LA CITY WATER & POWER
111 N. HOPE ST., LOS ANGELES, CA 90012 · NAICS 221122 Electric Power Distribution
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jul 16, 2003#126197144Jul 16, 2003Complaint (B) · Partial scope, Health#126197144$00 viol.0 violations$0 in penalties
Inspection #126197144
Dates
- Opened
- Jul 16, 2003
- Closing Conference Date
- Jul 17, 2003
- Closed
- Dec 3, 2003
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 10
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 4030 Crenshaw Blvd, Los Angeles, CA 90008
- Industry
- 221310 Water Supply and Irrigation Systems
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Jul 11, 2002#126157924Jul 11, 2002Complaint (B) · Partial scope, Safety#126157924$1851 viol.1 violation$185 in penalties
Inspection #126157924
Dates
- Opened
- Jul 11, 2002
- Closing Conference Date
- Jul 11, 2002
- Contested
- Jun 12, 2003
- Final Order
- Sep 30, 2003
- Closed
- Oct 9, 2003
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 100
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $185
- Penalties on Record
- $185
- Site Address
- 2311 Fairfax Ave., Los Angeles, CA 90016
- Industry
- 221122 Electric Power Distribution
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01002 | 3543 Control Mechanism for Hydraulic Lifts OSHA citation code: 3543 C | Other | 3 | 1 | $185 | $185 | Jan 12, 2003 | Jun 12, 2003 | Sep 30, 2003 |
Jun 21, 2002#126157874Jun 21, 2002Accident (A) · Partial scope, Safety#126157874$18,0001 viol.1 violation$18,000 in penalties
Inspection #126157874
Dates
- Opened
- Jun 21, 2002
- Closing Conference Date
- Jun 21, 2002
- Closed
- Nov 12, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 100
- Related Activity
- 1 accident
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 serious
- Initial Penalties
- $18,000
- Penalties on Record
- $18,000
- Site Address
- 10945 1/2 Le Conte Ave., Los Angeles, CA 90095
- Industry
- 221122 Electric Power Distribution
Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.
Incident Investigation Summaries
Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.
Burn - electrical fault
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 2320.2 Energized Equipment or Systems OSHA citation code: 23200002 A05 | Serious | 1 | 5 | $18,000 | $18,000 | Nov 15, 2002 | - | - |
Feb 13, 2002#126098722Feb 13, 2002Accident (A) · Complete scope, Safety#126098722$18,9002 viol.2 violations$18,900 in penalties
Inspection #126098722
Dates
- Opened
- Feb 13, 2002
- Closing Conference Date
- Aug 6, 2002
- Contested
- Feb 5, 2003
- Final Order
- Apr 9, 2004
- Closed
- Apr 9, 2004
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 100
- Related Activity
- 1 accident
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 1 serious, 1 other-than-serious
- Initial Penalties
- $36,000
- Penalties on Record
- $18,900
- Site Address
- W. Second St. & S. Vermont Ave., Los Angeles, CA 90004
- Industry
- 221122 Electric Power Distribution
Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.
Incident Investigation Summaries
Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.
Burn - electrical fault in underground cable
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 02001 | 2943 Work on or in Proximity to Underground High-Voltage Cables, Conductors or Equipment OSHA citation code: 2943 F04 | Serious | 1 | 8 | $18,000 | $18,000 | Aug 9, 2002 | Feb 5, 2003 | Apr 9, 2004 |
| 03001 | 3556 General OSHA citation code: 3556 B | Other | 1 | 8 | $18,000 | $900 | Aug 9, 2002 | Feb 5, 2003 | Apr 9, 2004 |
Feb 8, 2002#126098375Feb 8, 2002Accident (A) · Partial scope, Safety#126098375$1,1252 viol.2 violations$1,125 in penalties
Inspection #126098375
Dates
- Opened
- Feb 8, 2002
- Closing Conference Date
- Jul 23, 2002
- Contested
- Jan 21, 2003
- Closed
- Sep 13, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 4
- Related Activity
- 1 accident
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 1 serious, 1 other-than-serious
- Initial Penalties
- $18,375
- Penalties on Record
- $1,125
- Site Address
- 100 N. Los Angeles St., Los Angeles, CA 90013
- Industry
- 221122 Electric Power Distribution
Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.
Incident Investigation Summaries
Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.
