Skip to content
SafetyRecord logoSafetyRecord
UNITED INDUSTRIES & CONSTRUCTION CORP.
$38,352
penalties
17
viol.
9
insp.

UNITED INDUSTRIES & CONSTRUCTION CORP.

263 PROSPECT AVENUE, BROOKLYN, NY 11215NAICS 236116 New Multifamily Housing Construction (except For-Sale Builders)

Inspections
9
Oct 2009 to Apr 2023 · 8 safety, 1 health
Violations
17
across 9 inspections
Penalties on record
$38,352
latest amounts in DOL records
By classification
Serious 14Willful 0Repeat 3Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 12, 2023Planned (H) · Partial scope, Health#346628878$00 viol.

Inspection #346628878

Dates

Opened
Apr 12, 2023
Closing Conference Date
Apr 12, 2023
Closed
Sep 25, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
263 Prospect Avenue, Brooklyn, NY 11215
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Apr 12, 2023Planned (H) · Partial scope, Safety#346628852$00 viol.

Inspection #346628852

Dates

Opened
Apr 12, 2023
Closing Conference Date
Apr 12, 2023
Closed
Sep 25, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
263 Prospect Avenue, Brooklyn, NY 11215
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Sep 7, 2012Follow-Up (F) · Partial scope, Safety#336288188$00 viol.

Inspection #336288188

Dates

Opened
Sep 7, 2012
Closing Conference Date
Sep 7, 2012
Closed
Sep 13, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2409 Avenue Z, Brooklyn, NY 11235
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jun 10, 2011Unprogrammed Related (G) · Complete scope, Safety#315610766$23,1004 viol.

Inspection #315610766

Dates

Opened
Jun 10, 2011
Closing Conference Date
Jun 10, 2011
Closed
Mar 4, 2016

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 repeat
Initial Penalties
$23,100
Penalties on Record
$23,100
Site Address
2409 Ave Z, Brooklyn, NY 11235
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 II
Serious15$3,300$3,300Nov 7, 2011--
010021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIE
Serious15$3,300$3,300Nov 7, 2011--
010031926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Serious15$3,300$3,300Oct 31, 2011--
020011926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Repeat15$13,200$13,200Nov 7, 2011--
Mar 1, 2011Follow-Up (F) · Partial scope, Safety#315275206$00 viol.

Inspection #315275206

Dates

Opened
Mar 1, 2011
Closing Conference Date
Mar 1, 2011
Closed
Mar 15, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
7011 10th Ave., Brooklyn, NY 11228
Industry
236115 New Single-Family Housing Construction (except For-Sale Builders)

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 10, 2011Follow-Up (F) · Partial scope, Safety#315261271$00 viol.

Inspection #315261271

Dates

Opened
Feb 10, 2011
Closing Conference Date
Feb 10, 2011
Closed
Feb 15, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2409 Ave Z, Brooklyn, NY 11235
Industry
236220 Commercial and Institutional Building Construction

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Apr 29, 2010Planned (H) · Complete scope, Safety#314462516$6,0004 viol.

Inspection #314462516

Dates

Opened
Apr 29, 2010
Closing Conference Date
Apr 30, 2010
Closed
Jun 26, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 2 repeat
Initial Penalties
$6,000
Penalties on Record
$6,000
Site Address
2409 Ave Z, Brooklyn, NY 11235
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.1053
Ladders (Construction)
OSHA citation code: 19261053 B04
Serious15$1,000$1,000Oct 4, 2010--
010021926.1060
Stairways and Ladders - Training (Construction)
OSHA citation code: 19261060 B
Serious15$1,000$1,000Oct 11, 2010--
020011926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Repeat15$2,000$2,000Oct 11, 2010--
020021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Repeat15$2,000$2,000Oct 4, 2010--
Apr 7, 2010Planned (H) · Complete scope, Safety#314333964$7,0005 viol.

Inspection #314333964

Dates

Opened
Apr 7, 2010
Closing Conference Date
Apr 7, 2010
Closed
Nov 15, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1
Related Activity
1 referral

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$7,000
Penalties on Record
$7,000
Site Address
7011 10th Ave., Brooklyn, NY 11228
Industry
236115 New Single-Family Housing Construction (except For-Sale Builders)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02
Serious11$1,000$1,000Oct 4, 2010--
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F07
Serious11$1,000$1,000Oct 11, 2010--
010031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F15
Serious11$2,000$2,000Oct 4, 2010--
010041926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious11$2,000$2,000Oct 4, 2010--
010051926.454
Scaffolding - Training
OSHA citation code: 19260454 A
Serious11$1,000$1,000Oct 11, 2010--
Oct 23, 2009Complaint (B) · Complete scope, Safety#313882813$2,2524 viol.

Inspection #313882813

Dates

Opened
Oct 23, 2009
Closing Conference Date
Oct 23, 2009
Closed
May 25, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$3,000
Penalties on Record
$2,252
Site Address
769 57th St., Brooklyn, NY 11220
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Serious12$750$563Dec 29, 2009--
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious11$750$563Dec 21, 2009--
010031926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious11$750$563Dec 21, 2009--
010041926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 III
Serious11$750$563Dec 21, 2009--
Inspections 1 to 9 of 9, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements4 citations · $6,000
1926.404Electrical - Wiring Design and Protection (Construction)4 citations · $6,426
1926.20General Safety and Health Provisions3 citations · $15,763

Industry comparison

Violations per inspection
This employer1.9
Industry average1.5
Penalties per inspection
This employer$4,261
Industry average$1,290

Construction of Buildings, 209,256 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in BROOKLYN, NY

All employers in BROOKLYN →