Skip to content
SafetyRecord logoSafetyRecord
ULTIMATE DEVELOPMENT INC.
$81,636
penalties
16
viol.
2
insp.

ULTIMATE DEVELOPMENT INC.

LOT 16 CUMORAH AVE., CENTER VALLEY, PA 18034NAICS 238130 Framing Contractors

Inspections
2
Aug 2016 to Apr 2017 · 2 safety, 0 health
Violations
16
across 2 inspections
Penalties on record
$81,636
latest amounts in DOL records
By classification
Serious 11Willful 0Repeat 5Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 21, 2017Referral (C) · Partial scope, Safety#342269511$64,5337 viol.

Inspection #342269511

Dates

Opened
Apr 21, 2017
Closing Conference Date
Apr 21, 2017
Final Order
Aug 18, 2017
Closed
Apr 11, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
21
Related Activity
1 referral

Violations and Penalties

Total Violations
7
Violation Types
2 serious, 5 repeat
Initial Penalties
$64,533
Penalties on Record
$64,533
Site Address
Lot 16 Cumorah Ave., Center Valley, PA 18034
Industry
238130 Framing Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.25
Housekeeping
OSHA citation code: 19260025 A
Serious14$4,780$4,780Jul 7, 2017-Aug 18, 2017
010021926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Serious24$4,780$4,780Jul 7, 2017-Aug 18, 2017
020011926.28
Personal Protective Equipment
OSHA citation code: 19260028 A
Repeat14$9,560$9,560Jul 7, 2017-Aug 18, 2017
020021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Repeat14$27,885$27,885Jul 7, 2017-Aug 18, 2017
02003A1926.1051
Stairways - General Requirements (Construction)
OSHA citation code: 19261051 A
Repeat14$6,374$6,374Jul 7, 2017-Aug 18, 2017
02003B1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B13
Repeat11$0$0Jul 7, 2017-Aug 18, 2017
020041926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Repeat24$11,154$11,154Jul 7, 2017-Aug 18, 2017
Aug 31, 2016Referral (C) · Partial scope, Safety#341756070$17,1039 viol.

Inspection #341756070

Dates

Opened
Aug 31, 2016
Closing Conference Date
Aug 31, 2016
Final Order
Dec 1, 2016
Closed
Dec 13, 2019

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6
Related Activity
1 referral

Violations and Penalties

Total Violations
9
Violation Types
9 serious
Initial Penalties
$17,103
Penalties on Record
$17,103
Site Address
Lot 13, Center Valley, PA 18034
Industry
238130 Framing Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.28
Personal Protective Equipment
OSHA citation code: 19260028 A
Serious14$3,207$3,207-Dec 1, 2016
010021926.150
Fire Protection (Construction)
OSHA citation code: 19260150 C01 VI
Serious14$2,138$2,138-Dec 1, 2016
01003A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02 IV
Serious11$2,672$2,672-Dec 1, 2016
01003B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious11$0$0-Dec 1, 2016
010041926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious14$3,741$3,741-Dec 1, 2016
01005A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious11$3,207$3,207-Dec 1, 2016
01005B1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B05 I
Serious14$0$0-Dec 1, 2016
01005C1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B16
Serious14$0$0-Dec 1, 2016
010061926.1053
Ladders (Construction)
OSHA citation code: 19261053 B13
Serious11$2,138$2,138-Dec 1, 2016
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.1053Ladders (Construction)6 citations · $16,499
1926.28Personal Protective Equipment2 citations · $12,767
1926.451Scaffolding - General Requirements2 citations · $2,672

Industry comparison

Violations per inspection
This employer8.0
Industry average2.1
Penalties per inspection
This employer$40,818
Industry average$2,540

Specialty Trade Contractors, 559,279 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: framing contractors reported 4.6 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.8%; NAICS 23813 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in CENTER VALLEY, PA

All employers in CENTER VALLEY →