Skip to content
SafetyRecord logoSafetyRecord
DILLON AERO, INC.
$3,000
penalties
18
viol.
2
insp.

DILLON AERO, INC.

8009 E DILLONS WAY, SCOTTSDALE, AZ 85260NAICS 332994 Small Arms, Ordnance, and Ordnance Accessories Manufacturing

Inspections
2
Feb 2012 to Feb 2012 · 1 safety, 1 health
Violations
18
across 2 inspections
Penalties on record
$3,000
latest amounts in DOL records
By classification
Serious 2Willful 0Repeat 0Other 16

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 27, 2012Referral (C) · Partial scope, Health#316395821$03 viol.

Inspection #316395821

Dates

Opened
Feb 27, 2012
Closing Conference Date
Feb 27, 2012
Closed
Apr 9, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
52
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
8009 E Dillons Way, Scottsdale, AZ 85260
Industry
332994 Small Arms, Ordnance, and Ordnance Accessories Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B09
Other13$0$0Mar 19, 2012--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C06
Other12$0$0Mar 19, 2012--
010031910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Other13$0$0Apr 6, 2012--
Feb 8, 2012Planned (H) · Complete scope, Safety#316370196$3,00015 viol.

Inspection #316370196

Dates

Opened
Feb 8, 2012
Closing Conference Date
Feb 8, 2012
Closed
Aug 15, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
49

Violations and Penalties

Total Violations
15
Violation Types
2 serious, 13 other-than-serious
Initial Penalties
$3,000
Penalties on Record
$3,000
Site Address
8009 E Dillons Way, Scottsdale, AZ 85260
Industry
332994 Small Arms, Ordnance, and Ordnance Accessories Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (15 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious15$1,250$1,250May 6, 2012--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious71$1,250$1,250Apr 18, 2012--
020011904.29
Forms
OSHA citation code: 19040029 A
Other11$500$500Apr 18, 2012--
020021910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Other15$0$0May 6, 2012--
020031910.133
Eye and Face Protection
OSHA citation code: 19100133 A03
Other11$0$0Apr 18, 2012--
020041910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other45$0$0Apr 18, 2012--
020051910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other15$0$0Apr 18, 2012--
020061910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Other15$0$0May 6, 2012--
020071910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L06
Other15$0$0May 6, 2012--
020081910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other22$0$0Apr 18, 2012--
020091910.303
Electrical - General Requirements
OSHA citation code: 19100303 F02
Other43$0$0Apr 18, 2012--
020101910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 II
Other13$0$0Apr 18, 2012--
020111910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A01 I
Other12$0$0Apr 18, 2012--
020121910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other22$0$0Apr 18, 2012--
020131910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other14$0$0May 6, 2012--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.157Portable Fire Extinguishers3 citations · $0
1910.107Spray Finishing Using Flammable and Combustible Materials2 citations · $0
1910.303Electrical - General Requirements2 citations · $0

Industry comparison

Violations per inspection
This employer9.0
Industry average3.3
Penalties per inspection
This employer$1,500
Industry average$2,307

Fabricated Metal Product Manufacturing, 47,300 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in SCOTTSDALE, AZ

All employers in SCOTTSDALE →