URBAN GREEN BUILDERS
961 MAIN STREET, BRIDGEPORT, CT 06604 · NAICS 236118 Residential Remodelers
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jul 10, 2007#311058465Jul 10, 2007Follow-Up (F) · Partial scope, Safety#311058465$7,5004 viol.4 violations$7,500 in penalties
Inspection #311058465
Dates
- Opened
- Jul 10, 2007
- Closing Conference Date
- Jul 10, 2007
- Closed
- Dec 30, 2009
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 4
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 3 serious, 1 repeat
- Initial Penalties
- $7,500
- Penalties on Record
- $7,500
- Site Address
- 961 Main Street, Bridgeport, CT 06604
- Industry
- 236220 Commercial and Institutional Building Construction
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1926.350 Gas Welding and Cutting OSHA citation code: 19260350 A09 | Serious | 1 | 1 | $1,500 | $1,500 | Sep 21, 2007 | - | - |
| 01001B | 1926.350 Gas Welding and Cutting OSHA citation code: 19260350 A10 | Serious | 1 | 1 | $0 | $0 | Sep 21, 2007 | - | - |
| 01002 | 1926.403 Electrical - General Requirements (Construction) OSHA citation code: 19260403 I02 I | Serious | 7 | 1 | $3,000 | $3,000 | Sep 21, 2007 | - | - |
| 02001 | 1926.153 Liquefied Petroleum Gas (LP-Gas) OSHA citation code: 19260153 H10 | Repeat | 1 | 1 | $3,000 | $3,000 | Oct 5, 2007 | - | - |
Jul 10, 2007#109178798Jul 10, 2007Follow-Up (F) · Partial scope, Safety#109178798$12,0004 viol.4 violations$12,000 in penalties
Inspection #109178798
Dates
- Opened
- Jul 10, 2007
- Closing Conference Date
- Jul 10, 2007
- Closed
- Oct 15, 2008
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 1 serious, 3 repeat
- Initial Penalties
- $12,000
- Penalties on Record
- $12,000
- Site Address
- 963-1019 Main Street, Bridgeport, CT 06604
- Industry
- 236220 Commercial and Institutional Building Construction
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.304 Woodworking Tools OSHA citation code: 19260304 F | Serious | 1 | 2 | $1,500 | $1,500 | Jul 27, 2007 | - | - |
| 02001 | 1926.501 Fall Protection - Duty to Have Fall Protection OSHA citation code: 19260501 B14 | Repeat | 11 | 2 | $7,500 | $7,500 | Jul 27, 2007 | - | - |
| 02002A | 1926.502 Fall Protection Systems Criteria and Practices OSHA citation code: 19260502 I03 | Repeat | 1 | 2 | $3,000 | $3,000 | Jul 27, 2007 | - | - |
| 02002B | 1926.502 Fall Protection Systems Criteria and Practices OSHA citation code: 19260502 I04 | Repeat | 1 | 2 | $0 | $0 | Jul 27, 2007 | - | - |
Mar 9, 2007#310649843Mar 9, 2007Referral (C) · Partial scope, Safety#310649843$21,0009 viol.9 violations$21,000 in penalties
Inspection #310649843
Dates
- Opened
- Mar 9, 2007
- Closing Conference Date
- Mar 9, 2007
- Closed
- Nov 17, 2008
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 3
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 9
- Violation Types
- 8 serious, 1 repeat
- Initial Penalties
- $21,000
- Penalties on Record
- $21,000
- Site Address
- 961 Main Street, Bridgeport, CT 06604
- Industry
- 236220 Commercial and Institutional Building Construction
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (7 of 9 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1926.150 Fire Protection (Construction) OSHA citation code: 19260150 C01 VI | Serious | 1 | 1 | $900 | $900 | May 31, 2007 | - | - |
| 01001B | 1926.150 Fire Protection (Construction) OSHA citation code: 19260150 C01 VIII | Serious | 15 | 2 | $0 | $0 | Jun 14, 2007 | - | - |
| 01002 | 1926.153 Liquefied Petroleum Gas (LP-Gas) OSHA citation code: 19260153 O | Serious | 1 | 1 | $1,200 | $1,200 | Jun 7, 2007 | - | - |
| 01003 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 A02 IIF | Serious | 1 | 2 | $1,200 | $1,200 | Jun 14, 2007 | - | - |
| 01004 | 1926.502 Fall Protection Systems Criteria and Practices OSHA citation code: 19260502 B03 | Serious | 1 | 3 | $4,200 | $4,200 | May 29, 2007 | - | - |
