C & D POWER SYSTEMS
1835 ROCKDALE INDUSTRIAL BLVD., CONYERS, GA 30207 · NAICS 335911 Storage Battery Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Sep 17, 1991#110104403Sep 17, 1991Follow-Up (F) · Partial scope, Health#110104403$00 viol.0 violations$0 in penalties
Inspection #110104403
Dates
- Opened
- Sep 17, 1991
- Closing Conference Date
- Sep 17, 1991
- Closed
- Nov 22, 1991
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 135
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1835 Rockdale Industrial Blvd., Conyers, GA 30207
- Industry
- 335911 Storage Battery Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Dec 6, 1990#110104262Dec 6, 1990Follow-Up (F) · Complete scope, Health#110104262$4805 viol.5 violations$480 in penalties
Inspection #110104262
Dates
- Opened
- Dec 6, 1990
- Closing Conference Date
- Jan 18, 1991
- Closed
- Dec 16, 1991
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 145
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 3 serious, 2 other-than-serious
- Initial Penalties
- $480
- Penalties on Record
- $480
- Site Address
- 1835 Rockdale Industrial Blvd., Conyers, GA 30207
- Industry
- 335911 Storage Battery Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Lead, Inorganic (as Pb) | 5 | 0.013 - 0.13 | mg/m³ |
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.1025 Lead OSHA citation code: 19101025 C01 | Serious | 1 | 1 | $240 | $240 | Sep 15, 1991 | - | - |
| 01001B | 1910.1025 Lead OSHA citation code: 19101025 E01 | Serious | 1 | 1 | $0 | $0 | Sep 15, 1991 | - | - |
| 01002 | 1910.1025 Lead OSHA citation code: 19101025 F03 I | Serious | 1 | 1 | $240 | $240 | Feb 27, 1991 | - | - |
| 02001 | 1910.1025 Lead OSHA citation code: 19101025 D06 III | Other | 3 | 6 | $0 | $0 | Sep 15, 1991 | - | - |
| 02002 | 1910.1025 Lead OSHA citation code: 19101025 D06 II | Other | 1 | 3 | $0 | $0 | Sep 15, 1991 | - | - |
Dec 6, 1989#18337824Dec 6, 1989Follow-Up (F) · Partial scope, Health#18337824$00 viol.0 violations$0 in penalties
Inspection #18337824
Dates
- Opened
- Dec 6, 1989
- Closing Conference Date
- Dec 7, 1989
- Closed
- Feb 27, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 150
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1835 Rockdale Industrial Blvd., Conyers, GA 30207
- Industry
- 335911 Storage Battery Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Lead, Inorganic (as Pb) | 19 | 0.0074 - 0.26 | mg/m³ |
Nov 1, 1989#18337832Nov 1, 1989Monitoring (D) · Partial scope, Health#18337832$00 viol.0 violations$0 in penalties
Inspection #18337832
Dates
- Opened
- Nov 1, 1989
- Closing Conference Date
- Nov 7, 1989
- Closed
- Jan 5, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 150
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1835 Rockdale Industrial Blvd., Conyers, GA 30207
- Industry
- 335911 Storage Battery Manufacturing
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling2 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Lead, Inorganic (as Pb) | 7 | 0 - 0.036 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 6 | 0 | mg/m³ |
May 19, 1989#18316281May 19, 1989Monitoring (D) · Partial scope, Health#18316281$00 viol.0 violations$0 in penalties
Inspection #18316281
Dates
- Opened
- May 19, 1989
- Closing Conference Date
- May 19, 1989
- Closed
- Jun 27, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 155
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1835 Rockdale Industrial Blvd., Conyers, GA 30207
- Industry
- 335911 Storage Battery Manufacturing
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Oct 19, 1988#102829975Oct 19, 1988Monitoring (D) · Partial scope, Health#102829975$9001 viol.1 violation$900 in penalties
Inspection #102829975
Dates
- Opened
- Oct 19, 1988
- Closing Conference Date
- Oct 20, 1988
- Closed
- Dec 27, 1988
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 165
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 serious
- Initial Penalties
- $900
- Penalties on Record
- $900
- Site Address
