CENTRAL DENVER IRONWORKS, INC.
$17,463
penalties
40
viol.
5
insp.

CENTRAL DENVER IRONWORKS, INC.

4245 FOX STREET, DENVER, CO 80216NAICS 332312 Fabricated Structural Metal Manufacturing

Inspections
5
Mar 1998 to Jun 2010 · 1 safety, 4 health
Violations
40
across 5 inspections
Penalties on record
$17,463
latest amounts in DOL records
By classification
Serious 31Willful 0Repeat 0Other 9

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 3, 2010Referral (C) · Partial scope, Health#313419590$5635 viol.

Inspection #313419590

Dates

Opened
Jun 3, 2010
Closing Conference Date
Aug 30, 2010
Closed
Nov 5, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23
Related Activity
1 referral

Violations and Penalties

Total Violations
5
Violation Types
4 serious, 1 other-than-serious
Initial Penalties
$1,125
Penalties on Record
$563
Site Address
4245 Fox Street, Denver, CO 80216
Industry
332323 Ornamental and Architectural Metal Work Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)90mg/m³
Beryllium and Beryllium Compounds (as Be)90mg/m³
Cadmium90mg/m³
Chromium, Metal and Insoluble Salts90mg/m³
Cobalt, Metal, Dust and Fume (as Co)90mg/m³
Copper Fume (as Cu)90 - 0.0414147mg/m³
Iron Oxide Fume90.1933862 - 13.7255287mg/m³
Lead, Inorganic (as Pb)90mg/m³
Manganese Fume (as Mn)90.014911 - 3.4246mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)90mg/m³
Nickel, Metal and Insoluble compounds (as Ni)90mg/m³
Vanadium fume (as V2O5)90 - 0.0094336mg/m³
Zinc Oxide Fume90 - 0.1173269mg/m³

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious13$375$188Nov 5, 2010--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C06
Serious12$300$150Nov 5, 2010--
010031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Serious12$225$112Sep 16, 2010--
010041910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B02 III
Serious117$225$113Nov 5, 2010--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 I05 IV
Other13$0$0Nov 5, 2010--
Mar 30, 2010Planned (H) · Partial scope, Safety#313417735$9004 viol.

Inspection #313417735

Dates

Opened
Mar 30, 2010
Closing Conference Date
Mar 30, 2010
Closed
Aug 17, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 2 other-than-serious
Initial Penalties
$1,625
Penalties on Record
$900
Site Address
4245 Fox Street, Denver, CO 80216
Industry
332323 Ornamental and Architectural Metal Work Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04
Other123$375$150Aug 1, 2010--
01001B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06
Other123$0$0Aug 1, 2010--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious623$625$375Aug 1, 2010--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious623$625$375Aug 1, 2010--
Jul 29, 2008Follow-Up (F) · Partial scope, Health#311905954$00 viol.

Inspection #311905954

Dates

Opened
Jul 29, 2008
Closing Conference Date
Jul 29, 2008
Closed
Aug 4, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4245 Fox Street, Denver, CO 80216
Industry
332312 Fabricated Structural Metal Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Apr 23, 2007Complaint (B) · Partial scope, Health#310465661$10,50010 viol.

Inspection #310465661

Dates

Opened
Apr 23, 2007
Closing Conference Date
Sep 12, 2007
Closed
Aug 6, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50
Related Activity
1 complaint

Violations and Penalties

Total Violations
10
Violation Types
5 serious, 5 other-than-serious
Initial Penalties
$17,500
Penalties on Record
$10,500
Site Address
4245 Fox Street, Denver, CO 80216
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling3 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Chromic Acid and Chromates (as CrO3)30.002075 - 0.026045mg/m³
Chromium (VI) - TWA30.001079 - 0.013544mg/m³
Gravimetric DeterminationQC41.502 - 21.5075mg/m³
Sample WeightQC41.149 - 15.722mg
Silica, Crystalline Quartz (Respirable Fraction)40%

