Skip to content
SafetyRecord logoSafetyRecord
ATLANTIC BATTERY CO. INC DBA SURRETTE AMERICA
$25,280
penalties
37
viol.
4
insp.

ATLANTIC BATTERY CO. INC DBA SURRETTE AMERICA

15 PARK ST., Northfield, NH 03276

Inspections
4
May 1988 to Jan 1993 · 3 safety, 1 health
Violations
37
across 4 inspections
Penalties on record
$25,280
latest amounts in DOL records
By classification
Serious 19Willful 1Repeat 3Other 14

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 13, 1993Referral (C) · Partial scope, Health#17904111$8,2009 viol.

Inspection #17904111

Dates

Opened
Jan 13, 1993
Closing Conference Date
Apr 9, 1993
Closed
Jun 20, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
12
Related Activity
1 referral

Violations and Penalties

Total Violations
9
Violation Types
6 serious, 2 repeat, 1 other-than-serious
Initial Penalties
$8,200
Penalties on Record
$8,200
Site Address
15 Park St., Northfield, NH 03276
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Lead, Inorganic (as Pb)2419P / 5A0 - 0.12mg/m³

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Serious23$600$600May 16, 1993--
010021910.1025
Lead
OSHA citation code: 19101025 H01
Serious46$1,000$1,000May 9, 1993--
010031910.1025
Lead
OSHA citation code: 19101025 J02 I
Serious11$1,000$1,000Jun 1, 1993--
010041910.1025
Lead
OSHA citation code: 19101025 J03 IA
Serious11$1,000$1,000Jun 1, 1993--
010051910.1025
Lead
OSHA citation code: 19101025 L01 IV
Serious44$600$600Jun 1, 1993--
010061910.1025
Lead
OSHA citation code: 19101025 K01 ID
Serious11$1,000$1,000Jun 2, 1993--
02001A1910.1025
Lead
OSHA citation code: 19101025 D06 II
Repeat22$3,000$3,000Jun 1, 1993--
02001B1910.1025
Lead
OSHA citation code: 19101025 D06 III
Repeat22$0$0Jun 1, 1993--
030011910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Other32$0$0May 16, 1993--
Jan 13, 1993Follow-Up (F) · Partial scope, Safety#17903071$12,4004 viol.

Inspection #17903071

Dates

Opened
Jan 13, 1993
Closing Conference Date
Apr 9, 1993
Closed
Jun 20, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
12

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 1 willful, 1 repeat
Initial Penalties
$12,400
Penalties on Record
$12,400
Site Address
15 Park St., Northfield, NH 03276
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.303
OSHA citation code: 19100303 G02 I
Serious12$1,000$1,000May 7, 1993--
010021910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious12$1,000$1,000May 7, 1993--
020011903.16
Posting of Citations
OSHA citation code: 19030016 A
Willful17$8,400$8,400May 5, 1993--
030011910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B02 II
Repeat11$2,000$2,000May 5, 1993--
Oct 28, 1992Referral (C) · Partial scope, Safety#17902230$3,0005 viol.

Inspection #17902230

Dates

Opened
Oct 28, 1992
Closing Conference Date
Dec 4, 1992
Closed
Jun 20, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
12
Related Activity
1 referral

Violations and Penalties

Total Violations
5
Violation Types
3 serious, 2 other-than-serious
Initial Penalties
$3,000
Penalties on Record
$3,000
Site Address
15 Park St., Northfield, NH 03276
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 I
Serious12$1,000$1,000Jan 11, 1993--
010021910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C05 I
Serious12$1,000$1,000Dec 26, 1992--
010031910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C07 I
Serious12$1,000$1,000Jan 11, 1993--
020011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C05 II
Other11$0$0Dec 26, 1992--
020021910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B02 II
Other11$0$0Dec 26, 1992--

Failure to Abate Penalties4 citations, $18,000 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 4 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01001#17903071Apr 29, 1993$2,000--
01002#17903071Apr 29, 1993$10,000--
01003#17903071Apr 29, 1993$2,000--
02001#17903071Apr 29, 1993$4,000--
May 3, 1988Planned (H) · Complete scope, Safety#101337343$1,68019 viol.

Inspection #101337343

Dates

Opened
May 3, 1988
Closing Conference Date
May 4, 1988
Closed
Mar 14, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
25

Violations and Penalties

Total Violations
19
Violation Types
8 serious, 11 other-than-serious
Initial Penalties
$3,080
Penalties on Record
$1,680
Site Address
15 Park St., Northfield, NH 03276
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious33$640$320Jun 17, 1988--
010021910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious13$320$160Jun 17, 1988--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$320$160Jun 17, 1988--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E05 II
Serious12$240$120Jun 17, 1988--
010051910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious11$400$200Jun 17, 1988--
010061910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C01
Serious11$400$200Jun 17, 1988--
010071910.303
OSHA citation code: 19100303 G02 I
Serious14$280$280May 17, 1988--
010081910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious14$480$240May 17, 1988--
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other13$0$0Jun 17, 1988--
020021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Other34$0$0May 17, 1988--
020031910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 F
Other13$0$0May 17, 1988--
020041910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Other23$0$0Jun 17, 1988--

Showing the 12 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead7 citations · $7,600
1910.305Wiring methods, components, and equipment for general use5 citations · $0
1910.1200Hazard Communication4 citations · $0

Chemical exposure sampling

Samples
24
Substances
1
Inspections
1

Other inspected employers in Northfield, NH

All employers in Northfield →