EAST WINDSOR MUA SEWER FACILITY
$0
penalties
28
viol.
2
insp.

EAST WINDSOR MUA SEWER FACILITY

EAST WINDSOR MUA SEWER FACILITY, HIGHTSTOWN, NJ 08520NAICS 221320 Sewage Treatment Facilities

Inspections
2
Oct 2005 to Jan 2006 · 2 safety, 0 health
Violations
28
across 2 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 22Willful 0Repeat 0Other 6

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 23, 2006Follow-Up (F) · Partial scope, Safety#309645570$00 viol.

Inspection #309645570

Dates

Opened
Jan 23, 2006
Closing Conference Date
Jan 23, 2006
Closed
Jan 23, 2006

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
13

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
East Windsor Mua Sewer Facility, Hightstown, NJ 08520
Industry
221320 Sewage Treatment Facilities

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Oct 31, 2005Planned (H) · Complete scope, Safety#309101863$028 viol.

Inspection #309101863

Dates

Opened
Oct 31, 2005
Closing Conference Date
Oct 31, 2005
Closed
Jan 23, 2006

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
13

Violations and Penalties

Total Violations
28
Violation Types
22 serious, 6 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
East Windsor Mua Sewer Facility, Hightstown, NJ 08520
Industry
221320 Sewage Treatment Facilities

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (25 of 28 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 B01
Serious113$0$0Jan 20, 2006--
010021910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 C
Serious113$0$0Jan 20, 2006--
010031910.23
Ladders
OSHA citation code: 19100023 A08
Serious113$0$0Jan 20, 2006--
010041910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 A03
Serious313$0$0Jan 20, 2006--
010051910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B06
Serious113$0$0Jan 20, 2006--
010061910.106
Flammable Liquids
OSHA citation code: 19100106 G08
Serious113$0$0Jan 20, 2006--
010071910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Serious113$0$0Jan 20, 2006--
010081910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C04
Serious113$0$0Jan 20, 2006--
010091910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious313$0$0Jan 20, 2006--
010101910.169
Air Receivers
OSHA citation code: 19100169 B02
Serious113$0$0Jan 20, 2006--
010111910.176
Handling Materials - General
OSHA citation code: 19100176 C
Serious213$0$0Jan 20, 2006--
010121910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J03
Serious413$0$0Jan 20, 2006--
010131910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious113$0$0Jan 20, 2006--
010141910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious113$0$0Jan 20, 2006--
010151910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious113$0$0Jan 20, 2006--
010161910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious113$0$0Jan 20, 2006--
010171910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01 I
Serious113$0$0Nov 15, 2005--
010181910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious113$0$0Jan 20, 2006--
010191910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious113$0$0Jan 20, 2006--
010201910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious113$0$0Jan 20, 2006--
010211910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J02 II
Serious713$0$0Jan 20, 2006--
010226A0033
OSHA citation code: 6A0033 A
Serious113$0$0Jan 20, 2006--
020011904.29
Forms
OSHA citation code: 19040029 A
Other213$0$0Jan 20, 2006--
020021910.38
Emergency Action Plans
OSHA citation code: 19100038 B
Other113$0$0Jan 20, 2006--
020031910.39
Fire Prevention Plans
OSHA citation code: 19100039 B
Other113$0$0Jan 20, 2006--

Showing the 25 violations listed first by citation identifier. This inspection has 28 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $0
1910.37Maintenance, Safeguards, and Operational Features for Exit Routes2 citations · $0
1910.215Abrasive Wheel Machinery2 citations · $0

Industry comparison

Violations per inspection
This employer14.0
Industry average2.0
Penalties per inspection
This employer$0
Industry average$2,041

Utilities, 14,269 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: sewage treatment facilities reported 1.7 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 40.1%; NAICS 22132 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in HIGHTSTOWN, NJ

All employers in HIGHTSTOWN →