Skip to content
SafetyRecord logoSafetyRecord
F & S FRAME & TRIM, INC.
$16,243
penalties
16
viol.
3
insp.

F & S FRAME & TRIM, INC.

612 MOODY, TAMPA, FL 33609NAICS 238130 Framing Contractors

Inspections
3
Dec 2006 to Sep 2014 · 3 safety, 0 health
Violations
16
across 3 inspections
Penalties on record
$16,243
latest amounts in DOL records
By classification
Serious 13Willful 0Repeat 1Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 23, 2014Planned (H) · Partial scope, Safety#339972465$15,40011 viol.

Inspection #339972465

Dates

Opened
Sep 23, 2014
Closing Conference Date
Sep 23, 2014
Final Order
Dec 10, 2014
Closed
Jan 6, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
11
Violation Types
10 serious, 1 repeat
Initial Penalties
$30,800
Penalties on Record
$15,400
Site Address
2356 W. Hillsborough Ave, Tampa, FL 33603
Industry
238130 Framing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02
Serious42$3,080$1,540Nov 26, 2014-Dec 10, 2014
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02 I
Serious32$0$0Nov 26, 2014-Dec 10, 2014
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01
Serious22$3,080$1,540Nov 26, 2014-Dec 10, 2014
010031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious22$3,080$1,540Nov 26, 2014-Dec 10, 2014
010041926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F07
Serious52$3,080$1,540Nov 26, 2014-Dec 10, 2014
010051926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02 IV
Serious11$3,080$1,540Nov 26, 2014-Dec 10, 2014
010061926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 D15
Serious11$3,080$1,540Nov 26, 2014-Dec 10, 2014
010071926.1051
Stairways - General Requirements (Construction)
OSHA citation code: 19261051 A
Serious12$3,080$1,540Nov 26, 2014-Dec 10, 2014
01008A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious12$3,080$1,540Nov 26, 2014-Dec 10, 2014
01008B1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious11$0$0-Dec 10, 2014
020011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Repeat11$6,160$3,080Nov 26, 2014-Dec 10, 2014
Sep 9, 2008Planned (H) · Partial scope, Safety#312670516$5624 viol.

Inspection #312670516

Dates

Opened
Sep 9, 2008
Closing Conference Date
Sep 9, 2008
Closed
Oct 30, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 2 other-than-serious
Initial Penalties
$750
Penalties on Record
$562
Site Address
13015 Racetrack Rd, Tampa, FL 33626
Industry
238330 Flooring Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.102
Eye and Face Protection (Construction)
OSHA citation code: 19260102 A01
Serious12$375$281Oct 23, 2008--
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B15
Serious12$375$281Oct 23, 2008--
020011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other12$0$0Oct 23, 2008--
020021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 III
Other12$0$0Oct 23, 2008--
Dec 8, 2006Planned (H) · Partial scope, Safety#310664479$2811 viol.

Inspection #310664479

Dates

Opened
Dec 8, 2006
Closing Conference Date
Dec 8, 2006
Closed
Dec 29, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$375
Penalties on Record
$281
Site Address
612 Moody, Tampa, FL 33609
Industry
238130 Framing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.1053
Ladders (Construction)
OSHA citation code: 19261053 B13
Serious11$375$281Dec 26, 2006--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements6 citations · $7,700
1926.1053Ladders (Construction)3 citations · $1,821
1926.501Fall Protection - Duty to Have Fall Protection2 citations · $3,361

Industry comparison

Violations per inspection
This employer5.3
Industry average2.1
Penalties per inspection
This employer$5,414
Industry average$2,540

Specialty Trade Contractors, 559,382 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in TAMPA, FL