Skip to content
SafetyRecord logoSafetyRecord
BLOSSMAN GAS OF NORTH CAROLINA, INC.
$451
penalties
10
viol.
3
insp.

BLOSSMAN GAS OF NORTH CAROLINA, INC.

3160 ASHEVILLE ROAD, WAYNESVILLE, NC 28786NAICS 454312

Inspections
3
Nov 2003 to Jul 2010 · 3 safety, 0 health
Violations
10
across 3 inspections
Penalties on record
$451
latest amounts in DOL records
By classification
Serious 4Willful 0Repeat 0Other 6

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 30, 2010FatalityAccident (A) · Partial scope, Safety#314474529$00 viol.

Inspection #314474529

Dates

Opened
Jul 30, 2010
Closing Conference Date
Sep 16, 2010
Closed
Oct 4, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10
Related Activity
1 accident

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
115 Shadow Lane, Waynesville, NC 28786
Industry
454312

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

FatalityJul 30, 2010

Employee is pinned by propane tank and is killed

Injury: AsphyxiaBody part: ChestSource: OtherEvent: Struck By
Apr 15, 2009Planned (H) · Complete scope, Safety#313054835$01 viol.

Inspection #313054835

Dates

Opened
Apr 15, 2009
Closing Conference Date
Apr 15, 2009
Closed
Apr 29, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2161 Dellwood Road, Waynesville, NC 28786
Industry
454312

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other12$0$0Apr 30, 2009--
Nov 18, 2003Planned (H) · Complete scope, Safety#307120303$4519 viol.

Inspection #307120303

Dates

Opened
Nov 18, 2003
Closing Conference Date
Nov 18, 2003
Closed
Dec 31, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
9
Violation Types
4 serious, 5 other-than-serious
Initial Penalties
$451
Penalties on Record
$451
Site Address
3160 Asheville Road, Waynesville, NC 28786
Industry
454312

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious22$188$188Dec 1, 2003--
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious12$0$0Dec 1, 2003--
01002A1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious12$263$263Dec 1, 2003--
01002B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious12$0$0Dec 1, 2003--
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Other17$0$0Dec 8, 2003--
020021910.23
Ladders
OSHA citation code: 19100023 D01 II
Other17$0$0Dec 8, 2003--
020031910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other12$0$0Dec 8, 2003--
020041910.141
Sanitation
OSHA citation code: 19100141 A04 I
Other12$0$0Dec 8, 2003--
020051910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other23$0$0Dec 8, 2003--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus2 citations · $188
1910.305Electrical - Wiring Methods, Components, and Equipment2 citations · $0
1910.37Maintenance, Safeguards, and Operational Features for Exit Routes1 citation · $0

Industry comparison

Violations per inspection
This employer3.3
Industry average1.9
Penalties per inspection
This employer$150
Industry average$1,664

NAICS 454, 2,233 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in WAYNESVILLE, NC