Skip to content
SafetyRecord logoSafetyRecord
MANDT CONSTRUCTION LLC
$34,129
penalties
16
viol.
3
insp.

MANDT CONSTRUCTION LLC

2125 SPRING DREAMS LN, MADISON, WI 53718NAICS 238130 Framing Contractors

Inspections
3
Jun 2006 to Jan 2023 · 3 safety, 0 health
Violations
16
across 3 inspections
Penalties on record
$34,129
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 3Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 6, 2023Planned (H) · Partial scope, Safety#346428089$19,1285 viol.

Inspection #346428089

Dates

Opened
Jan 6, 2023
Closing Conference Date
Jan 6, 2023
Final Order
Oct 5, 2023
Closed
May 29, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
5
Violation Types
4 serious, 1 other-than-serious
Initial Penalties
$19,128
Penalties on Record
$19,128
Site Address
2125 Spring Dreams Ln, Madison, WI 53718
Industry
238130 Framing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A06
Serious11$4,688$4,688Jun 15, 2023-Jun 30, 2023
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02 V
Serious11$4,688$4,688Jun 15, 2023-Jun 30, 2023
010031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious11$4,688$4,688Jun 15, 2023-Jun 30, 2023
010041926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious13$4,688$4,688Jun 15, 2023-Jun 30, 2023
020011903.19
Abatement Verification
OSHA citation code: 19030019 C01
Other11$376$376Sep 26, 2023-Oct 5, 2023
Feb 8, 2017Planned (H) · Partial scope, Safety#342088291$15,00111 viol.

Inspection #342088291

Dates

Opened
Feb 8, 2017
Closing Conference Date
Feb 8, 2017
Contested
Mar 31, 2017
Final Order
Dec 29, 2017
Closed
Jul 31, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
11
Violation Types
8 serious, 3 repeat
Initial Penalties
$30,476
Penalties on Record
$15,001
Site Address
Reston Heights Drive (site 194), Madison, WI 53718
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B01
Serious15$2,988$1,494Mar 31, 2017Mar 31, 2017Dec 29, 2017
01001B1926.21
Safety Training and Education
OSHA citation code: 19260021 B02
Serious15$0$0Mar 31, 2017Mar 31, 2017Dec 29, 2017
01001C1926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious15$0$0Mar 31, 2017Mar 31, 2017Dec 29, 2017
01001D1926.1060
Stairways and Ladders - Training (Construction)
OSHA citation code: 19261060 A
Serious15$0$0Mar 31, 2017Mar 31, 2017Dec 29, 2017
010021926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious11$1,793$897Mar 13, 2017Mar 31, 2017Dec 29, 2017
010031926.102
Eye and Face Protection (Construction)
OSHA citation code: 19260102 A01
Serious12$1,793$897Mar 13, 2017Mar 31, 2017Dec 29, 2017
010041926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious11$2,988$1,494Mar 13, 2017Mar 31, 2017Dec 29, 2017
010051926.1053
Ladders (Construction)
OSHA citation code: 19261053 B07
Serious22$2,988$1,494Mar 13, 2017Mar 31, 2017Dec 29, 2017
020011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Repeat23$8,366$4,183Mar 13, 2017Mar 31, 2017Dec 29, 2017
020021926.1053
Ladders (Construction)
OSHA citation code: 19261053 B04
Repeat11$4,780$2,390Mar 13, 2017Mar 31, 2017Dec 29, 2017
020031926.1053
Ladders (Construction)
OSHA citation code: 19261053 B09
Repeat22$4,780$2,152Mar 13, 2017Mar 31, 2017Dec 29, 2017
Jun 28, 2006Planned (H) · No Inspection scope, Safety#308385350$00 viol.

Inspection #308385350

Dates

Opened
Jun 28, 2006
Closing Conference Date
Jun 28, 2006
Closed
Jun 30, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1809 Thompson Drive, Madison, WI 53714
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.1053Ladders (Construction)4 citations · $7,530
1926.451Scaffolding - General Requirements3 citations · $14,064
1926.501Fall Protection - Duty to Have Fall Protection2 citations · $8,871

Industry comparison

Violations per inspection
This employer5.3
Industry average2.1
Penalties per inspection
This employer$11,376
Industry average$2,540

Specialty Trade Contractors, 559,279 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in MADISON, WI

All employers in MADISON →