Electric shock - direct contact with energized parts
Enforcement Outcome
Citation contest activity appears on Jan 21, 2003. Final orders are recorded through Jul 19, 2004. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 342 Reporting Work-Connected Fatalities and Serious Injuries OSHA citation code: 342 A | Other | 1 | 1 | $375 | $375 | Jul 26, 2002 | - | - |
| 02001 | 2944 Work on or in Proximity to Conductors and Equipment Located in High-Voltage Stations, or Switchyards OSHA citation code: 2944 H01 D | Serious | 1 | 1 | $18,000 | $750 | Jul 26, 2002 | Jan 21, 2003 | Jul 19, 2004 |
Feb 8, 2002#126098367Feb 8, 2002Accident (A) · Partial scope, Safety#126098367$3,7502 viol.2 violations$3,750 in penalties
Inspection #126098367
Dates
- Opened
- Feb 8, 2002
- Closing Conference Date
- Jul 23, 2002
- Contested
- Aug 7, 2002
- Closed
- Sep 13, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 4
- Related Activity
- 1 accident
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 1 serious, 1 other-than-serious
- Initial Penalties
- $3,750
- Penalties on Record
- $3,750
- Site Address
- 3922 S. Normandie Ave, Rear Alley, Los Angeles, CA 90037
- Industry
- 221122 Electric Power Distribution
Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.
Incident Investigation Summaries
Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.
Burn - electrical fault in overhead line
Enforcement Outcome
Citation contest activity appears on Aug 7, 2002. Final orders are recorded through May 26, 2004. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 342 Reporting Work-Connected Fatalities and Serious Injuries OSHA citation code: 342 A | Other | 1 | 1 | $375 | $375 | Jul 29, 2002 | - | - |
| 02001 | 2944 Work on or in Proximity to Conductors and Equipment Located in High-Voltage Stations, or Switchyards OSHA citation code: 2944 C02 | Serious | 1 | 1 | $3,375 | $3,375 | Jul 26, 2002 | Aug 7, 2002 | May 26, 2004 |
Sep 7, 2000#126220557Sep 7, 2000Complaint (B) · Partial scope, Health#126220557$3751 viol.1 violation$375 in penalties
Inspection #126220557
Dates
- Opened
- Sep 7, 2000
- Closing Conference Date
- Nov 6, 2000
- Closed
- May 15, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 10
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $375
- Penalties on Record
- $375
- Site Address
- 2460 San Marcos Dr., Los Angeles, CA 90068
- Industry
- 221122 Electric Power Distribution
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 5162 Emergency Eyewash and Shower Equipment OSHA citation code: 5162 D | Other | 2 | 3 | $375 | $375 | Dec 6, 2000 | - | - |
May 8, 2000#126097724May 8, 2000Accident (A) · Partial scope, Safety#126097724$7,2001 viol.1 violation$7,200 in penalties
Inspection #126097724
Dates
- Opened
- May 8, 2000
- Closing Conference Date
- Aug 18, 2000
- Contested
- Sep 11, 2000
- Final Order
- Jul 11, 2001
- Closed
- Nov 2, 2001
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 8,000
- Related Activity
- 1 accident
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 serious
- Initial Penalties
- $18,000
- Penalties on Record
- $7,200
- Site Address
- 1350 S. Wall St., Los Angeles, CA 90013
- Industry
- 221122 Electric Power Distribution
Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.
Incident Investigation Summaries
Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.
Employee caught finger in cable cutter
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 02001 | 3556 General OSHA citation code: 3556 C | Serious | 1 | 4 | $18,000 | $7,200 | Sep 13, 2000 | Sep 11, 2000 | Jul 11, 2001 |
May 8, 2000#126097716May 8, 2000Accident (A) · Partial scope, Safety#126097716$00 viol.0 violations$0 in penalties
Inspection #126097716
Dates
- Opened
- May 8, 2000
- Closing Conference Date
- May 17, 2000
- Closed
- May 17, 2000
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 8,000
- Related Activity
- 1 accident
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 666 N. Edinburgh Ave., Los Angeles, CA 90048
- Industry
- 221122 Electric Power Distribution
Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.
Apr 3, 2000#126097682Apr 3, 2000Accident (A) · No Inspection scope, Safety#126097682$00 viol.0 violations$0 in penalties
Inspection #126097682
Dates
- Opened
- Apr 3, 2000
- Closing Conference Date
- Not recorded
- Closed
- Apr 20, 2000
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Not recorded
- Number of Employees
- Not recorded
- Related Activity
- 1 accident
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- W. Seventh St. & S. Bixel Ave., Los Angeles, CA 90017
- Industry
- 221122 Electric Power Distribution
Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
50 inspections, 2000 to 2024. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
The timeline shows the 50 most recent of 76 inspections with a recorded opening date.
Standards cited
Industry comparison
Utilities, 14,301 employers with OSHA inspections. Arithmetic from DOL records.