| 01005A | 1926.502 Fall Protection Systems Criteria and Practices OSHA citation code: 19260502 I03 | Serious | 3 | 3 | $4,200 | $4,200 | May 29, 2007 | - | - |
| 01005B | 1926.502 Fall Protection Systems Criteria and Practices OSHA citation code: 19260502 I04 | Serious | 3 | 3 | $0 | $0 | May 29, 2007 | - | - |
Showing the 7 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Mar 5, 2007#310649751Mar 5, 2007Planned (H) · Partial scope, Safety#310649751$29,70010 viol.10 violations$29,700 in penalties
Inspection #310649751
Dates
- Opened
- Mar 5, 2007
- Closing Conference Date
- Mar 5, 2007
- Closed
- Sep 30, 2008
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 40
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 7 serious, 3 repeat
- Initial Penalties
- $29,700
- Penalties on Record
- $29,700
- Site Address
- 990-1005 Main St., Bridgeport, CT 06604
- Industry
- 236220 Commercial and Institutional Building Construction
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (7 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.95 Criteria for Personal Protective Equipment (Construction) OSHA citation code: 19260095 A | Serious | 1 | 4 | $900 | $900 | Apr 11, 2007 | - | - |
| 01002 | 1926.153 Liquefied Petroleum Gas (LP-Gas) OSHA citation code: 19260153 J | Serious | 2 | 25 | $900 | $900 | Apr 2, 2007 | - | - |
| 01003 | 1926.153 Liquefied Petroleum Gas (LP-Gas) OSHA citation code: 19260153 H10 | Serious | 1 | 25 | $1,500 | $1,500 | Apr 2, 2007 | - | - |
| 01004 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 A02 IIF | Serious | 2 | 25 | $1,200 | $1,200 | Apr 11, 2007 | - | - |
| 01005 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 J01 I | Serious | 2 | 25 | $1,200 | $1,200 | Apr 11, 2007 | - | - |
| 01006 | 1926.501 Fall Protection - Duty to Have Fall Protection OSHA citation code: 19260501 B04 I | Serious | 2 | 25 | $4,200 | $4,200 | Mar 28, 2007 | - | - |
| 01007 | 1926.1052 Stairways (Construction) OSHA citation code: 19261052 C12 | Serious | 1 | 9 | $4,200 | $4,200 | Apr 2, 2007 | - | - |
Showing the 7 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Oct 5, 2006#109175398Oct 5, 2006Planned (H) · Partial scope, Safety#109175398$8,2506 viol.6 violations$8,250 in penalties
Inspection #109175398
Dates
- Opened
- Oct 5, 2006
- Closing Conference Date
- Oct 5, 2006
- Closed
- Nov 27, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 15
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 6 serious
- Initial Penalties
- $8,250
- Penalties on Record
- $8,250
- Site Address
- 961 Main Street, Bridgeport, CT 06604
- Industry
- 236118 Residential Remodelers
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1926.403 Electrical - General Requirements (Construction) OSHA citation code: 19260403 B02 | Serious | 1 | 4 | $750 | $750 | Jan 26, 2007 | - | - |
| 01001B | 1926.403 Electrical - General Requirements (Construction) OSHA citation code: 19260403 I02 I | Serious | 1 | 4 | $0 | $0 | Jan 26, 2007 | - | - |
| 01002A | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 B01 | Serious | 1 | 1 | $2,500 | $2,500 | Oct 5, 2006 | - | - |
| 01002B | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 E01 | Serious | 1 | 1 | $0 | $0 | Jan 11, 2007 | - | - |
| 01003 | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 G01 VII | Serious | 1 | 1 | $2,500 | $2,500 | Jan 11, 2007 | - | - |
| 01004 | 1926.501 Fall Protection - Duty to Have Fall Protection OSHA citation code: 19260501 B01 | Serious | 4 | 4 | $2,500 | $2,500 | Jan 26, 2007 | - | - |
Sep 29, 2006#310222831Sep 29, 2006Planned (H) · Partial scope, Safety#310222831$3,4507 viol.7 violations$3,450 in penalties
Inspection #310222831
Dates
- Opened
- Sep 29, 2006
- Closing Conference Date
- Sep 29, 2006
- Closed
- Apr 1, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 17
