Skip to content
SafetyRecord logoSafetyRecord
C.J. SAPORITO PLATING COMPANY
$4,500
penalties
21
viol.
1
insp.

C.J. SAPORITO PLATING COMPANY

3119 SOUTH AUSTIN AVENUE, Cicero, IL 60650

Inspections
1
Aug 1990 to Aug 1990 · 0 safety, 1 health
Violations
21
across 1 inspection
Penalties on record
$4,500
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 12

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 8, 1990Complaint (B) · Partial scope, Health#103207254$4,50021 viol.

Inspection #103207254

Dates

Opened
Aug 8, 1990
Closing Conference Date
Aug 14, 1990
Closed
Apr 30, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
131
Related Activity
1 complaint

Violations and Penalties

Total Violations
21
Violation Types
9 serious, 12 other-than-serious
Initial Penalties
$4,500
Penalties on Record
$4,500
Site Address
3119 South Austin Avenue, Cicero, IL 60650
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling17 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)60mg/m³
Beryllium and Beryllium Compounds (as Be)60mg/m³
Cadmium Fume (as Cd)60 - 0.0027mg/m³
Chromic Acid and Chromates (as CrO3)20 - 0.0093mg/m³
Chromium, Metal and Insoluble Salts60 - 0.0094mg/m³
Cobalt, Metal, Dust and Fume (as Co)60mg/m³
Copper Fume (as Cu)60 - 0.0334mg/m³
Hydrogen Chloride40 - 2.6ppm
Iron Oxide Fume60 - 0.0889mg/m³
Lead, Inorganic (as Pb)60mg/m³
Manganese Fume (as Mn)60 - 0.0068mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)60mg/m³
Nickel, Metal and Insoluble compounds (as Ni)60 - 0.0051mg/m³
Phosphoric Acid60mg/m³
Sulfuric Acid60 - 0.22mg/m³
Vanadium fume (as V2O5)60mg/m³
Zinc Oxide Fume60mg/m³

Violations

Violation list (21 of 21 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
OSHA citation code: 19100022 C
Serious37$560$560Oct 4, 1990--
010021910.94
Ventilation
OSHA citation code: 19100094 D09 V
Serious25$560$560Sep 12, 1990--
010031910.94
Ventilation
OSHA citation code: 19100094 D09 VII
Serious112$640$640Oct 4, 1990--
010041910.94
Ventilation
OSHA citation code: 19100094 D10
Serious110$810$810Oct 4, 1990--
010051910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious59$640$640Oct 4, 1990--
01006A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L
Serious14$480$480Oct 4, 1990--
01006B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Serious14$0$0Oct 4, 1990--
01006C1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 Q07
Serious14$0$0Oct 4, 1990--
010071910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious2120$810$810Sep 18, 1990--
020011910.94
Ventilation
OSHA citation code: 19100094 D09 VIII
Other12$0$0Sep 18, 1990--
020021910.94
Ventilation
OSHA citation code: 19100094 D09 XI
Other120$0$0Sep 11, 1990--
020031910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Other12$0$0Oct 4, 1990--
020041910.134
Respiratory Protection
OSHA citation code: 19100134 B11
Other11$0$0Oct 4, 1990--
020051910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04
Other19$0$0Oct 4, 1990--
020061910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other1120$0$0Sep 11, 1990--
020071910.303
OSHA citation code: 19100303 C
Other17$0$0Sep 7, 1990--
020081910.304
Wiring design and protection
OSHA citation code: 19100304 F05 V
Other17$0$0Sep 7, 1990--
020091910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 A02 I
Other11$0$0Sep 11, 1990--
020101910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Other217$0$0Sep 7, 1990--
020111910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 J02 II
Other18$0$0Sep 18, 1990--
020121910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other1120$0$0Oct 4, 1990--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.94Ventilation5 citations · $2,010
1910.178Powered Industrial Trucks3 citations · $480
1910.305Wiring methods, components, and equipment for general use3 citations · $0

Chemical exposure sampling

Samples
96
Substances
17
Inspections
1

Other inspected employers in Cicero, IL