Skip to content
SafetyRecord logoSafetyRecord
XOMOX CORPORATION
$4,100
penalties
29
viol.
8
insp.

XOMOX CORPORATION

4444 COOPER ROAD, BLUE ASH, OH 45242NAICS 332919 Other Metal Valve and Pipe Fitting Manufacturing

Inspections
8
Jan 1985 to Jun 2000 · 5 safety, 3 health
Violations
29
across 8 inspections
Penalties on record
$4,100
latest amounts in DOL records
By classification
Serious 11Willful 0Repeat 0Other 18

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 16, 2000Referral (C) · Partial scope, Safety#18051201$8002 viol.

Inspection #18051201

Dates

Opened
Jun 16, 2000
Closing Conference Date
Jun 22, 2000
Contested
Jul 20, 2000
Final Order
Mar 12, 2001
Closed
Mar 28, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
280
Related Activity
1 referral

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$1,875
Penalties on Record
$800
Site Address
4444 Cooper Road, Blue Ash, OH 45242
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010021910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 K02
Serious16$1,875$800Jul 5, 2000Jul 20, 2000Mar 12, 2001
020011910.156
Fire Brigades
OSHA citation code: 19100156 B01
Other112$0$0Jul 26, 2000Jul 20, 2000Mar 12, 2001
Oct 28, 1997Complaint (B) · Partial scope, Safety#121988430$00 viol.

Inspection #121988430

Dates

Opened
Oct 28, 1997
Closing Conference Date
Oct 28, 1997
Closed
Oct 28, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
300
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4444 Cooper Road, Blue Ash, OH 45242
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

May 29, 1996Complaint (B) · Partial scope, Safety#102588225$1,6005 viol.

Inspection #102588225

Dates

Opened
May 29, 1996
Closing Conference Date
May 30, 1996
Closed
Aug 8, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
340
Related Activity
1 complaint

Violations and Penalties

Total Violations
5
Violation Types
1 serious, 4 other-than-serious
Initial Penalties
$7,500
Penalties on Record
$1,600
Site Address
4444 Cooper Road, Blue Ash, OH 45242
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Other11$1,875$400Jul 20, 1996--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Other11$1,875$400Jul 20, 1996--
010031910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious11$1,875$400Jun 25, 1996--
010041910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IIIA
Other11$1,875$400Jul 20, 1996--
020021910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Other11$0$0Jun 21, 1996--
Mar 28, 1990Complaint (B) · Partial scope, Health#103241980$04 viol.

Inspection #103241980

Dates

Opened
Mar 28, 1990
Closing Conference Date
Mar 28, 1990
Closed
Sep 18, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
375
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$800
Penalties on Record
$0
Site Address
4444 Cooper Road, Blue Ash, OH 45242
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Methylene bisphenyl isocyanate20.0128 - 0.0158mg/m³

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other111$300$0Apr 23, 1990--
010021910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q02
Other111$200$0Jun 17, 1990--
010031910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q05
Other111$300$0Apr 23, 1990--
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other11$0$0Apr 20, 1990--
Mar 17, 1989Complaint (B) · Partial scope, Safety#101693521$00 viol.

Inspection #101693521

Dates

Opened
Mar 17, 1989
Closing Conference Date
Mar 22, 1989
Closed
Mar 31, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
375
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4444 Cooper Road, Blue Ash, OH 45242
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Mar 10, 1987Complaint (B) · Partial scope, Health#101693257$9006 viol.

Inspection #101693257

Dates

Opened
Mar 10, 1987
Closing Conference Date
Mar 11, 1987
Contested
Apr 15, 1987
Final Order
Dec 21, 1987
Closed
Oct 26, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
266
Related Activity
1 complaint

Violations and Penalties

Total Violations
6
Violation Types
3 serious, 3 other-than-serious
Initial Penalties
$1,260
Penalties on Record
$900
Site Address
4444 Cooper Road, Blue Ash, OH 45242
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.96
Ionizing Radiation
OSHA citation code: 19100096 B01
Serious12$420$300Mar 29, 1987Apr 15, 1987Dec 21, 1987
01002A1910.96
Ionizing Radiation
OSHA citation code: 19100096 D01
Other12$420$0Mar 29, 1987Apr 15, 1987Dec 21, 1987
01002B1910.96
Ionizing Radiation
OSHA citation code: 19100096 D02
Serious12$0$300Mar 29, 1987Apr 15, 1987Dec 21, 1987
01003A1910.96
Ionizing Radiation
OSHA citation code: 19100096 I02
Serious12$420$300Apr 5, 1987Apr 15, 1987Dec 21, 1987
01003B1910.96
Ionizing Radiation
OSHA citation code: 19100096 I02
Other12$0$0Apr 5, 1987Apr 15, 1987Dec 21, 1987
020011910.96
Ionizing Radiation
OSHA citation code: 19100096 L01 I
Other12$0$0Mar 29, 1987Apr 15, 1987Dec 21, 1987
Sep 6, 1985Complaint (B) · Complete scope, Health#2381010$80012 viol.

Inspection #2381010

Dates

Opened
Sep 6, 1985
Closing Conference Date
Sep 12, 1985
Closed
Oct 31, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
367
Related Activity
1 complaint

Violations and Penalties

Total Violations
12
Violation Types
6 serious, 6 other-than-serious
Initial Penalties
$1,710
Penalties on Record
$800
Site Address
4444 Cooper Road, Blue Ash, OH 45242
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling16 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Cadmium Fume (as Cd)20mg/m³
Chromium, Metal and Insoluble Salts20mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20mg/m³
Iron Oxide Fume20 - 0.0063mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20mg/m³
Methyl Chloroform715.9 - 41.8ppm
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Particulates not otherwise regulated (Respirable Fraction)20mg/m³
Trichloroethylene50ppm
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20mg/m³

Violations

Violation list (6 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.94
Ventilation
OSHA citation code: 19100094 D09 I
Serious15$540$200Sep 26, 1985--
01002A1910.94
Ventilation
OSHA citation code: 19100094 D09 II
Serious15$540$300Sep 26, 1985--
01002B1910.94
Ventilation
OSHA citation code: 19100094 D09 III
Serious15$0$0Sep 26, 1985--
01002C1910.94
Ventilation
OSHA citation code: 19100094 D09 IV
Serious15$0$0Sep 26, 1985--
01002D1910.94
Ventilation
OSHA citation code: 19100094 D09 V
Serious15$0$0Sep 26, 1985--
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious15$630$300Sep 26, 1985--

Showing the 6 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jan 7, 1985Planned (H) · Records Only scope, Safety#2484954$00 viol.

Inspection #2484954

Dates

Opened
Jan 7, 1985
Closing Conference Date
Jan 7, 1985
Closed
Jan 7, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
346

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4444 Cooper Rd, Blue Ash, OH 45242
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.96Ionizing Radiation6 citations · $900
1910.94Ventilation6 citations · $500
1910.147Control of Hazardous Energy (Lockout/Tagout)4 citations · $1,600

Chemical exposure sampling

Samples
42
Substances
17
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer3.6
Industry average3.3
Penalties per inspection
This employer$513
Industry average$2,288

Fabricated Metal Product Manufacturing, 48,574 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in BLUE ASH, OH

All employers in BLUE ASH →