POWER AND CONTROL SYSTEMS CO., INC. AKA PACS
10 PITTSBURG AVE., MOUNT VERNON, OH 43050 · NAICS 335314 Relay and Industrial Control Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jun 15, 2007#310479795Jun 15, 2007Planned (H) · Complete scope, Safety#310479795$8,4009 viol.9 violations$8,400 in penalties
Inspection #310479795
Dates
- Opened
- Jun 15, 2007
- Closing Conference Date
- Jun 21, 2007
- Closed
- Aug 15, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 160
Violations and Penalties
- Total Violations
- 9
- Violation Types
- 7 serious, 2 other-than-serious
- Initial Penalties
- $8,400
- Penalties on Record
- $8,400
- Site Address
- 10 Pittsburg Ave., Mount Vernon, OH 43050
- Industry
- 335313 Switchgear and Switchboard Apparatus Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (9 of 9 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 IIB | Serious | 1 | 3 | $1,750 | $1,750 | Aug 12, 2007 | - | - |
| 01001B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 I | Serious | 1 | 4 | $0 | $0 | Aug 12, 2007 | - | - |
| 01002A | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H04 | Serious | 1 | 2 | $3,500 | $3,500 | Jul 20, 2007 | - | - |
| 01002B | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 I01 | Serious | 2 | 5 | $0 | $0 | Jul 20, 2007 | - | - |
| 01003 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 2 | 5 | $1,050 | $1,050 | Jul 23, 2007 | - | - |
| 01004 | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B04 III | Serious | 1 | 1 | $1,050 | $1,050 | Jul 23, 2007 | - | - |
| 01005 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 | Serious | 1 | 2 | $1,050 | $1,050 | Jul 23, 2007 | - | - |
| 02001 | 1904.29 Forms OSHA citation code: 19040029 B01 | Other | 1 | 1 | $0 | $0 | Jul 23, 2007 | - | - |
| 02002 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 B06 | Other | 1 | 2 | $0 | $0 | Jul 20, 2007 | - | - |
Oct 25, 2006#112528690Oct 25, 2006Complaint (B) · Partial scope, Health#112528690$1,9605 viol.5 violations$1,960 in penalties
Inspection #112528690
Dates
- Opened
- Oct 25, 2006
- Closing Conference Date
- Oct 25, 2006
- Closed
- Feb 5, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 150
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 4 serious, 1 other-than-serious
- Initial Penalties
- $2,800
- Penalties on Record
- $1,960
- Site Address
- 10 Pittsburg Ave., Mount Vernon, OH 43050
- Industry
- 335314 Relay and Industrial Control Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.134 Respiratory Protection OSHA citation code: 19100134 G01 IA | Serious | 1 | 1 | $1,750 | $1,225 | Dec 3, 2006 | - | - |
| 01001B | 1910.134 Respiratory Protection OSHA citation code: 19100134 K01 IV | Serious | 1 | 1 | $0 | $0 | Dec 3, 2006 | - | - |
| 01001C | 1910.134 Respiratory Protection OSHA citation code: 19100134 M02 IE | Serious | 1 | 1 | $0 | $0 | Dec 3, 2006 | - | - |
| 01002 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 | Serious | 1 | 1 | $1,050 | $735 | Dec 3, 2006 | - | - |
| 02001 | 1904.32 Annual Summary OSHA citation code: 19040032 A02 | Other | 1 | 4 | $0 | $0 | Dec 3, 2006 | - | - |
May 21, 2002#304366297May 21, 2002Planned (H) · Complete scope, Health#304366297$5,54619 viol.19 violations$5,546 in penalties
Inspection #304366297
Dates
- Opened
- May 21, 2002
- Closing Conference Date
- May 23, 2002
- Closed
- Aug 23, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 225
Violations and Penalties
- Total Violations
- 19
- Violation Types
- 11 serious, 8 other-than-serious
- Initial Penalties
- $12,325
- Penalties on Record
- $5,546
- Site Address
- 10 Pittsburg Ave., Mount Vernon, OH 43050
- Industry
- 335314 Relay and Industrial Control Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 3 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 3 | 0 | mg/m³ |
| Cadmium | 3 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 3 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 3 | 0 | mg/m³ |
| Copper Fume (as Cu) | 3 | 0.0041853 - 0.0161533 | mg/m³ |
| Gravimetric DeterminationQC | 2 | 0.3489 - 2.1982 | mg/m³ |
| Iron Oxide Fume | 3 | 0.4811223 - 0.9525879 | mg/m³ |
| Lead, Inorganic (as Pb) | 3 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 3 | 0.0122435 - 0.0492236 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 3 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 3 | 0 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 2 | 0.3489 - 2.1982 | mg/m³ |
| Sample WeightQC | 2 | 0.259 - 0.671 | mg |
| Vanadium fume (as V2O5) | 3 | 0 | mg/m³ |
| Zinc Oxide Fume | 3 | 0 | mg/m³ |
Violations
Violation list (10 of 19 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 D04 I | Serious | 1 | 2 | $1,700 | $765 | Jul 6, 2002 | - | - |
| 01002A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 II | Serious | 1 | 1 | $2,125 | $956 | Jul 6, 2002 | - | - |
