Inspection #317022671
ClosedThis page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
The Occupational Safety and Health Administration (OSHA) conducted a referral inspection of KOLLMANN MONUMENTAL WORKS INC at 121 Osseo Ave N, St Cloud, MN 56303 on Mar 22, 2013. The inspection scope was complete. The case was closed on Sep 10, 2014.
OSHA documented 22 violations (15 serious, 7 other-than-serious) with total penalties on record of $1,726. This inspection is linked to 1 referral in OSHA records.
This employer has 15 other OSHA inspections on record at this establishment.
- Inspection Number
- 317022671
- Type
- Referral (C)
- Scope
- Complete
- Opened
- Mar 22, 2013
- Closed
- Sep 10, 2014
- Contested
- Apr 30, 2013
- Final Order
- Aug 29, 2013
- Total Violations
- 22
- Penalties on Record
- $1,726
- Initial Penalties
- $10,625
- Related Activity
- 1 referral
- Address
- 121 Osseo Ave N, St Cloud, MN 56303
- Industry
Other OSHA inspections of the same establishment. Linked via establishment ID (exact government key).
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page.
Inspection closed Sep 10, 2014.
15 serious, 7 other-than-serious.
Citation amounts as first recorded in OSHA's penalty fields.
Latest published amounts after changes in the enforcement process.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value.
| Citation | Standard | Type | Initial | Current | Abatement |
|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 A05 | Serious | $500 | $81 | Sep 30, 2013 |
| 01002 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04I | Serious | $375 | $61 | Sep 30, 2013 |
| 01003 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C07I | Serious | $375 | $61 | Sep 30, 2013 |
| 01004 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 J02 | Serious | $625 | $102 | May 23, 2013 |
| 01005 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 J03 | Serious | $625 | $102 | May 23, 2013 |
| 01006 | 1910.184 Slings OSHA citation code: 19100184 C14 | Serious | $1,125 | $183 | May 23, 2013 |
| 01007 | 1910.184 Slings OSHA citation code: 19100184 D | Serious | $875 | $142 | May 23, 2013 |
| 01008 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | $1,750 | $284 | Sep 30, 2013 |
| 01009 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | $375 | $61 | May 23, 2013 |
| 01010 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C02I | Serious | $625 | $102 | May 23, 2013 |
| 01011 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C04I | Serious | $625 | $102 | Sep 30, 2013 |
| 01012 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | $375 | $61 | Sep 30, 2013 |
| 01013 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | $375 | $61 | Sep 30, 2013 |
| 01014 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02I | Serious | $875 | $142 | Sep 30, 2013 |
| 01015 | 5205.1210 | Serious | $375 | $61 | Sep 30, 2013 |
| 02001 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06I | Other | $0 | $0 | Sep 30, 2013 |
| 02002 | 1910.244 Other Portable Tools and Equipment OSHA citation code: 19100244 A01II | Other | $125 | $20 | May 23, 2013 |
| 02003 | 1910.244 Other Portable Tools and Equipment OSHA citation code: 19100244 A02VI | Other | $125 | $20 | May 23, 2013 |
| 02004 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01IV | Other | $125 | $20 | Sep 30, 2013 |
| 02005 | 5205067502 | Other | $125 | $20 | May 23, 2013 |
| 02006 | 5205120003 | Other | $125 | $20 | May 23, 2013 |
| 02007 | 5205120004 | Other | $125 | $20 | May 23, 2013 |
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
Data Source and Methodology
Data synced dailyData on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. On inspection pages, the status display follows the DOL inspection record first. If the DOL inspection feed includes a close date, we show the inspection as closed. If the inspection feed has no close date but all citation records tied to that inspection show a final order date, we label the page "Final Order Recorded" and disclose the citation dates instead of inferring a close date. Chemical exposure sampling data and OSHA Permissible Exposure Limits (PELs) are sourced from the OSHA Occupational Chemical Database, matched via IMIS analyte codes. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.