$580 in penalties
Inspection #305834657
Dates
- Opened
- Nov 13, 2002
- Closing Conference Date
- Nov 13, 2002
- Closed
- Dec 18, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 37
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 serious
- Initial Penalties
- $890
- Penalties on Record
- $580
- Site Address
- 130 Royal Street, Reedsville, PA 17084
- Industry
- 326199 All Other Plastics Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 1 | $445 | $290 | Nov 13, 2002 | - | - |
| 01001B | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 1 | $0 | $0 | Nov 13, 2002 | - | - |
| 01002A | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 1 | 1 | $445 | $290 | Nov 13, 2002 | - | - |
| 01002B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Serious | 1 | 1 | $0 | $0 | Nov 13, 2002 | - | - |
| 01002C | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 I | Serious | 1 | 1 | $0 | $0 | Dec 23, 2002 | - | - |
Jan 14, 1997#116163296Jan 14, 1997Follow-Up (F) · Partial scope, Health#116163296$36,25510 viol.10 violations$36,255 in penalties
Inspection #116163296
Dates
- Opened
- Jan 14, 1997
- Closing Conference Date
- Jun 10, 1997
- Contested
- Jul 24, 1997
- Final Order
- May 16, 1998
- Closed
- Apr 1, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 28
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 1 serious, 5 willful, 3 repeat, 1 other-than-serious
- Initial Penalties
- $72,165
- Penalties on Record
- $36,255
- Site Address
- 130 Royal Street, Reedsville, PA 17084
- Industry
- 326199 All Other Plastics Product Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (8 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 1 | 1 | $765 | $390 | Jan 14, 1997 | Jul 24, 1997 | May 16, 1998 |
| 02001A | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 B | Willful | 1 | 25 | $33,000 | $16,500 | Aug 3, 1997 | Jul 24, 1997 | May 16, 1998 |
| 02001B | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 C01 I | Willful | 1 | 25 | $0 | $0 | Aug 3, 1997 | Jul 24, 1997 | May 16, 1998 |
| 02001C | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 G02 I | Willful | 1 | 25 | $0 | $0 | Aug 3, 1997 | Jul 24, 1997 | May 16, 1998 |
| 02002A | 1910.184 Slings OSHA citation code: 19100184 C09 | Willful | 2 | 9 | $33,000 | $16,500 | Aug 3, 1997 | Jul 24, 1997 | May 16, 1998 |
| 02002B | 1910.184 Slings OSHA citation code: 19100184 E03 I | Willful | 2 | 9 | $0 | $0 | Aug 3, 1997 | Jul 24, 1997 | May 16, 1998 |
| 03001A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Repeat | 1 | 1 | $1,800 | $955 | Jan 14, 1997 | Jul 24, 1997 | May 16, 1998 |
| 03001B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Repeat | 1 | 1 | $0 | $0 | Jan 14, 1997 | Jul 24, 1997 | May 16, 1998 |
Showing the 8 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
May 16, 1996#116157777May 16, 1996Follow-Up (F) · Partial scope, Health#116157777$04 viol.4 violations$0 in penalties
Inspection #116157777
Dates
- Opened
- May 16, 1996
- Closing Conference Date
- May 16, 1996
- Contested
- Jul 15, 1996
- Final Order
- Oct 19, 1996
- Closed
- Apr 1, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 25
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 serious
- Initial Penalties
- $800
- Penalties on Record
- $0
- Site Address
- 130 Royal Street, Reedsville, PA 17084
- Industry
- 326199 All Other Plastics Product Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 C01 I | Serious | 1 | 1 | $800 | $0 | Jul 14, 1996 | Jul 15, 1996 | Oct 19, 1996 |
| 01001B | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 G02 VIID | Serious | 1 | 1 | $0 | $0 | Jul 14, 1996 | Jul 15, 1996 | Oct 19, 1996 |
