Skip to content
SafetyRecord logoSafetyRecord
MCCLAIN'S CUSTOM CABINETS, INC.
$1,641
penalties
31
viol.
4
insp.

MCCLAIN'S CUSTOM CABINETS, INC.

2467 AIRPORT ROAD, HOT SPRINGS, AR 71913

Inspections
4
Mar 1998 to Jan 2009 · 2 safety, 2 health
Violations
31
across 4 inspections
Penalties on record
$1,641
latest amounts in DOL records
By classification
Serious 24Willful 0Repeat 0Other 7

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 8, 2009Planned (H) · Partial scope, Safety#312738529$1,5006 viol.

Inspection #312738529

Dates

Opened
Jan 8, 2009
Closing Conference Date
Feb 11, 2009
Contested
Mar 23, 2009
Final Order
Oct 16, 2009
Closed
May 31, 2014

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 other-than-serious
Initial Penalties
$1,050
Penalties on Record
$1,500
Site Address
2467 Airport Road, Hot Springs, AR 71913
Industry
337110 Wood Kitchen Cabinet and Countertop Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010081910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious211$750$300Mar 16, 2009Mar 23, 2009Oct 16, 2009
01009A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious111$0$600Mar 9, 2009Mar 23, 2009Oct 16, 2009
01009B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 I01
Serious111$0$0Mar 9, 2009Mar 23, 2009Oct 16, 2009
01010A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious211$0$600Mar 16, 2009Mar 23, 2009Oct 16, 2009
01010B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IVA
Serious411$0$0Mar 16, 2009Mar 23, 2009Oct 16, 2009
020011904.29
Forms
OSHA citation code: 19040029 A
Other111$300$0Mar 9, 2009Mar 23, 2009Oct 16, 2009
May 13, 1999Follow-Up (F) · Partial scope, Health#123445660$00 viol.

Inspection #123445660

Dates

Opened
May 13, 1999
Closing Conference Date
May 13, 1999
Closed
May 14, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2467 Airport Road, Hot Springs, AR 71913
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Mar 5, 1998Complaint (B) · Partial scope, Safety#116486523$13119 viol.

Inspection #116486523

Dates

Opened
Mar 5, 1998
Closing Conference Date
Jul 6, 1998
Closed
Oct 23, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12
Related Activity
1 complaint

Violations and Penalties

Total Violations
19
Violation Types
18 serious, 1 other-than-serious
Initial Penalties
$12,450
Penalties on Record
$131
Site Address
2467 Airport Road, Hot Springs, AR 71913
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (12 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.36
Design and Construction Requirements for Exit Routes
OSHA citation code: 19100036 B04
Serious13$600$6Aug 18, 1998--
010021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Serious13$600$6Aug 11, 1998--
010031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Serious43$600$6Aug 18, 1998--
010041910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L
Serious11$450$5Aug 25, 1998--
010051910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 A09
Serious12$600$6Aug 18, 1998--
010061910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C01
Serious15$750$8Aug 18, 1998--
010071910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C02
Serious15$750$8Aug 18, 1998--
010081910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C03
Serious16$750$8Aug 18, 1998--
010091910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious25$750$8Aug 18, 1998--
010101910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious15$750$8Aug 18, 1998--
010111910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 I01
Serious12$750$8Aug 12, 1998--
010121910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious15$600$6Aug 18, 1998--

Showing the 12 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Mar 5, 1998Complaint (B) · Partial scope, Health#116485970$106 viol.

Inspection #116485970

Dates

Opened
Mar 5, 1998
Closing Conference Date
Jul 2, 1998
Closed
May 14, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12
Related Activity
1 complaint

Violations and Penalties

Total Violations
6
Violation Types
1 serious, 5 other-than-serious
Initial Penalties
$600
Penalties on Record
$10
Site Address
2467 Airport Road, Hot Springs, AR 71913
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC160.0471 - 8.15mg/m³
Particulates not otherwise regulated (Respirable Fraction)90 - 0.4312mg/m³
Particulates not otherwise regulated (Total Dust)90 - 8.15mg/m³
Sample WeightQC180 - 2.608mg

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious112$600$10Sep 29, 1998--
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other112$0$0Sep 15, 1998--
020021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other112$0$0Oct 5, 1998--
020031910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Other112$0$0Sep 20, 1998--
020041910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Other112$0$0Sep 29, 1998--
020051910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 F01
Other112$0$0Sep 29, 1998--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.213Woodworking Machinery Requirements9 citations · $654
1910.305Electrical - Wiring Methods, Components, and Equipment5 citations · $324
1910.132Personal Protective Equipment - General Requirements3 citations · $0

Chemical exposure sampling

Samples
52
Substances
4
Inspections
1

Industry comparison

BLS 2024 survey: wood kitchen cabinet and countertop manufacturing reported 3.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 13.2%; NAICS 33711 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in HOT SPRINGS, AR

All employers in HOT SPRINGS →