Skip to content
SafetyRecord logoSafetyRecord
COVENANT STEEL WAREHOUSE, INC.
$6,950
penalties
15
viol.
9
insp.

COVENANT STEEL WAREHOUSE, INC.

4528 WEST GATE PARKWAY, DOTHAN, AL 36303NAICS 332312 Fabricated Structural Metal Manufacturing

Inspections
9
Sep 1999 to Feb 2022 · 6 safety, 3 health
Violations
15
across 9 inspections
Penalties on record
$6,950
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 0Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 24, 2022Planned (H) · Complete scope, Safety#345804835$02 viol.

Inspection #345804835

Dates

Opened
Feb 24, 2022
Closing Conference Date
Feb 25, 2022
Final Order
Apr 28, 2022
Closed
Apr 11, 2022

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
4528 West Gate Parkway, Dothan, AL 36303
Industry
331221 Rolled Steel Shape Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Other123$0$0-Apr 28, 2022
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IV
Other123$0$0Apr 14, 2022-Apr 28, 2022
Jun 2, 2021Planned (H) · Partial scope, Health#345339790$00 viol.

Inspection #345339790

Dates

Opened
Jun 2, 2021
Closing Conference Date
Jul 6, 2021
Closed
Nov 15, 2021

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
85

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4528 West Gate Parkway, Dothan, AL 36303
Industry
331221 Rolled Steel Shape Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Dec 3, 2014Planned (H) · Partial scope, Safety#340122555$1,7502 viol.

Inspection #340122555

Dates

Opened
Dec 3, 2014
Closing Conference Date
Dec 3, 2014
Final Order
Feb 17, 2015
Closed
Feb 25, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
95

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$3,000
Penalties on Record
$1,750
Site Address
4528 Westgate Parkway, Dothan, AL 36303
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 G01 V
Serious15$3,000$1,750Feb 3, 2015-Feb 17, 2015
020011910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Other12$0$0Feb 6, 2015-Feb 17, 2015
Feb 19, 2008Referral (C) · Partial scope, Health#311752521$00 viol.

Inspection #311752521

Dates

Opened
Feb 19, 2008
Closing Conference Date
Feb 22, 2008
Closed
Mar 12, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
82
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4528 Westgate Parkway, Dothan, AL 36303
Industry
332312 Fabricated Structural Metal Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Jan 24, 2008Planned (H) · Partial scope, Safety#311612220$3,5755 viol.

Inspection #311612220

Dates

Opened
Jan 24, 2008
Closing Conference Date
Jan 24, 2008
Closed
Mar 27, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
80

Violations and Penalties

Total Violations
5
Violation Types
4 serious, 1 other-than-serious
Initial Penalties
$7,425
Penalties on Record
$3,575
Site Address
4528 Westgate Parkway, Dothan, AL 36303
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.29
Fall Protection Systems and Criteria
OSHA citation code: 19100029 A03 VII
Serious11$4,500$1,625Feb 25, 2008--
010021910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B02 III
Serious103$1,300$975Feb 29, 2008--
01003A1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 F02 I
Serious33$1,625$975Feb 27, 2008--
01003B1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 F02 IV
Serious13$0$0Feb 27, 2008--
020011904.29
Forms
OSHA citation code: 19040029 B01
Other66$0$0Feb 29, 2008--
Oct 12, 2004Planned (H) · Partial scope, Safety#307832733$6251 viol.

Inspection #307832733

Dates

Opened
Oct 12, 2004
Closing Conference Date
Oct 12, 2004
Closed
Dec 2, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
75

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$1,125
Penalties on Record
$625
Site Address
4528 Westgate Parkway, Dothan, AL 36303
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious23$1,125$625Nov 3, 2004--
Nov 4, 2003Planned (H) · Complete scope, Safety#307148569$02 viol.

Inspection #307148569

Dates

Opened
Nov 4, 2003
Closing Conference Date
Nov 4, 2003
Closed
Jan 12, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
36

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
4528 Westgate Parkway, Dothan, AL 36303
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B02
Other12$0$0Jan 7, 2004--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other11$0$0Jan 5, 2004--
Aug 12, 2003Planned (H) · Complete scope, Health#306445289$1,0003 viol.

Inspection #306445289

Dates

Opened
Aug 12, 2003
Closing Conference Date
Aug 13, 2003
Closed
Mar 9, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 other-than-serious
Initial Penalties
$1,000
Penalties on Record
$1,000
Site Address
4528 Westgate Parkway, Dothan, AL 36303
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling17 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
2-Pentanone30 - 0.335694ppm
Antimony and Compounds (as Sb)40mg/m³
Beryllium and Beryllium Compounds (as Be)40mg/m³
Cadmium40mg/m³
Chromium, Metal and Insoluble Salts40mg/m³
Cobalt, Metal, Dust and Fume (as Co)40mg/m³
Copper Fume (as Cu)40.0062442 - 0.0182606mg/m³
Ethyl Benzene31.5927867 - 5.5594878ppm
Gravimetric DeterminationQC43.5425 - 15.8738mg/m³
Iron Oxide Fume41.8075 - 6.6625814mg/m³
Lead, Inorganic (as Pb)40mg/m³
Manganese Fume (as Mn)40.1125118 - 1.1442925mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40mg/m³
Particulates not otherwise regulated (Total Dust)43.5425 - 15.8738mg/m³
Sample WeightQC43.004 - 13.461mg
Vanadium fume (as V2O5)40mg/m³
Xylene36.5791206 - 22.7558136ppm
Zinc Oxide Fume40mg/m³

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IIB2
Serious14$1,000$1,000Mar 12, 2004--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 B10
Other11$0$0Jan 9, 2004--
020021910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Other31$0$0Dec 22, 2003--
Sep 8, 1999Complaint (B) · Partial scope, Safety#302615620$00 viol.

Inspection #302615620

Dates

Opened
Sep 8, 1999
Closing Conference Date
Sep 8, 1999
Closed
Oct 6, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
54
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4528 Westgate Parkway, Dothan, AL 36303
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Inspections 1 to 9 of 9, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1030Bloodborne Pathogens2 citations · $975
1910.305Electrical - Wiring Methods, Components, and Equipment2 citations · $0
1910.37Maintenance, Safeguards, and Operational Features for Exit Routes1 citation · $0

Chemical exposure sampling

Samples
73
Substances
19
Inspections
1

Industry comparison

Violations per inspection
This employer1.7
Industry average3.3
Penalties per inspection
This employer$772
Industry average$2,301

Fabricated Metal Product Manufacturing, 45,892 employers with OSHA inspections. Arithmetic from DOL records.