Skip to content
SafetyRecord logoSafetyRecord
TRI-CITY FENCE COMPANY
$4,100
penalties
16
viol.
2
insp.

TRI-CITY FENCE COMPANY

1015 MILLENNIUM DR., KINGSPORT, TN 37663NAICS 238990 All Other Specialty Trade Contractors

Inspections
2
Jan 2025 to Nov 2025 · 2 safety, 0 health
Violations
16
across 2 inspections
Penalties on record
$4,100
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 4, 2025Planned (H) · Complete scope, Safety#348579905$01 viol.

Inspection #348579905

Dates

Opened
Nov 4, 2025
Closing Conference Date
Nov 4, 2025
Final Order
Dec 15, 2025
Closed
Feb 5, 2026

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1015 Millennium Dr., Kingsport, TN 37663
Industry
238990 All Other Specialty Trade Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.50
Medical Services and First Aid (Construction)
OSHA citation code: 19260050 C
Other11$0$0Dec 5, 2025-Dec 15, 2025
Jan 21, 2025Planned (H) · Complete scope, Safety#347988800$4,10015 viol.

Inspection #347988800

Dates

Opened
Jan 21, 2025
Closing Conference Date
Jan 21, 2025
Final Order
Mar 27, 2025
Closed
Nov 14, 2025

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
15
Violation Types
5 serious, 10 other-than-serious
Initial Penalties
$4,100
Penalties on Record
$4,100
Site Address
5015 Memorial Blvd, Kingsport, TN 37664
Industry
238990 All Other Specialty Trade Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (15 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious11$400$400Mar 20, 2025-Mar 27, 2025
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious12$800$800Mar 20, 2025-Mar 27, 2025
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious12$700$700Mar 20, 2025-Mar 27, 2025
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$800$800Mar 20, 2025-Mar 27, 2025
010051910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C03
Serious11$600$600Mar 20, 2025-Mar 27, 2025
02001TDLWD
OSHA citation code: TDLWD RULE 800-01-03-.03(27)(B)1
Other21$200$200Mar 20, 2025-Mar 27, 2025
020021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other11$0$0Mar 20, 2025-Mar 27, 2025
020031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other16$100$100Mar 20, 2025-Mar 27, 2025
020041910.178
Powered Industrial Trucks
OSHA citation code: 19100178 Q01
Other11$0$0Mar 20, 2025-Mar 27, 2025
020051910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other22$100$100Mar 20, 2025-Mar 27, 2025
020061910.303
Electrical - General Requirements
OSHA citation code: 19100303 B07
Other12$100$100Mar 20, 2025-Mar 27, 2025
020071910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 II
Other12$0$0Mar 20, 2025-Mar 27, 2025
020081910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IV A
Other12$100$100Mar 20, 2025-Mar 27, 2025
020091910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IV D
Other12$100$100Mar 20, 2025-Mar 27, 2025
020101910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other12$100$100Mar 20, 2025-Mar 27, 2025
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment4 citations · $300
1910.303Electrical - General Requirements2 citations · $200
1910.212General Requirements for All Machines (Machine Guarding)2 citations · $1,500

Industry comparison

Violations per inspection
This employer8.0
Industry average2.1
Penalties per inspection
This employer$2,050
Industry average$2,540

Specialty Trade Contractors, 559,382 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: all other specialty trade contractors reported 1.6 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.5%; NAICS 23899 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in KINGSPORT, TN

All employers in KINGSPORT →