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 6 serious, 1 other-than-serious
- Initial Penalties
- $3,450
- Penalties on Record
- $3,450
- Site Address
- 990 Main St., Bridgeport, CT 06604
- Industry
- 238910 Site Preparation Contractors
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (7 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.25 Housekeeping OSHA citation code: 19260025 A | Serious | 1 | 3 | $450 | $450 | Feb 6, 2007 | - | - |
| 01002A | 1926.501 Fall Protection - Duty to Have Fall Protection OSHA citation code: 19260501 B10 | Serious | 1 | 3 | $1,500 | $1,500 | Feb 6, 2007 | - | - |
| 01002B | 1926.503 Fall Protection - Training Requirements OSHA citation code: 19260503 A01 | Serious | 1 | 3 | $0 | $0 | Feb 15, 2007 | - | - |
| 01003A | 1926.1052 Stairways (Construction) OSHA citation code: 19261052 A03 | Serious | 1 | 3 | $750 | $750 | Feb 6, 2007 | - | - |
| 01003B | 1926.1052 Stairways (Construction) OSHA citation code: 19261052 C01 | Serious | 1 | 3 | $0 | $0 | Feb 6, 2007 | - | - |
| 01004 | 1926.1053 Ladders (Construction) OSHA citation code: 19261053 B01 | Serious | 2 | 3 | $750 | $750 | Feb 6, 2007 | - | - |
| 02001 | 1910.134 Respiratory Protection OSHA citation code: 19100134 C02 II | Other | 1 | 3 | $0 | $0 | Feb 15, 2007 | - | - |
Aug 9, 2006#309997542Aug 9, 2006Complaint (B) · Partial scope, Health#309997542$2,37512 viol.12 violations$2,375 in penalties
Inspection #309997542
Dates
- Opened
- Aug 9, 2006
- Closing Conference Date
- Aug 9, 2006
- Closed
- Aug 25, 2008
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 20
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 12 serious
- Initial Penalties
- $4,750
- Penalties on Record
- $2,375
- Site Address
- 1198 Main Street, Bridgeport, CT 06604
- Industry
- 236220 Commercial and Institutional Building Construction
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 4 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 4 | 0 | mg/m³ |
| Cadmium | 4 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 4 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 4 | 0 | mg/m³ |
| Copper Fume (as Cu) | 4 | 0 | mg/m³ |
| Gravimetric DeterminationQC | 4 | 1.1435 - 4.6661 | mg/m³ |
| Iron Oxide Fume | 4 | 0 | mg/m³ |
| Lead, Inorganic (as Pb) | 4 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 4 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 4 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 4 | 0 | mg/m³ |
| Sample WeightQC | 4 | 0.118 - 1.09 | mg |
| Vanadium fume (as V2O5) | 4 | 0 | mg/m³ |
| Zinc Oxide Fume | 4 | 0 | mg/m³ |
Violations
Violation list (7 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.134 Respiratory Protection OSHA citation code: 19100134 A02 | Serious | 1 | 3 | $750 | $375 | Feb 7, 2007 | - | - |
| 01001B | 1910.134 Respiratory Protection OSHA citation code: 19100134 E01 | Serious | 1 | 3 | $0 | $0 | Feb 7, 2007 | - | - |
| 01001C | 1910.134 Respiratory Protection OSHA citation code: 19100134 F01 | Serious | 1 | 4 | $0 | $0 | Feb 7, 2007 | - | - |
| 01002A | 1910.134 Respiratory Protection OSHA citation code: 19100134 G01 IA | Serious | 1 | 1 | $750 | $375 | Feb 7, 2007 | - | - |
| 01002B | 1910.134 Respiratory Protection OSHA citation code: 19100134 G01 III | Serious | 1 | 3 | $0 | $0 | Feb 7, 2007 | - | - |
| 01002C | 1910.134 Respiratory Protection OSHA citation code: 19100134 K01 | Serious | 1 | 4 | $0 | $0 | Feb 7, 2007 | - | - |
| 01003A | 1926.1101 Asbestos (Construction) OSHA citation code: 19261101 E01 | Serious | 1 | 4 | $1,000 | $500 | Feb 22, 2007 | - | - |
Showing the 7 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
7 inspections, 2006 to 2007. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Industry comparison
Construction of Buildings, 209,213 employers with OSHA inspections. Arithmetic from DOL records.