ANBEL CORPORATION
TEX HIWAY 48 AT MARINE WAY PORT OF BROWNSVILLE, BROWNSVILLE, TX 78520
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jul 15, 1986#100306497Jul 15, 1986Follow-Up (F) · No Inspection scope, Health#100306497$00 viol.0 violations$0 in penalties
Inspection #100306497
Dates
- Opened
- Jul 15, 1986
- Closing Conference Date
- Jul 15, 1986
- Closed
- Jan 14, 1988
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- Not recorded
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Tx Hwy 48 At Marine Way Port Of, Brownsville, TX 78520
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Feb 12, 1985#1608835Feb 12, 1985Planned (H) · Complete scope, Health#1608835$10522 viol.22 violations$105 in penalties
Inspection #1608835
Dates
- Opened
- Feb 12, 1985
- Closing Conference Date
- Mar 6, 1985
- Closed
- Feb 28, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 12
Violations and Penalties
- Total Violations
- 22
- Violation Types
- 12 serious, 10 other-than-serious
- Initial Penalties
- $210
- Penalties on Record
- $105
- Site Address
- Tex Hiway 48 At Marine Way Port Of Brownsville, Brownsville, TX 78520
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling16 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 8 | 0.074 - 0.3284 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 8 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 8 | 0 | mg/m³ |
| Chromic Acid and Chromates (as CrO3) | 2 | 0 | |
| Chromium, Metal and Insoluble Salts | 8 | 0.3294 - 1.6128 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 8 | 0.0045 - 0.0209 | mg/m³ |
| Copper Fume (as Cu) | 8 | 0 | mg/m³ |
| Iron Oxide Fume | 8 | 0.0508 - 0.1187 | mg/m³ |
| Lead, Inorganic (as Pb) | 8 | 1.4396 - 2.6768 | mg/m³ |
| Manganese Fume (as Mn) | 8 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 8 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 8 | 0 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 8 | 0 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 2 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 8 | 0 | mg/m³ |
| Zinc Oxide Fume | 8 | 0 - 0.019 | mg/m³ |
Violations
Violation list (16 of 22 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Serious | 1 | 2 | $120 | $60 | May 13, 1985 | - | - |
| 01002A | 1910.1025 Lead OSHA citation code: 19101025 C01 | Serious | 1 | 2 | $90 | $45 | Jun 3, 1985 | - | - |
| 01002B | 1910.1025 Lead OSHA citation code: 19101025 D02 | Serious | 1 | 2 | $0 | $0 | Jun 3, 1985 | - | - |
| 01002C | 1910.1025 Lead OSHA citation code: 19101025 E01 II | Serious | 1 | 2 | $0 | $0 | Jun 3, 1985 | - | - |
| 01002D | 1910.1025 Lead OSHA citation code: 19101025 F02 I | Serious | 1 | 2 | $0 | $0 | May 13, 1985 | - | - |
| 01002E | 1910.1025 Lead OSHA citation code: 19101025 F02 III | Serious | 1 | 2 | $0 | $0 | May 13, 1985 | - | - |
| 01002F | 1910.1025 Lead OSHA citation code: 19101025 F03 I | Serious | 1 | 2 | $0 | $0 | May 13, 1985 | - | - |
| 01002G | 1910.1025 Lead OSHA citation code: 19101025 F04 I | Serious | 1 | 2 | $0 | $0 | May 20, 1985 | - | - |
| 01002H | 1910.1025 Lead OSHA citation code: 19101025 F04 II | Serious | 1 | 2 | $0 | $0 | May 13, 1985 | - | - |
| 01002I | 1910.1025 Lead OSHA citation code: 19101025 G01 | Serious | 1 | 2 | $0 | $0 | May 13, 1985 | - | - |
| 01002J | 1910.1025 Lead OSHA citation code: 19101025 G02 I | Serious | 1 | 2 | $0 | $0 | May 13, 1985 | - | - |
| 01002K | 1910.1025 Lead OSHA citation code: 19101025 I03 I | Serious | 1 | 2 | $0 | $0 | May 13, 1985 | - | - |
| 02001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVA | Other | 1 | 2 | $0 | $0 | May 13, 1985 | - | - |
| 02002 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C02 | Other | 1 | 2 | $0 | $0 | May 6, 1985 | - | - |
| 02003 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C08 | Other | 1 | 2 | $0 | $0 | Jun 3, 1985 | - | - |
| 02004 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C08 | Other | 1 | 2 | $0 | $0 | May 13, 1985 | - | - |
Showing the 16 violations listed first by citation identifier. This inspection has 22 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Oct 25, 1984#888677Oct 25, 1984Planned (H) · Records Only scope, Safety#888677$00 viol.0 violations$0 in penalties
Inspection #888677
Dates
- Opened
- Oct 25, 1984
- Closing Conference Date
- Oct 25, 1984
- Closed
- Oct 29, 1984
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 12
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Sh 48 At Marine Way, Brownsville, TX 78520
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
3 inspections, 1984 to 1986. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.