Skip to content
SafetyRecord logoSafetyRecord
CAPCO INC
$62,423
penalties
149
viol.
25
insp.

CAPCO INC

1328 WINTERS AVE, GRAND JUNCTION, CO 81501

Inspections
25
Jul 1973 to Sep 2018 · 9 safety, 16 health
Violations
149
across 25 inspections
Penalties on record
$62,423
latest amounts in DOL records
By classification
Serious 88Willful 4Repeat 9Other 48

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 24, 1986Follow-Up (F) · Partial scope, Health#101590602$00 viol.

Inspection #101590602

Dates

Opened
Sep 24, 1986
Closing Conference Date
Mar 9, 1987
Closed
Apr 24, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
99

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1328 Winters Ave., Grand Junction, CO 81501
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jul 30, 1985Complaint (B) · Partial scope, Health#1501519$2,8003 viol.

Inspection #1501519

Dates

Opened
Jul 30, 1985
Closing Conference Date
Sep 5, 1985
Contested
Oct 15, 1985
Final Order
Aug 3, 1986
Closed
Oct 26, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
55
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
2 willful, 1 other-than-serious
Initial Penalties
$7,000
Penalties on Record
$2,800
Site Address
1328 Winters Ave., Grand Junction, CO 81501
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1025
Lead
OSHA citation code: 19101025 J01 III
Other11$7,000$0Aug 11, 1986Oct 15, 1985Aug 3, 1986
01001B1910.1025
Lead
OSHA citation code: 19101025 J03 IIIB
Willful1111$0$500Sep 25, 1985Oct 15, 1985Aug 3, 1986
01001C1910.1025
Lead
OSHA citation code: 19101025 J03 IIID
Willful22$0$2,300Sep 30, 1985Oct 15, 1985Aug 3, 1986

Failure to Abate Penalties2 citations, $4,000 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 2 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01001B#101590602Mar 20, 1987$2,000--
01001C#101590602Mar 20, 1987$2,000--
Jun 11, 1985Follow-Up (F) · Partial scope, Health#651265$00 viol.

Inspection #651265

Dates

Opened
Jun 11, 1985
Closing Conference Date
Jul 30, 1985
Closed
Oct 9, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
62

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1328 Winters Avenue, Grand Junction, CO 81501
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Lead, Inorganic (as Pb)8173P / 8A0 - 0.039mg/m³
Particulates not otherwise regulated (Respirable Fraction)8474P / 10A0mg/m³
May 21, 1985Referral (C) · Partial scope, Health#1515477$5001 viol.

Inspection #1515477

Dates

Opened
May 21, 1985
Closing Conference Date
May 23, 1985
Contested
Oct 4, 1985
Final Order
Aug 11, 1986
Closed
Oct 26, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
65
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 willful
Initial Penalties
$8,000
Penalties on Record
$500
Site Address
1328 Winters Ave., Grand Junction, CO 81501
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1025
Lead
OSHA citation code: 19101025 K02 I
Willful1011$8,000$500Aug 15, 1986Oct 4, 1985Aug 11, 1986

Failure to Abate Penalties1 citation, $2,000 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 1 citation issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01001#101590602Mar 20, 1987$2,000--
Feb 21, 1985Complaint (B) · Partial scope, Health#1515196$01 viol.

Inspection #1515196

Dates

Opened
Feb 21, 1985
Closing Conference Date
Feb 21, 1985
Closed
May 17, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1
Related Activity
7 complaints

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
443 Doris Road, Grand Junction, CO 81504
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
2-Butanone30 - 10.3

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Other11$0$0May 1, 1985--
Feb 20, 1985Complaint (B) · Partial scope, Health#1515188$00 viol.

Inspection #1515188

Dates

Opened
Feb 20, 1985
Closing Conference Date
Feb 20, 1985
Closed
Apr 22, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1
Related Activity
7 complaints

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
544 1/2 32 1/2 Rd, Grand Junction, CO 81501
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Feb 19, 1985Monitoring (D) · Partial scope, Health#1515212$00 viol.

Inspection #1515212

Dates

Opened
Feb 19, 1985
Closing Conference Date
Feb 21, 1985
Closed
Feb 21, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
95

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1328 Winters Ave, Grand Junction, CO 81501
Industry
Not classified in OSHA's inspection record.

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Feb 19, 1985Complaint (B) · Partial scope, Health#1515113$01 viol.

Inspection #1515113

Dates

Opened
Feb 19, 1985
Closing Conference Date
Feb 19, 1985
Closed
May 17, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1
Related Activity
3 complaints

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
3065 Goldfinch Court, Grand Junction, CO 81501
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other11$0$0May 1, 1985--
Dec 17, 1984Monitoring (D) · Partial scope, Health#1514561$1003 viol.

Inspection #1514561

Dates

Opened
Dec 17, 1984
Closing Conference Date
Jan 10, 1985
Closed
Jun 24, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
96

Violations and Penalties

Total Violations
3
Violation Types
3 repeat
Initial Penalties
$1,440
Penalties on Record
$100
Site Address
1328 Winters Ave, Grand Junction, CO 81501
Industry
Not classified in OSHA's inspection record.

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Lead, Inorganic (as Pb)6348P / 15A0 - 26mg/m³
Particulates not otherwise regulated (Respirable Fraction)6348P / 15A0mg/m³

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1025
Lead
OSHA citation code: 19101025 D02
Repeat22$1,440$100Jan 21, 1985--
01001B1910.1025
Lead
OSHA citation code: 19101025 D07
Repeat211$0$0Jan 21, 1985--
01001C1910.1025
Lead
OSHA citation code: 19101025 F02 I
Repeat34$0$0Feb 5, 1985--
Oct 22, 1984Complaint (B) · Partial scope, Health#1503051$15011 viol.

Inspection #1503051

Dates

Opened
Oct 22, 1984
Closing Conference Date
Nov 15, 1984
Closed
Jun 24, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
96
Related Activity
3 complaints

Violations and Penalties

Total Violations
11
Violation Types
5 serious, 6 repeat
Initial Penalties
$2,880
Penalties on Record
$150
Site Address
1328 Winters Ave, Grand Junction, CO 81501
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Lead, Inorganic (as Pb)6640P / 26A0 - 0.23mg/m³
Particulates not otherwise regulated (Respirable Fraction)6740P / 27A0.285mg/m³

Violations

Violation list (5 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Serious11$180$50Dec 6, 1984--
01002A1910.1025
Lead
OSHA citation code: 19101025 D07
Serious1-$900$50Nov 26, 1984--
01002B1910.1025
Lead
OSHA citation code: 19101025 K01 IC
Serious66$0$0Nov 26, 1984--
01002C1910.1025
Lead
OSHA citation code: 19101025 K01 IB
Serious1010$0$0Nov 26, 1984--
01002D1910.1025
Lead
OSHA citation code: 19101025 D01 IA
Serious11$0$0Nov 26, 1984--

Showing the 5 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Failure to Abate Penalties1 citation

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 1 citation issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01002D#1503051Dec 14, 1984---
Inspections 11 to 20 of 25, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead50 citations · $4,828
1910.119Process Safety Management of Highly Hazardous Chemicals14 citations · $33,300
1910.305Electrical - Wiring Methods, Components, and Equipment10 citations · $60

Chemical exposure sampling

Samples
592
Substances
15
Inspections
7

Sample results are listed in the record of each inspection that collected them.

Other inspected employers in GRAND JUNCTION, CO