| 01001C | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 G02 VIIK | Serious | 1 | 1 | $0 | $0 | Jul 14, 1996 | Jul 15, 1996 | Oct 19, 1996 |
| 01001D | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 G02 VIIL | Serious | 1 | 1 | $0 | $0 | Jul 14, 1996 | Jul 15, 1996 | Oct 19, 1996 |
Dec 11, 1995#116160540Dec 11, 1995Complaint (B) · Complete scope, Health#116160540$022 viol.22 violations$0 in penalties
Inspection #116160540
Dates
- Opened
- Dec 11, 1995
- Closing Conference Date
- Dec 11, 1995
- Contested
- Jul 5, 1996
- Final Order
- Oct 19, 1996
- Closed
- Apr 1, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 20
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 22
- Violation Types
- 12 serious, 1 repeat, 9 other-than-serious
- Initial Penalties
- $5,000
- Penalties on Record
- $0
- Site Address
- 130 Royal Street, Reedsville, PA 17084
- Industry
- 326199 All Other Plastics Product Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (8 of 22 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 I02 I | Serious | 1 | 1 | $600 | $0 | Feb 23, 1996 | Jul 5, 1996 | Oct 19, 1996 |
| 01001B | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 C01 | Serious | 2 | 3 | $0 | $0 | Feb 23, 1996 | Jul 5, 1996 | Oct 19, 1996 |
| 01002A | 1910.101 Compressed Gases (General Requirements) OSHA citation code: 19100101 B | Serious | 1 | 1 | $800 | $0 | Feb 16, 1996 | Jul 5, 1996 | Oct 19, 1996 |
| 01002B | 1910.101 Compressed Gases (General Requirements) OSHA citation code: 19100101 B | Serious | 1 | 1 | $0 | $0 | Feb 16, 1996 | Jul 5, 1996 | Oct 19, 1996 |
| 01003A | 1910.184 Slings OSHA citation code: 19100184 C09 | Serious | 3 | 2 | $1,400 | $0 | Mar 17, 1996 | Jul 5, 1996 | Oct 19, 1996 |
| 01003B | 1910.184 Slings OSHA citation code: 19100184 E03 I | Serious | 3 | 5 | $0 | $0 | Mar 17, 1996 | Jul 5, 1996 | Oct 19, 1996 |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 2 | 2 | $600 | $0 | Mar 2, 1996 | Jul 5, 1996 | Oct 19, 1996 |
| 01005A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 3 | 3 | $600 | $0 | Mar 2, 1996 | Jul 5, 1996 | Oct 19, 1996 |
Showing the 8 violations listed first by citation identifier. This inspection has 22 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Failure to Abate Penalties11 citations, $67,328 in FTA penalties on record
OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 11 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.
| Citation | FTA Inspection | FTA Issuance | FTA Penalty | FTA Contest | FTA Final Order |
|---|---|---|---|---|---|
| 01001B | #116163296 | Jul 1, 1997 | $13,500 | Aug 1, 1997 | May 16, 1998 |
| 01003A | #116157777 | Jun 11, 1996 | - | Aug 1, 1997 | Oct 19, 1996 |
| 01003B | #116157777 | Jun 11, 1996 | - | Aug 1, 1997 | Oct 19, 1996 |
| 01004 | #116157777 | Jun 11, 1996 | - | Aug 1, 1997 | Oct 19, 1996 |
Showing the 4 FTA rows present in the first 8 citations on this inspection. OSHA's record shows 11 total citations with FTA activity for this inspection. The complete list is available at enforcedata.dol.gov.
Sep 1, 1995#123182891Sep 1, 1995Planned (H) · No Inspection scope, Safety#123182891$00 viol.0 violations$0 in penalties
Inspection #123182891
Dates
- Opened
- Sep 1, 1995
- Closing Conference Date
- Sep 1, 1995
- Closed
- Oct 6, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 19
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 25 Royal Street, Reedsville, PA 17084
- Industry
- 326199 All Other Plastics Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
6 inspections, 1995 to 2006. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Plastics and Rubber Products Manufacturing, 12,985 employers with OSHA inspections. Arithmetic from DOL records.