| 01002B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C05 II | Serious | 1 | 1 | $0 | $0 | Jul 6, 2002 | - | - |
| 01002C | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C05 III | Serious | 1 | 1 | $0 | $0 | Jul 6, 2002 | - | - |
| 01002D | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 I | Serious | 1 | 1 | $0 | $0 | Jul 6, 2002 | - | - |
| 01003 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | 1 | $1,700 | $765 | Jul 6, 2002 | - | - |
| 01004 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 A04 | Serious | 1 | 1 | $1,275 | $574 | Aug 15, 2002 | - | - |
| 01005 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 1 | $1,275 | $574 | Jul 6, 2002 | - | - |
| 01006 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 B03 | Serious | 1 | 1 | $2,125 | $956 | Jul 6, 2002 | - | - |
| 01007A | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 1 | $2,125 | $956 | Jul 6, 2002 | - | - |
Showing the 10 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Sep 2, 1999#300535820Sep 2, 1999Planned (H) · Complete scope, Health#300535820$2,8059 viol.9 violations$2,805 in penalties
Inspection #300535820
Dates
- Opened
- Sep 2, 1999
- Closing Conference Date
- Sep 10, 1999
- Closed
- Feb 4, 2000
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 93
Violations and Penalties
- Total Violations
- 9
- Violation Types
- 7 serious, 2 other-than-serious
- Initial Penalties
- $4,675
- Penalties on Record
- $2,805
- Site Address
- 10 Pittsburg Ave., Mount Vernon, OH 43050
- Industry
- 335314 Relay and Industrial Control Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (9 of 9 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 I | Serious | 3 | 3 | $1,100 | $660 | Feb 1, 2000 | - | - |
| 01001B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 D11 | Serious | 1 | 3 | $0 | $0 | Feb 1, 2000 | - | - |
| 01002A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C02 | Serious | 1 | 3 | $1,100 | $660 | Nov 29, 1999 | - | - |
| 01002B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C03 | Serious | 1 | 3 | $0 | $0 | Nov 29, 1999 | - | - |
| 01002C | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C06 | Serious | 1 | 3 | $0 | $0 | Nov 29, 1999 | - | - |
| 01003 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 II | Serious | 1 | 15 | $1,375 | $825 | Oct 30, 1999 | - | - |
| 01004 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 | Serious | 1 | 2 | $1,100 | $660 | Nov 14, 1999 | - | - |
| 02001 | 1910.134 Respiratory Protection OSHA citation code: 19100134 C01 | Other | 1 | 3 | $0 | $0 | Feb 1, 2000 | - | - |
| 02002 | 1910.134 Respiratory Protection OSHA citation code: 19100134 D01 | Other | 1 | 3 | $0 | $0 | Nov 14, 1999 | - | - |
Aug 5, 1999#121912778Aug 5, 1999Planned (H) · Complete scope, Safety#121912778$11,20416 viol.16 violations$11,204 in penalties
Inspection #121912778
Dates
- Opened
- Aug 5, 1999
- Closing Conference Date
- Aug 19, 1999
- Closed
- Oct 8, 1999
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 95
Violations and Penalties
- Total Violations
- 16
- Violation Types
- 14 serious, 2 other-than-serious
- Initial Penalties
- $21,025
- Penalties on Record
- $11,204
- Site Address
- 10 Pittsburg Ave., Mount Vernon, OH 43050
- Industry
- 335314 Relay and Industrial Control Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (10 of 16 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 C01 | Serious | 1 | 2 | $1,375 | $688 | Oct 10, 1999 | - | - |
| 01002 | 1910.38 Emergency Action Plans OSHA citation code: 19100038 A01 | Serious | 1 | 95 | $825 | $413 | Oct 10, 1999 | - | - |
| 01003 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 1 | $825 | $413 | Oct 10, 1999 | - | - |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 8 | $1,375 | $688 | Oct 10, 1999 | - | - |
| 01005 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A02 | Serious | 1 | 2 | $1,100 | $550 | Sep 2, 1999 | - | - |
| 01006 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 5 | 10 | $1,375 | $688 | Sep 2, 1999 | - | - |
| 01008 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 1 | 10 | $1,375 | $1,375 | Aug 30, 1999 | - | - |
| 01009 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B01 I | Serious | 11 | 80 | $3,500 | $1,750 | Sep 23, 1999 | - | - |
| 01010 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 C | Serious | 1 | 4 | $1,375 | $688 | Aug 30, 1999 | - | - |
| 01011 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F | Serious | 3 | 50 | $825 | $413 | Sep 7, 1999 | - | - |
Showing the 10 violations listed first by citation identifier. This inspection has 16 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
5 inspections, 1999 to 2007. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Industry comparison
Electrical Equipment, Appliance, and Component Manufacturing, 4,523 employers with OSHA inspections. Arithmetic from DOL records.