- 1835 Rockdale Industrial Blvd., Conyers, GA 30207
- Industry
- 335911 Storage Battery Manufacturing
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.1025 Lead OSHA citation code: 19101025 H01 | Serious | 2 | 16 | $900 | $900 | Dec 12, 1988 | - | - |
Apr 20, 1988#102828001Apr 20, 1988Follow-Up (F) · Partial scope, Health#102828001$7004 viol.4 violations$700 in penalties
Inspection #102828001
Dates
- Opened
- Apr 20, 1988
- Closing Conference Date
- Apr 27, 1988
- Closed
- Mar 27, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 153
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 3 serious, 1 other-than-serious
- Initial Penalties
- $700
- Penalties on Record
- $700
- Site Address
- 1835 Rockdale Industrial Blvd., Conyers, GA 30207
- Industry
- 335911 Storage Battery Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Chemical Exposure Sampling2 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Lead, Inorganic (as Pb) | 13 | 0 - 0.28 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 12 | 0 | mg/m³ |
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.134 Respiratory Protection OSHA citation code: 19100134 E05 I | Serious | 3 | 3 | $700 | $700 | Sep 21, 1988 | - | - |
| 01001B | 1910.1025 Lead OSHA citation code: 19101025 C01 | Serious | 3 | 3 | $0 | $0 | Sep 21, 1988 | - | - |
| 01001C | 1910.1025 Lead OSHA citation code: 19101025 E01 | Serious | 8 | 24 | $0 | $0 | Dec 4, 1989 | - | - |
| 02001 | 1910.134 Respiratory Protection OSHA citation code: 19100134 E05 I | Other | 2 | 2 | $0 | $0 | Sep 21, 1988 | - | - |
Failure to Abate Penalties1 citation, $200 in FTA penalties on record
OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 1 citation issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.
| Citation | FTA Inspection | FTA Issuance | FTA Penalty | FTA Contest | FTA Final Order |
|---|---|---|---|---|---|
| 01001C | #18337824 | Feb 1, 1990 | $200 | - | - |
Oct 20, 1987#101215556Oct 20, 1987Monitoring (D) · Partial scope, Health#101215556$00 viol.0 violations$0 in penalties
Inspection #101215556
Dates
- Opened
- Oct 20, 1987
- Closing Conference Date
- Oct 21, 1987
- Closed
- Dec 29, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 144
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1835 Rockdale Industrial Blvd., Conyers, GA 30207
- Industry
- 335911 Storage Battery Manufacturing
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling2 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Lead, Inorganic (as Pb) | 13 | 0.0068 - 0.08 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 13 | 0 | mg/m³ |
Apr 30, 1987#101209773Apr 30, 1987Monitoring (D) · Partial scope, Health#101209773$00 viol.0 violations$0 in penalties
Inspection #101209773
Dates
- Opened
- Apr 30, 1987
- Closing Conference Date
- Apr 30, 1987
- Closed
- Jul 2, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 100
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1835 Rockdale Industrial Blvd., Conyers, GA 30207
- Industry
- 335911 Storage Battery Manufacturing
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Aug 7, 1986#101099943Aug 7, 1986Monitoring (D) · Partial scope, Health#101099943$00 viol.0 violations$0 in penalties
Inspection #101099943
Dates
- Opened
- Aug 7, 1986
- Closing Conference Date
- Aug 13, 1986
- Closed
- Sep 17, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 154
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1835 Rockdale Industrial Blvd., Conyers, GA 30207
- Industry
- 335911 Storage Battery Manufacturing
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling2 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Lead, Inorganic (as Pb) | 1716P / 1A | 0 - 0.34 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 1816P / 2A | 0 | mg/m³ |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
11 inspections, 1986 to 1991. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
Electrical Equipment, Appliance, and Component Manufacturing, 4,599 employers with OSHA inspections. Arithmetic from DOL records.