W & L GROUP CONSTRUCTION INC.
457 39TH STREET, BROOKLYN, NY 11232 · NAICS 236220 Commercial and Institutional Building Construction
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Aug 19, 2019#344242482Aug 19, 2019Follow-Up (F) · Partial scope, Safety#344242482$00 viol.0 violations$0 in penalties
Inspection #344242482
Dates
- Opened
- Aug 19, 2019
- Closing Conference Date
- Aug 19, 2019
- Closed
- Dec 10, 2019
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 825 39th Street, Brooklyn, NY 11232
- Industry
- 236220 Commercial and Institutional Building Construction
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Jan 18, 2019#343807970Jan 18, 2019Complaint (B) · No Inspection scope, Safety#343807970$00 viol.0 violations$0 in penalties
Inspection #343807970
Dates
- Opened
- Jan 18, 2019
- Closing Conference Date
- Jan 18, 2019
- Closed
- Feb 27, 2019
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 9
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1658 Bay Ridge Avenue, Brooklyn, NY 11204
- Industry
- 236116 New Multifamily Housing Construction (except For-Sale Builders)
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Mar 19, 2014#339638371Mar 19, 2014Referral (C) · Complete scope, Safety#339638371$8,40011 viol.11 violations$8,400 in penalties
Inspection #339638371
Dates
- Opened
- Mar 19, 2014
- Closing Conference Date
- Mar 19, 2014
- Final Order
- Apr 25, 2014
- Closed
- Sep 2, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 2
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 8 serious, 3 other-than-serious
- Initial Penalties
- $16,800
- Penalties on Record
- $8,400
- Site Address
- 457 39th Street, Brooklyn, NY 11232
- Industry
- 236117 New Housing For-Sale Builders
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (11 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 B01 | Serious | 5 | 5 | $2,800 | $1,400 | - | Apr 25, 2014 | |
| 01002 | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 E01 | Serious | 5 | 5 | $2,800 | $1,400 | - | Apr 25, 2014 | |
| 01003 | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 G01 VII | Serious | 5 | 5 | $2,800 | $1,400 | - | Apr 25, 2014 | |
| 01004A | 1926.501 Fall Protection - Duty to Have Fall Protection OSHA citation code: 19260501 B01 | Serious | 5 | 7 | $2,800 | $1,400 | - | Apr 25, 2014 | |
| 01004B | 1926.503 Fall Protection - Training Requirements OSHA citation code: 19260503 A01 | Serious | 1 | 7 | $0 | $0 | - | Apr 25, 2014 | |
| 01005A | 1926.1052 Stairways (Construction) OSHA citation code: 19261052 C01 | Serious | 4 | 5 | $2,800 | $1,400 | - | Apr 25, 2014 | |
| 01005B | 1926.1052 Stairways (Construction) OSHA citation code: 19261052 B01 | Serious | 4 | 7 | $0 | $0 | - | Apr 25, 2014 | |
| 01006 | 1926.701 Concrete and Masonry Construction - General Requirements OSHA citation code: 19260701 B | Serious | 10 | 5 | $2,800 | $1,400 | - | Apr 25, 2014 | |
| 02001 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Other | 1 | 5 | $0 | $0 | - | Apr 25, 2014 | |
| 02002 | 1910.1200 Hazard Communication OSHA citation code: 19101200 G01 | Other | 1 | 5 | $0 | $0 | - | Apr 25, 2014 | |
| 02003 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 | Other | 1 | 5 | $0 | $0 | - | Apr 25, 2014 |
Sep 19, 2012#336448204Sep 19, 2012Unprogrammed Other (J) · Complete scope, Safety#336448204$7,6004 viol.4 violations$7,600 in penalties
Inspection #336448204
Dates
- Opened
- Sep 19, 2012
- Closing Conference Date
- Sep 19, 2012
- Final Order
- May 14, 2013
- Closed
- Apr 22, 2013
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 4
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 serious
- Initial Penalties
- $7,600
- Penalties on Record
- $7,600
- Site Address
- 842 41st St., Brooklyn, NY 11232
- Industry
- 236220 Commercial and Institutional Building Construction
Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.350 Gas Welding and Cutting OSHA citation code: 19260350 A10 | Serious | 1 | 4 | $1,600 | $1,600 | - | May 14, 2013 | |
| 01002 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 B01 I | Serious | 1 | 4 | $2,000 | $2,000 | Mar 28, 2013 | - | May 14, 2013 |
| 01003 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 F06 | Serious | 1 | 4 | $2,000 | $2,000 | Mar 28, 2013 | - | May 14, 2013 |
| 01004 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 G02 IV | Serious | 1 | 4 | $2,000 | $2,000 | Mar 28, 2013 | - | May 14, 2013 |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
4 inspections, 2012 to 2019. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).