PHIL GREEN CONTRACTOR, INCORPORATED
8321 ATLANTIC BLVD., JACKSONVILLE, FL 32256 · NAICS 337110 Wood Kitchen Cabinet and Countertop Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Sep 19, 2006#310027784Sep 19, 2006Referral (C) · Partial scope, Health#310027784$73115 viol.15 violations$731 in penalties
Inspection #310027784
Dates
- Opened
- Sep 19, 2006
- Closing Conference Date
- Nov 15, 2006
- Closed
- Jan 1, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 10
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 15
- Violation Types
- 8 serious, 7 other-than-serious
- Initial Penalties
- $1,125
- Penalties on Record
- $731
- Site Address
- 8321 Atlantic Blvd., Jacksonville, FL 32256
- Industry
- 337110 Wood Kitchen Cabinet and Countertop Manufacturing
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Chemical Exposure Sampling8 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Ethyl Benzene | 4 | 0 - 2.345408 | ppm |
| Isobutyl Alcohol | 4 | 0.935904 - 8.14337 | ppm |
| Methyl Alcohol | 5 | 0 | ppm |
| n-Butyl Acetate | 4 | 0 - 3.256145 | ppm |
| n-Butyl Alcohol | 4 | 0.51779 - 3.587184 | ppm |
| Trimethylbenzene (mixed isomers) | 4 | 0 - 1.18885 | ppm |
| VM and P Naphtha | 4 | 0 | mg/m³ |
| Xylene | 4 | 0.378871 - 7.181865 | ppm |
Violations
Violation list (15 of 15 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C02 | Serious | 1 | 2 | $300 | $195 | Jan 30, 2007 | - | - |
| 01001B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C03 | Serious | 1 | 2 | $0 | $0 | Jan 30, 2007 | - | - |
| 01001C | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C06 | Serious | 1 | 2 | $0 | $0 | Jan 30, 2007 | - | - |
| 01002 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 E09 | Serious | 1 | 2 | $300 | $195 | Jan 30, 2007 | - | - |
| 01003 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 F03 | Serious | 1 | 2 | $300 | $195 | Jan 30, 2007 | - | - |
| 01004A | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Serious | 1 | 2 | $225 | $146 | Jan 30, 2007 | - | - |
| 01004B | 1910.1200 Hazard Communication OSHA citation code: 19101200 G01 | Serious | 1 | 2 | $0 | $0 | Nov 21, 2006 | - | - |
| 01004C | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 | Serious | 1 | 2 | $0 | $0 | Nov 21, 2006 | - | - |
| 02001 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G07 | Other | 1 | 2 | $0 | $0 | Jan 30, 2007 | - | - |
| 02002A | 1910.134 Respiratory Protection OSHA citation code: 19100134 C01 | Other | 1 | 2 | $0 | $0 | Jan 30, 2007 | - | - |
| 02002B | 1910.134 Respiratory Protection OSHA citation code: 19100134 E01 | Other | 1 | 2 | $0 | $0 | Jan 30, 2007 | - | - |
| 02002C | 1910.134 Respiratory Protection OSHA citation code: 19100134 F01 | Other | 1 | 2 | $0 | $0 | Jan 30, 2007 | - | - |
| 02002D | 1910.134 Respiratory Protection OSHA citation code: 19100134 G01 IA | Other | 1 | 1 | $0 | $0 | Jan 30, 2007 | - | - |
| 02002E | 1910.134 Respiratory Protection OSHA citation code: 19100134 H02 I | Other | 1 | 1 | $0 | $0 | Jan 30, 2007 | - | - |
| 02002F | 1910.134 Respiratory Protection OSHA citation code: 19100134 K03 | Other | 1 | 2 | $0 | $0 | Jan 30, 2007 | - | - |
Sep 8, 2006#310027750Sep 8, 2006Complaint (B) · Complete scope, Safety#310027750$1,3508 viol.8 violations$1,350 in penalties
Inspection #310027750
Dates
- Opened
- Sep 8, 2006
- Closing Conference Date
- Sep 8, 2006
- Closed
- May 23, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 4
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 8
- Violation Types
- 5 serious, 3 other-than-serious
- Initial Penalties
- $2,250
- Penalties on Record
- $1,350
- Site Address
- 8321 Atlantic Blvd., Jacksonville, FL 32256
- Industry
- 337110 Wood Kitchen Cabinet and Countertop Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (8 of 8 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C01 | Serious | 1 | 4 | $1,500 | $900 | Nov 6, 2006 | - | - |
| 01001B | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C02 | Serious | 1 | 4 | $0 | $0 | Nov 6, 2006 | - | - |
| 01001C | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C03 | Serious | 1 | 4 | $0 | $0 | Nov 6, 2006 | - | - |
| 01002 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 N03 | Serious | 1 | 4 | $375 | $225 | Jan 12, 2007 | - | - |
| 01003 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 1 | 10 | $375 | $225 | Jan 31, 2007 | - | - |
| 02001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 D01 | Other | 1 | 10 | $0 | $0 | Jan 31, 2007 | - | - |
| 02002 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 | Other | 2 | 4 | $0 | $0 | Nov 6, 2006 | - | - |
| 02003 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Other | 1 | 4 | $0 | $0 | Jan 22, 2007 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
2 inspections, 2006 to 2006. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Industry comparison
Furniture and Related Product Manufacturing, 12,436 employers with OSHA inspections. Arithmetic from DOL records.
BLS 2024 survey: wood kitchen cabinet and countertop manufacturing reported 3.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 13.2%; NAICS 33711 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source