DEPT. OF THE TREASURY - U.S. MINT
ROUTE 218, West Point, NY 10996
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
May 12, 1994#108807967May 12, 1994Referral (C) · Partial scope, Health#108807967$012 viol.12 violations$0 in penalties
Inspection #108807967
Dates
- Opened
- May 12, 1994
- Closing Conference Date
- Jun 22, 1994
- Closed
- Jun 26, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 200
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 8 serious, 1 willful, 3 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Route 218, West Point, NY 10996
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Chemical Exposure Sampling8 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 109P / 1A | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 109P / 1A | 0 | mg/m³ |
| Cadmium | 109P / 1A | 0 - 0.0091 | mg/m³ |
| Copper Fume (as Cu) | 109P / 1A | 0 | mg/m³ |
| Lead, Inorganic (as Pb) | 109P / 1A | 0 - 0.0065 | mg/m³ |
| Silver, Metal and Soluble Compounds (as Ag) | 109P / 1A | 0 - 0.0015 | mg/m³ |
| Tin, inorganic compounds (except oxides) (as Sn) | 109P / 1A | 0 | mg/m³ |
| Zinc Oxide Fume | 109P / 1A | 0 - 0.0139 | mg/m³ |
Violations
Violation list (12 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.132 General requirements OSHA citation code: 19100132 A | Serious | 1 | 4 | $0 | $0 | Sep 6, 1994 | - | - |
| 01002 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 1 | 4 | $0 | $0 | Sep 6, 1994 | - | - |
| 01003 | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 C01 | Serious | 1 | 4 | $0 | $0 | Sep 16, 1994 | - | - |
| 01004 | 1910.303 OSHA citation code: 19100303 B01 | Serious | 1 | 5 | $0 | $0 | Oct 1, 1994 | - | - |
| 01005 | 1910.1027 Cadmium OSHA citation code: 19101027 D01 I | Serious | 5 | 5 | $0 | $0 | Sep 1, 1994 | - | - |
| 01006 | 1910.1027 Cadmium OSHA citation code: 19101027 M04 | Serious | 5 | 5 | $0 | $0 | Oct 24, 1994 | - | - |
| 02001 | 1910.120 Hazardous Waste Operations and Emergency Response OSHA citation code: 19100120 Q01 | Serious | 1 | 3 | $0 | $0 | Jan 30, 1995 | - | - |
| 02003 | 1910.1450 Occupational Exposure to Hazardous Chemicals in Laboratories OSHA citation code: 19101450 E01 | Willful | 1 | 4 | $0 | $0 | Oct 24, 1994 | - | - |
| 02004 | 1910.1450 Occupational Exposure to Hazardous Chemicals in Laboratories OSHA citation code: 19101450 F01 | Serious | 1 | 4 | $0 | $0 | Oct 24, 1994 | - | - |
| 03001 | 1910.20 OSHA citation code: 19100020 G01 I | Other | 1 | 7 | $0 | $0 | Sep 16, 1994 | - | - |
| 03002 | 1910.20 OSHA citation code: 19100020 G01 II | Other | 1 | 7 | $0 | $0 | Sep 16, 1994 | - | - |
| 03003 | 1910.20 OSHA citation code: 19100020 G01 III | Other | 1 | 7 | $0 | $0 | Sep 16, 1994 | - | - |
May 4, 1994#108807082May 4, 1994Planned (H) · Complete scope, Safety#108807082$040 viol.40 violations$0 in penalties
Inspection #108807082
Dates
- Opened
- May 4, 1994
- Closing Conference Date
- Jun 10, 1994
- Closed
- Jun 14, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 200
Violations and Penalties
- Total Violations
- 40
- Violation Types
- 29 serious, 2 willful, 9 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Route 218, West Point, NY 10996
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (25 of 40 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 OSHA citation code: 19100022 A02 | Serious | 1 | 3 | $0 | $0 | Aug 23, 1994 | - | - |
| 01002 | 1910.22 OSHA citation code: 19100022 A03 | Serious | 1 | 10 | $0 | $0 | Aug 23, 1994 | - | - |
| 01003 | 1910.23 OSHA citation code: 19100023 C01 | Serious | 1 | 2 | $0 | $0 | Aug 23, 1994 | - | - |
| 01004 | 1910.36 OSHA citation code: 19100036 B06 | Serious | 2 | 45 | $0 | $0 | Aug 23, 1994 | - | - |
| 01005 | 1910.36 OSHA citation code: 19100036 B07 | Serious | 1 | 200 | $0 | $0 | Aug 23, 1994 | - | - |
| 01006 | 1910.36 OSHA citation code: 19100036 B08 | Serious | 1 | 200 | $0 | $0 | May 30, 1995 | - | - |
| 01007 | 1910.37 OSHA citation code: 19100037 H01 | Serious | 1 | 200 | $0 | $0 | Aug 23, 1994 | - | - |
| 01008 | 1910.37 OSHA citation code: 19100037 Q01 | Serious | 8 | 200 | $0 | $0 | Aug 8, 1994 | - | - |
| 01009 | 1910.106 OSHA citation code: 19100106 D02 I | Serious | 1 | 3 | $0 | $0 | Jul 31, 1994 | - | - |
| 01010 | 1910.132 General requirements OSHA citation code: 19100132 A | Serious | 2 | 13 | $0 | $0 | Aug 8, 1994 | - | - |
| 01011 | 1910.137 Electrical Protective Equipment OSHA citation code: 19100137 B02 VIII | Serious | 1 | 2 | $0 | $0 | Aug 23, 1994 | - | - |
| 01012 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 5 | $0 | $0 | Jul 26, 1994 | - | - |
| 01013 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 D01 | Serious | 2 | 13 | $0 | $0 | Aug 23, 1994 | - | - |
| 01014 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 J02 III | Serious | 1 | 7 | $0 | $0 | Jul 31, 1994 | - | - |
| 01015 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 J02 IV | Serious | 1 | 7 | $0 | $0 | Jul 31, 1994 | - | - |
| 01016 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 B03 | Serious | 1 | 3 | $0 | $0 | Aug 23, 1994 | - | - |
| 01017 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H04 | Serious | 1 | 3 | $0 | $0 | Aug 23, 1994 | - | - |
| 01018 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B07 III | Serious | 2 | 8 | $0 | $0 | Jul 26, 1994 | - | - |
| 01019 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 D06 I | Serious | 1 | 13 | $0 | $0 | Aug 23, 1994 | - | - |
| 01020 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 D09 IV | Serious | 1 | 5 | $0 | $0 | Jul 26, 1994 | - | - |
| 01022 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 M02 I | Serious | 1 | 4 | $0 | $0 | Aug 23, 1994 | - | - |
| 01023 | 1910.304 Wiring design and protection OSHA citation code: 19100304 A02 | Serious | 1 | 1 | $0 | $0 | Aug 8, 1994 | - | - |
| 01024 | 1910.304 Wiring design and protection OSHA citation code: 19100304 D02 II | Serious | 1 | 8 | $0 | $0 | Jul 31, 1994 | - | - |
| 01025 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 B01 | Serious | 1 | 10 | $0 | $0 | Aug 8, 1994 | - | - |
| 01026 | 1910.332 Electrical Safety-Related Work Practices - Training OSHA citation code: 19100332 B01 | Serious | 1 | 10 | $0 | $0 | Oct 21, 1994 | - | - |
Showing the 25 violations listed first by citation identifier. This inspection has 40 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
2 inspections, 1994 to 1994. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.