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 D01 III
Other22$2,500$1,500Sep 14, 2007--
01003A1910.1026
Chromium (VI)
OSHA citation code: 19101026 C
Serious11$2,500$1,500Nov 17, 2007--
010041910.1026
Chromium (VI)
OSHA citation code: 19101026 E01
Serious12$2,500$1,500Nov 17, 2007--
010051910.1026
Chromium (VI)
OSHA citation code: 19101026 G01 I
Serious12$2,500$1,500Oct 3, 2007--
010061910.1026
Chromium (VI)
OSHA citation code: 19101026 H01
Other12$2,500$1,500Oct 3, 2007--
01007A1910.1026
Chromium (VI)
OSHA citation code: 19101026 I05
Other11$2,500$1,500Oct 3, 2007--
01007B1910.1026
Chromium (VI)
OSHA citation code: 19101026 J01 I
Serious12$0$0Nov 30, 2007--
01008A1910.1026
Chromium (VI)
OSHA citation code: 19101026 K01 IA
Serious12$2,500$1,500Nov 30, 2007--
02001A1910.1026
Chromium (VI)
OSHA citation code: 19101026 D04 I
Other11$0$0Oct 3, 2007--
02001B1910.1026
Chromium (VI)
OSHA citation code: 19101026 D04 II
Other11$0$0Oct 3, 2007--
Mar 2, 1998Complaint (B) · Partial scope, Health#302066030$5,50021 viol.

Inspection #302066030

Dates

Opened
Mar 2, 1998
Closing Conference Date
Apr 6, 1998
Contested
Apr 23, 1998
Final Order
Oct 26, 1998
Closed
Aug 23, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
30
Related Activity
1 complaint

Violations and Penalties

Total Violations
21
Violation Types
20 serious, 1 other-than-serious
Initial Penalties
$21,000
Penalties on Record
$5,500
Site Address
4245 Fox Street, Denver, CO 80216
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)80mg/m³
Beryllium and Beryllium Compounds (as Be)80mg/m³
Chromium, Metal and Insoluble Salts80mg/m³
Cobalt, Metal, Dust and Fume (as Co)80mg/m³
Copper Fume (as Cu)80.0013 - 0.0158mg/m³
Iron Oxide Fume80.2379 - 1.5917mg/m³
Lead, Inorganic (as Pb)80mg/m³
Manganese Fume (as Mn)80.0176 - 0.2605mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)80mg/m³
Nickel, Metal and Insoluble compounds (as Ni)80mg/m³
Silica, Crystalline Quartz (Respirable Fraction)649 - 76%
Vanadium fume (as V2O5)80mg/m³
Zinc Oxide Fume80.0069 - 0.0568mg/m³

Violations

Violation list (10 of 21 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious12$2,500$475Sep 15, 1998Apr 23, 1998Oct 26, 1998
01002A1910.94
Ventilation
OSHA citation code: 19100094 A05 IIB
Serious22$2,500$475Sep 15, 1998Apr 23, 1998Oct 23, 1998
01002B1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious12$0$0Sep 15, 1998Apr 23, 1998Oct 26, 1998
01002C1910.1000
Air Contaminants
OSHA citation code: 19101000 C
Serious22$0$0Sep 15, 1998Apr 23, 1998Oct 26, 1998
010031910.94
Ventilation
OSHA citation code: 19100094 A05 V
Serious12$1,000$325Sep 15, 1998Apr 23, 1998Oct 26, 1998
010041910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious18$1,250$325Sep 15, 1998Apr 23, 1998Oct 26, 1998
01005A1910.106
Flammable Liquids
OSHA citation code: 19100106 E06 I
Serious11$1,000$325Sep 15, 1998Apr 23, 1998Oct 26, 1998
01005B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G07
Serious11$0$0Sep 15, 1998Apr 23, 1998Oct 26, 1998
010061910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Serious110$1,000$325Sep 15, 1998Apr 23, 1998Oct 26, 1998
010071910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious11$1,250$325Sep 15, 1998Apr 23, 1998Oct 26, 1998

Showing the 10 violations listed first by citation identifier. This inspection has 21 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1026Chromium (VI)9 citations · $9,000
1910.134Respiratory Protection3 citations · $1,500
1910.212General Requirements for All Machines (Machine Guarding)3 citations · $1,075

Chemical exposure sampling

Samples
237
Substances
18
Inspections
3

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer8.0
Industry average3.3
Penalties per inspection
This employer$3,493
Industry average$2,308

Fabricated Metal Product Manufacturing, 47,284 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in DENVER, CO