UNITED INDUSTRIES & CONSTRUCTION CORP.
263 PROSPECT AVENUE, BROOKLYN, NY 11215 · NAICS 236116 New Multifamily Housing Construction (except For-Sale Builders)
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Apr 12, 2023#346628878Apr 12, 2023Planned (H) · Partial scope, Health#346628878$00 viol.0 violations$0 in penalties
Inspection #346628878
Dates
- Opened
- Apr 12, 2023
- Closing Conference Date
- Apr 12, 2023
- Closed
- Sep 25, 2023
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 263 Prospect Avenue, Brooklyn, NY 11215
- Industry
- 236116 New Multifamily Housing Construction (except For-Sale Builders)
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Apr 12, 2023#346628852Apr 12, 2023Planned (H) · Partial scope, Safety#346628852$00 viol.0 violations$0 in penalties
Inspection #346628852
Dates
- Opened
- Apr 12, 2023
- Closing Conference Date
- Apr 12, 2023
- Closed
- Sep 25, 2023
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 263 Prospect Avenue, Brooklyn, NY 11215
- Industry
- 236116 New Multifamily Housing Construction (except For-Sale Builders)
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Sep 7, 2012#336288188Sep 7, 2012Follow-Up (F) · Partial scope, Safety#336288188$00 viol.0 violations$0 in penalties
Inspection #336288188
Dates
- Opened
- Sep 7, 2012
- Closing Conference Date
- Sep 7, 2012
- Closed
- Sep 13, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 5
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 2409 Avenue Z, Brooklyn, NY 11235
- Industry
- 236116 New Multifamily Housing Construction (except For-Sale Builders)
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Jun 10, 2011#315610766Jun 10, 2011Unprogrammed Related (G) · Complete scope, Safety#315610766$23,1004 viol.4 violations$23,100 in penalties
Inspection #315610766
Dates
- Opened
- Jun 10, 2011
- Closing Conference Date
- Jun 10, 2011
- Closed
- Mar 4, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 5
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 3 serious, 1 repeat
- Initial Penalties
- $23,100
- Penalties on Record
- $23,100
- Site Address
- 2409 Ave Z, Brooklyn, NY 11235
- Industry
- 236116 New Multifamily Housing Construction (except For-Sale Builders)
Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 B01 II | Serious | 1 | 5 | $3,300 | $3,300 | Nov 7, 2011 | - | - |
| 01002 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 A02 IIE | Serious | 1 | 5 | $3,300 | $3,300 | Nov 7, 2011 | - | - |
| 01003 | 1926.416 Electrical - Safety Requirements (Construction) OSHA citation code: 19260416 E01 | Serious | 1 | 5 | $3,300 | $3,300 | Oct 31, 2011 | - | - |
| 02001 | 1926.20 General Safety and Health Provisions OSHA citation code: 19260020 B02 | Repeat | 1 | 5 | $13,200 | $13,200 | Nov 7, 2011 | - | - |
Mar 1, 2011#315275206Mar 1, 2011Follow-Up (F) · Partial scope, Safety#315275206$00 viol.0 violations$0 in penalties
Inspection #315275206
Dates
- Opened
- Mar 1, 2011
- Closing Conference Date
- Mar 1, 2011
- Closed
- Mar 15, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 7011 10th Ave., Brooklyn, NY 11228
- Industry
- 236115 New Single-Family Housing Construction (except For-Sale Builders)
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Feb 10, 2011#315261271Feb 10, 2011Follow-Up (F) · Partial scope, Safety#315261271$00 viol.0 violations$0 in penalties
Inspection #315261271
Dates
- Opened
- Feb 10, 2011
- Closing Conference Date
- Feb 10, 2011
- Closed
- Feb 15, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 5
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 2409 Ave Z, Brooklyn, NY 11235
- Industry
- 236220 Commercial and Institutional Building Construction
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Apr 29, 2010#314462516Apr 29, 2010Planned (H) · Complete scope, Safety#314462516$6,0004 viol.4 violations$6,000 in penalties
Inspection #314462516
Dates
- Opened
- Apr 29, 2010
- Closing Conference Date
- Apr 30, 2010
- Closed
- Jun 26, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 5
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 2 serious, 2 repeat
- Initial Penalties
- $6,000
- Penalties on Record
- $6,000
- Site Address
- 2409 Ave Z, Brooklyn, NY 11235
- Industry
- 236220 Commercial and Institutional Building Construction
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.1053 Ladders (Construction) OSHA citation code: 19261053 B04 | Serious | 1 | 5 | $1,000 | $1,000 | Oct 4, 2010 | - | - |
| 01002 | 1926.1060 Stairways and Ladders - Training (Construction) OSHA citation code: 19261060 B | Serious | 1 | 5 | $1,000 | $1,000 | Oct 11, 2010 | - | - |
| 02001 | 1926.20 General Safety and Health Provisions OSHA citation code: 19260020 B02 | Repeat | 1 | 5 | $2,000 | $2,000 | Oct 11, 2010 | - | - |
| 02002 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 F06 | Repeat | 1 | 5 | $2,000 | $2,000 | Oct 4, 2010 | - | - |
Apr 7, 2010#314333964Apr 7, 2010Planned (H) · Complete scope, Safety#314333964$7,0005 viol.5 violations$7,000 in penalties
Inspection #314333964
Dates
- Opened
- Apr 7, 2010
- Closing Conference Date
- Apr 7, 2010
- Closed
- Nov 15, 2013
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 1
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 serious
- Initial Penalties
- $7,000
- Penalties on Record
- $7,000
- Site Address
- 7011 10th Ave., Brooklyn, NY 11228
- Industry
- 236115 New Single-Family Housing Construction (except For-Sale Builders)
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 C02 | Serious | 1 | 1 | $1,000 | $1,000 | Oct 4, 2010 | - | - |
| 01002 | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 F07 | Serious | 1 | 1 | $1,000 | $1,000 | Oct 11, 2010 | - | - |
| 01003 | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 F15 | Serious | 1 | 1 | $2,000 | $2,000 | Oct 4, 2010 | - | - |
| 01004 | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 G01 | Serious | 1 | 1 | $2,000 | $2,000 | Oct 4, 2010 | - | - |
| 01005 | 1926.454 Scaffolding - Training OSHA citation code: 19260454 A | Serious | 1 | 1 | $1,000 | $1,000 | Oct 11, 2010 | - | - |
Oct 23, 2009#313882813Oct 23, 2009Complaint (B) · Complete scope, Safety#313882813$2,2524 viol.4 violations$2,252 in penalties
Inspection #313882813
Dates
- Opened
- Oct 23, 2009
- Closing Conference Date
- Oct 23, 2009
- Closed
- May 25, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 5
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 serious
- Initial Penalties
- $3,000
- Penalties on Record
- $2,252
- Site Address
- 769 57th St., Brooklyn, NY 11220
- Industry
- 236116 New Multifamily Housing Construction (except For-Sale Builders)
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.20 General Safety and Health Provisions OSHA citation code: 19260020 B02 | Serious | 1 | 2 | $750 | $563 | Dec 29, 2009 | - | - |
| 01002 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 B01 I | Serious | 1 | 1 | $750 | $563 | Dec 21, 2009 | - | - |
| 01003 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 F06 | Serious | 1 | 1 | $750 | $563 | Dec 21, 2009 | - | - |
| 01004 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 G02 III | Serious | 1 | 1 | $750 | $563 | Dec 21, 2009 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
9 inspections, 2009 to 2023. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Construction of Buildings, 209,256 employers with OSHA inspections. Arithmetic from DOL records.