Skip to content
SafetyRecord logoSafetyRecord
INDIANA BRIDGE
$10,500
penalties
70
viol.
6
insp.

INDIANA BRIDGE

1810 S MACEDONIA AVE, MUNCIE, IN 47302

Inspections
6
Jun 1982 to Jan 2023 · 6 safety, 0 health
Violations
70
across 6 inspections
Penalties on record
$10,500
latest amounts in DOL records
By classification
Serious 37Willful 0Repeat 0Other 33

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 6, 2023Referral (C) · Partial scope, Safety#346420839$00 viol.

Inspection #346420839

Dates

Opened
Jan 6, 2023
Closing Conference Date
Jan 10, 2023
Closed
Mar 17, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1810 S. Macedonia Avenue, Muncie, IN 47302
Industry
332312 Fabricated Structural Metal Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Feb 4, 1998Planned (H) · Complete scope, Safety#125392910$9,00040 viol.

Inspection #125392910

Dates

Opened
Feb 4, 1998
Closing Conference Date
Feb 4, 1998
Closed
Dec 2, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
45

Violations and Penalties

Total Violations
40
Violation Types
25 serious, 15 other-than-serious
Initial Penalties
$22,750
Penalties on Record
$9,000
Site Address
1810 S Macedonia Ave, Muncie, IN 47302
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 40 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.36
Design and Construction Requirements for Exit Routes
OSHA citation code: 19100036 B04
Serious36$2,500$1,250Mar 22, 1998--
01001B1910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 K02
Serious16$0$0Mar 22, 1998--
01002A1910.38
Emergency Action Plans
OSHA citation code: 19100038 A01
Other145$2,500$0Jun 1, 1998--
01002B1910.38
Emergency Action Plans
OSHA citation code: 19100038 A03 I
Other145$0$0Mar 22, 1998--
01002C1910.38
Emergency Action Plans
OSHA citation code: 19100038 B01
Other145$0$0Jun 1, 1998--
01003A1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IVC
Serious16$2,500$1,250Mar 22, 1998--
01003B1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IVA
Serious16$0$0Mar 22, 1998--
01004A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C02
Serious16$2,500$1,250Mar 22, 1998--

Showing the 8 violations listed first by citation identifier. This inspection has 40 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Apr 28, 1989Planned (H) · Complete scope, Safety#107950263$72018 viol.

Inspection #107950263

Dates

Opened
Apr 28, 1989
Closing Conference Date
Apr 28, 1989
Closed
Oct 11, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
67

Violations and Penalties

Total Violations
18
Violation Types
7 serious, 11 other-than-serious
Initial Penalties
$720
Penalties on Record
$720
Site Address
1810 S Macedonia Ave, Muncie, IN 47302
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 18 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious55$180$180Jul 27, 1989--
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F01
Serious11$0$0Jul 27, 1989--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious14$180$180Jun 23, 1989--
01003A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious12$180$180Jul 27, 1989--
01003B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious12$0$0Jul 27, 1989--
01004A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious11$180$180Jul 27, 1989--
01004B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious22$0$0Jul 27, 1989--
020011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 K02
Other18$0$0Jul 5, 1989--

Showing the 8 violations listed first by citation identifier. This inspection has 18 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

May 9, 1988Planned (H) · No Inspection scope, Safety#103987871$00 viol.

Inspection #103987871

Dates

Opened
May 9, 1988
Closing Conference Date
May 9, 1988
Closed
Aug 26, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1810 S Macedonia Ave, Muncie, IN 47302
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 28, 1987Planned (H) · No Inspection scope, Safety#103994356$00 viol.

Inspection #103994356

Dates

Opened
Jul 28, 1987
Closing Conference Date
Jul 28, 1987
Closed
Aug 18, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
5

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1810 S Macedonia Ave, Muncie, IN 47302
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jun 2, 1982Planned (H) · Complete scope, Safety#215176892$78012 viol.

Inspection #215176892

Dates

Opened
Jun 2, 1982
Closing Conference Date
Jun 15, 1982
Closed
Oct 27, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
104

Violations and Penalties

Total Violations
12
Violation Types
5 serious, 7 other-than-serious
Initial Penalties
$1,200
Penalties on Record
$780
Site Address
1810 South Macedonia, Muncie, IN 47302
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious1-$240$180Jul 7, 1982--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious1-$240$180Jul 7, 1982--
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Serious2-$480$240Oct 5, 1982--
01004A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious1-$240$180Jul 7, 1982--
01004B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious1-$0$0Jul 7, 1982--
020031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Other1-$0$0Jul 7, 1982--
020051910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G07
Other1-$0$0Jul 12, 1982--
020071910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G02
Other1-$0$0Jul 16, 1982--

Showing the 8 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus7 citations · $860
1910.303Electrical - General Requirements6 citations · $680
1910.1200Hazard Communication6 citations · $375

Industry comparison

BLS 2024 survey: fabricated structural metal manufacturing reported 3.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 7.9%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in MUNCIE, IN