Skip to content
SafetyRecord logoSafetyRecord
REFLECTIONS GLASS & MIRROR
$5,075
penalties
9
viol.
2
insp.

REFLECTIONS GLASS & MIRROR

1218 SOUTH 4TH STREET, AMES, IA 50010NAICS 238150 Glass and Glazing Contractors

Inspections
2
Jul 2016 to May 2017 · 2 safety, 0 health
Violations
9
across 2 inspections
Penalties on record
$5,075
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 1Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 16, 2017Programmed Related (I) · Complete scope, Safety#342330610$2,0001 viol.

Inspection #342330610

Dates

Opened
May 16, 2017
Closing Conference Date
May 16, 2017
Final Order
Jul 10, 2017
Closed
Jun 30, 2017

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
1
Violation Types
1 repeat
Initial Penalties
$2,000
Penalties on Record
$2,000
Site Address
2501 Airport Dr, Ames, IA 50010
Industry
238150 Glass and Glazing Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.453
Aerial Lifts
OSHA citation code: 19260453 B02 V
Repeat11$2,000$2,000-Jul 10, 2017
Jul 25, 2016Unprogrammed Related (G) · Partial scope, Safety#341662237$3,0758 viol.

Inspection #341662237

Dates

Opened
Jul 25, 2016
Closing Conference Date
Jul 26, 2016
Final Order
Nov 28, 2016
Closed
Feb 7, 2017

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
8
Violation Types
8 serious
Initial Penalties
$6,150
Penalties on Record
$3,075
Site Address
1218 South 4th Street, Ames, IA 50010
Industry
238150 Glass and Glazing Contractors

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious14$1,050$525Jan 3, 2017-Nov 28, 2016
01001B1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 C
Serious14$0$0Jan 3, 2017-Nov 28, 2016
010021926.453
Aerial Lifts
OSHA citation code: 19260453 A02
Serious14$600$300Jan 3, 2017-Nov 28, 2016
010031926.453
Aerial Lifts
OSHA citation code: 19260453 B02 V
Serious22$1,500$750Jan 3, 2017-Nov 28, 2016
010041926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B14
Serious15$1,500$750Jan 3, 2017-Nov 28, 2016
01005A1926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious15$1,500$750Jan 3, 2017-Nov 28, 2016
01005B1926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A02
Serious15$0$0Jan 3, 2017-Nov 28, 2016
01005C1926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 B01
Serious15$0$0Jan 3, 2017-Nov 28, 2016
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.453Aerial Lifts3 citations · $3,050
1926.503Fall Protection - Training Requirements3 citations · $750
1926.501Fall Protection - Duty to Have Fall Protection2 citations · $750

Industry comparison

Violations per inspection
This employer4.5
Industry average2.1
Penalties per inspection
This employer$2,538
Industry average$2,540

Specialty Trade Contractors, 559,279 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: glass and glazing contractors reported 2.7 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 18.7%; NAICS 23815 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in AMES, IA

All employers in AMES →